Search icon

CUTTING EDGE MANUFACTURING, INC.

Company Details

Name: CUTTING EDGE MANUFACTURING, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Inactive-Dissolved
Date of registration: 02 Jan 2001 (24 years ago)
Financial Date End: 31 Jan 2019
Date dissolved: 17 Jan 2019
Entity Number: 418151
Place of Formation: IDAHO
File Number: 418151
ZIP code: 83687
County: Canyon County
Mailing Address: 425 N KINGS RD NAMPA, ID 83687

Agent

Name Role Address
JAMES R DRAKE Agent 425 N KINGS RD, NAMPA, ID 83687

Filing

Filing Name Filing Number Filing date
Articles of Dissolution 0003400616 2019-01-17
Annual Report 0002784852 2017-12-02
Annual Report 0002784851 2016-12-03
Annual Report 0002784850 2015-11-22
Annual Report 0002784849 2014-11-22
Annual Report 0002784862 2013-12-08
Annual Report 0002784861 2012-11-11
Annual Report 0002784857 2011-11-05
Annual Report 0002784856 2010-12-15
Annual Report 0002784855 2010-01-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340792571 1032500 2015-07-21 425 N KINGS RD, NAMPA, ID, 83687
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-07-22
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2015-08-31

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2015-08-10
Abatement Due Date 2015-09-25
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. a) In the manufacturing area, on or about July 22, 2015 or prior thereto: Employees were operating a Kalamazoo Startrite 24-T-10 Vertical Band Saw to cut aluminum pieces of up to 1 inch in width. During this operation, 10 inches of the saw blade were unguarded. Employees were exposed to the hazard of contacting the portion of the moving saw blade not directly involved with the point of operation. Abatement certification is required for this item.
Citation ID 02001A
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2015-08-10
Abatement Due Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-31
Nr Instances 2
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): The employer determined that voluntary respirator use is permissible, and the employer did not provide respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard"). a) Manufacturing Area, on or about July 22, 2015 or prior thereto: The employer provided 3M Model 8511 N95 respirators to employees and had not provided Appendix D of 29 CFR 1910.134. b) Manufacturing Area, on or about July 22, 2015 or prior thereto: The employer provided an AO Safety elastomeric half-face respirator to employees and had not provided Appendix D of 29 CFR 1910.134. Abatement certification is required for this item.
Citation ID 02001B
Citaton Type Other
Standard Cited 19100134 C02 II
Issuance Date 2015-08-10
Abatement Due Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written respiratory protection program to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks). a) Manufacturing Area, on or about July 22, 2015 or prior thereto: The employer provided an AO Safety half-face elastomeric organic vapor cartridge respirator to employees and had not established a respiratory protection program. The respirator was worn during the machining of plastic to filter nuisance odors. The respirator was not stored in a sanitary manner. Abatement certification is required for this item.
Citation ID 02001C
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2015-08-10
Abatement Due Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. a) Manufacturing Area, on or about July 22, 2015 or prior thereto: The employer provided an AO Safety elastomeric half-face respirator to employees and had not conducted medical evaluations for these employees. Abatement certification is required for this item.
Citation ID 02002
Citaton Type Other
Standard Cited 19100147 C01
Issuance Date 2015-08-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) Manufacturing Area, on or about July 22, 2015 or prior thereto: The employer had not established energy control procedures for the 230 Volt Cosen horizontal band saw, Model AH-260C-02, Serial #C920505. Blade changing is performed on the saw on a quarterly basis. This item was corrected during the inspection.
Citation ID 02003
Citaton Type Other
Standard Cited 19100215 B09
Issuance Date 2015-08-10
Abatement Due Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. a) Manufacturing Area, on or about July 22, 2015 or prior thereto: A 6" bench grinder, model BG150AUL, had its exterior guard 3/8" from the abrasive wheel, and was missing a tongue guard. Abatement certification is required for this item.
Citation ID 02004
Citaton Type Other
Standard Cited 19100242 B
Issuance Date 2015-08-10
Abatement Due Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. a) Manufacturing Area, on or about July 22, 2015: An airline used for cleaning purposes on the Haas CNC Mill VF3 was measured at 100 PSI. Abatement certification is required for this item.
Citation ID 02005
Citaton Type Other
Standard Cited 19100303 G01 I A
Issuance Date 2015-08-10
Abatement Due Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1)(i)(A): The depth of the working space in the direction of access to live parts was less than indicated in Table S-1. a) Manufacturing Area, on or about July 22, 2015 or prior thereto: The working space in front of the circuit breaker panels for the facility were limited to 12". A pallet was stored in front of the panels. Abatement certification is required for this item.

Date of last update: 07 Apr 2025

Sources: Idaho Secretary of State