343711123
|
1032500
|
2019-01-09
|
303 W PENNWOOD ST., MERIDIAN, ID, 83642
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-01-11
|
Emphasis |
L: FALL
|
Case Closed |
2019-09-04
|
Related Activity
Type |
Complaint |
Activity Nr |
1406699 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1387031 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1371116 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1370805 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260502 B01 |
Issuance Date |
2019-05-07 |
Abatement Due Date |
2019-06-03 |
Current Penalty |
0.0 |
Initial Penalty |
3978.0 |
Final Order |
2019-06-07 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) Jobsite: On or about January 9, 2019, and at times prior thereto; top rails on second and third floor balconies were measured at 46-48 inches. Note* Abatement certification AND documentation is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260502 B03 |
Issuance Date |
2019-05-07 |
Abatement Due Date |
2019-06-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-06-07 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: a) Jobsite: On or about January 9, 2019, and at times prior thereto; Second and third floor balcony guarding systems were found not fully secured, exposing framers to trips and falls from 10-20 feet. Note* Abatement certification AND documentation is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-05-07 |
Current Penalty |
3000.0 |
Initial Penalty |
4546.0 |
Final Order |
2019-06-07 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Jobsite: On or about January 9, 2019 and at times prior thereto; an employee was installing sheathing on truss framework without a fall protection system in place, exposing employee to falls from 6-8 feet to asphalt ground. b) Jobsite: On or about January 9, 2019, and at times prior thereto; Second and third floor balcony guardrails were missing, which exposed framers to 10-20 foot falls during framing activities. Note* Abatement certification is required for this item. Betania Framing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1198833, citation number 1, item number 1a and was affirmed as a final order on January 31, 2017, with respect to a workplace located at 6101 Birch Lane, Nampa, ID 83605. |
|
|
341988335
|
1032500
|
2016-12-21
|
6101 BIRCH LANE, NAMPA, ID, 83687
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-12-21
|
Emphasis |
L: FALL, N: CTARGET, P: CTARGET
|
Case Closed |
2017-02-06
|
Related Activity
Type |
Inspection |
Activity Nr |
1198814 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-12-27 |
Abatement Due Date |
2017-01-03 |
Current Penalty |
1336.0 |
Initial Penalty |
2672.0 |
Final Order |
2017-01-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a) Jobsite: On December 22, 2016 and at times prior thereto an employee performed framing activities on the exterior top plate. The employee straddled the top plate without a fall protection system in place. b) Jobsite: On December 22, 2016 and at times prior thereto employees performed framing activities on the second floor with open sided floors. Guardrails were not in place at the front or back of the second floor. Note) Certification of corrective action is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2016-12-27 |
Abatement Due Date |
2017-01-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-01-31 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used; a) Jobsite: On December 21, 2016 and at times prior thereto employees did not recognize or acknowledge the hazard of working from the exterior top plate. No action was taken to correct or minimize the hazard. b) Jobsite: On December 21, 2016 and at times prior thereto employees did not recognize or acknowledge the hazard of working near an open sided floor. No action was taken to correct or minimize the hazard. Note) Certification of corrective action IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2016-12-27 |
Abatement Due Date |
2017-01-03 |
Current Penalty |
802.0 |
Initial Penalty |
1604.0 |
Final Order |
2017-01-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Jobsite: On December 22, 2016 and at times prior thereto an employee performing framing activities stood on the top cap of a six foot self-supporting ladder. Note) Certification of corrective action is required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261060 A |
Issuance Date |
2016-12-27 |
Abatement Due Date |
2017-01-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-01-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways that would enable each employee to recognize hazards related to ladders and stairways, and train each employee in the procedures to be followed to minimize these hazards: a) Jobsite: On December 21, 2016 and at times prior thereto an employee used a self-supporting ladder that was not tall enough to safely position the employee for the work being done. The employee did not recognize or acknowledge the hazard of working from the top cap of a self-supporting ladder. Actions were not taken to minimize or correct the hazard. Note) Certification of corrective action is required for this item. |
|
|