Name: | ZIMMERMAN FRAMING COMPANY, INC. |
Jurisdiction: | Idaho |
Legal type: | General Business Corporation (D) |
Status: | Active-Good Standing |
Date of registration: | 05 Jan 2001 (24 years ago) |
Financial Date End: | 31 Jan 2026 |
Entity Number: | 418440 |
Place of Formation: | IDAHO |
File Number: | 418440 |
ZIP code: | 83858 |
County: | Kootenai County |
Mailing Address: | 1562 W LARAMIE AVE RATHDRUM, ID 83858-8707 |
Name | Role | Address |
---|---|---|
JACK ZIMMERMAN | Agent | 1562 W LARAMIE AVE, RATHDRUM, ID 83858 |
Name | Role | Address | Appointed On |
---|---|---|---|
Jack L Zimmerman | President | 1562 WEST LARAMIE AVE, RATHDRUM, ID 83858 | 2020-12-12 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0006022049 | 2024-12-12 |
Annual Report | 0005494951 | 2023-12-03 |
Annual Report | 0005056046 | 2023-01-06 |
Annual Report | 0004559422 | 2022-01-09 |
Annual Report Amendment | 0004184822 | 2021-02-27 |
Annual Report | 0004098950 | 2020-12-12 |
Application for Reinstatement | 0003880049 | 2020-05-19 |
Dissolution/Revocation - Administrative | 0003839403 | 2020-04-08 |
Annual Report | 0003417926 | 2019-01-30 |
Application for Reinstatement | 0002785975 | 2018-05-23 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342511854 | 1032500 | 2017-07-26 | 6535 N. GAVIN LOOP, COEUR D ALENE, ID, 83815 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1247207 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2017-08-15 |
Abatement Due Date | 2017-09-11 |
Current Penalty | 2000.0 |
Initial Penalty | 3803.0 |
Final Order | 2017-10-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to lacerations and amputation hazards: (a) On or about July 26, 2017, and at times prior thereto, employees were permitted to use handheld circular saws to cut materials while resting the work piece on the worker's toes and leaning it against the worker's legs. Note: Abatement certification AND documentation are required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260021 B02 |
Issuance Date | 2017-08-15 |
Abatement Due Date | 2017-09-11 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-10-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. (a) On or about July 26, 2017, and at times prior thereto, employees were permitted to use a circular skilsaw to cut materials while resting the work piece on their toes and leaning it against their shins exposing himself to potential amputation hazards. Note: Abatement certification AND documentation are required for this item. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-08-15 |
Abatement Due Date | 2017-09-11 |
Current Penalty | 2000.0 |
Initial Penalty | 3803.0 |
Final Order | 2017-10-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On or about July 26, 2017, and at times prior thereto, employees observed setting trusses and walking on the exterior top place without using any means of fall protection and exposed to a 20 foot fall hazards. Note: Abatement certification AND documentation are required for this item. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260503 A02 III |
Issuance Date | 2017-08-15 |
Abatement Due Date | 2017-09-11 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-10-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: (a) On or about July 2017, and at times prior thereto, the responsible person on site and employees performing framing activities did not recognize the hazards of working without fall protection and/or take appropriate actions to minimize and/or eliminate these hazards. They were not familiar with how to correctly use fall protection. Note: Abatement certification AND supporting documentation are required for this item. |
Date of last update: 07 Apr 2025
Sources: Idaho Secretary of State