Name: | SILVERADO CONSTRUCTION, INC. |
Jurisdiction: | Idaho |
Legal type: | General Business Corporation (D) |
Status: | Active-Good Standing |
Date of registration: | 13 Nov 2000 (24 years ago) |
Financial Date End: | 30 Nov 2025 |
Entity Number: | 416210 |
Place of Formation: | IDAHO |
File Number: | 416210 |
ZIP code: | 83554 |
County: | Idaho County |
Mailing Address: | CINDY TOMLINSON 251 DOUMECQ RD WHITE BIRD, ID 83554-5018 |
Name | Role | Address |
---|---|---|
MICHAEL R TOMLINSON | Agent | 251 DOUMECQ RD, WHITE BIRD, ID 83554 |
Name | Role | Address | Appointed On |
---|---|---|---|
Cindy C Tomlinson | President | 251 DOUMECQ RD, WHITE BIRD, ID 83554 | 2020-10-03 |
Name | Role | Address | Appointed On | Resigned On |
---|---|---|---|---|
Michael R Tomlinson | Vice President | 251 DOUMECQ RD, WHITE BIRD, ID 83554-5018 | 2023-10-09 | 2023-10-09 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005920708 | 2024-10-03 |
Annual Report | 0005435759 | 2023-10-09 |
Annual Report | 0004953872 | 2022-10-15 |
Annual Report | 0004436988 | 2021-10-04 |
Annual Report | 0004021132 | 2020-10-03 |
Annual Report | 0003642137 | 2019-10-06 |
Annual Report | 0003341085 | 2018-10-31 |
Annual Report | 0002777417 | 2017-10-04 |
Annual Report | 0002777416 | 2016-10-31 |
Annual Report | 0002777414 | 2015-10-14 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343021267 | 1032500 | 2018-03-15 | 4909 ELISNORE AVENUE, MERIDIAN, ID, 83642 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1310456 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1302125 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1302128 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2018-05-29 |
Abatement Due Date | 2018-06-22 |
Current Penalty | 1178.0 |
Initial Penalty | 2356.0 |
Final Order | 2018-06-14 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) On or about March 15, 2018 and at times prior thereto employees were installing windows with an impact driver where no eye protection was worn. NOTE-Abatement certification is required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2018-05-29 |
Abatement Due Date | 2018-06-22 |
Current Penalty | 1413.5 |
Initial Penalty | 2827.0 |
Final Order | 2018-06-14 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated a) On or about March 15, 2018 and at times prior thereto employees were working from an aerial lift 13 feet high, with no lanyard connecting their harness to the aerial lift basket. NOTE-Abatement certification is required for this item. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2018-05-29 |
Abatement Due Date | 2018-06-22 |
Current Penalty | 1413.5 |
Initial Penalty | 2827.0 |
Final Order | 2018-06-14 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about March 15, 2018 and at times prior thereto employees were installing windows on the second floor exposed to fall hazards of 13 feet from an open and unguarded window opening. b) On or about March 15, 2018 and at times prior thereto an employee, who was installing windows, exited his aerial lift onto the roof 13 feet high with no fall protection. NOTE-Abatement certification is required for this item. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260503 B01 |
Issuance Date | 2018-05-29 |
Abatement Due Date | 2018-06-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-06-14 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record. a) On or about March 15, 2018 and at times prior thereto the employer did not verify that employees were trained in accordance with 29 CFR 1926.503(a) by preparing or maintaining a written certification of fall protection training. NOTE-Abatement certification is required for this item. |
Inspection Type | Unprog Rel |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2007-10-02 |
Case Closed | 2007-12-06 |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2007-11-02 |
Abatement Due Date | 2007-11-07 |
Current Penalty | 300.0 |
Initial Penalty | 600.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 02 |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2007-11-02 |
Abatement Due Date | 2007-11-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 02 |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2007-11-02 |
Abatement Due Date | 2007-11-07 |
Current Penalty | 300.0 |
Initial Penalty | 600.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 02 |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2007-11-02 |
Abatement Due Date | 2007-11-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 02 |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2007-05-30 |
Emphasis | S: RESIDENTIAL CONSTR |
Case Closed | 2007-07-13 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260300 B01 |
Issuance Date | 2007-06-27 |
Abatement Due Date | 2007-07-10 |
Current Penalty | 300.0 |
Initial Penalty | 300.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 02 |
Date of last update: 07 Apr 2025