Search icon

HB SIDING, INC.

Company Details

Name: HB SIDING, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Active-Good Standing
Date of registration: 15 Sep 2000 (25 years ago)
Financial Date End: 30 Sep 2025
Entity Number: 414423
Place of Formation: IDAHO
File Number: 414423
ZIP code: 83642
County: Ada County
Mailing Address: JOE BUREAU STE 107 269 E 5TH ST MERIDIAN, ID 83642-1450

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
HB SIDING, INC. 401K PLAN 2023 820526613 2024-07-02 HB SIDING, INC. 24
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2022-01-01
Business code 238170
Sponsor’s telephone number 2083763521
Plan sponsor’s address 269 E. 5TH ST. STE. 107, MERIDIAN, ID, 83642

Signature of

Role Plan administrator
Date 2024-07-02
Name of individual signing SIENNA PETERSON
Valid signature Filed with authorized/valid electronic signature
HB SIDING, INC. 401K PLAN 2022 820526613 2023-06-05 HB SIDING, INC. 21
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2022-01-01
Business code 238170
Sponsor’s telephone number 2088674200
Plan sponsor’s address 269 E. 5TH ST. STE. 107, MERIDIAN, ID, 83642

Signature of

Role Plan administrator
Date 2023-06-05
Name of individual signing BOBBI GATELY
Valid signature Filed with authorized/valid electronic signature

Agent

Name Role Address
JOE BUREAU Agent 269 E 5TH STE 107, MERIDIAN, ID 83642

President

Name Role Address Appointed On
JOE BUREAU President 269 E 5TH STE 107, MERIDIAN, ID 83642 2020-08-03

Vice President

Name Role Address Appointed On Resigned On
Jim Herwy Vice President 269 E 5TH STE 107, MERIDIAN, ID 83642 2023-08-03 2023-08-03

Filing

Filing Name Filing Number Filing date
Annual Report 0005931440 2024-10-07
Annual Report 0005343838 2023-08-03
Annual Report 0004946058 2022-10-07
Annual Report 0004392349 2021-08-25
Annual Report 0003952990 2020-08-03
Annual Report 0003613278 2019-09-03
Annual Report 0002771111 2018-07-31
Annual Report 0002771108 2017-07-24
Annual Report 0002771107 2016-07-25
Annual Report 0002771105 2015-07-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346268873 1032500 2022-10-06 680 S CALHOUN RD, STAR, ID, 83669
Inspection Type Prog Other
Scope Partial
Safety/Health Safety
Close Conference 2022-10-06
Emphasis L: FORKLIFT, P: FORKLIFT
Case Closed 2023-03-08

Related Activity

Type Inspection
Activity Nr 1626891
Safety Yes
Type Inspection
Activity Nr 1626883
Safety Yes
345726491 1032500 2022-01-13 6072 N HAMPSTEAD, BOISE, ID, 83714
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-01-13
Emphasis L: FALL
Case Closed 2022-06-28

Related Activity

Type Complaint
Activity Nr 1854055
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-06-09
Abatement Due Date 2022-07-07
Current Penalty 2196.0
Initial Penalty 4931.0
Final Order 2022-06-22
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On January 13, 2022, an employee was exposed to fall hazards while performing siding activities approximately 10 feet above concrete without fall protection. Note: Abatement certification is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-06-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-06-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On January 13, 2022, an employees were accessing a roof from a ladder that was extended approximately 1 foot above the roof surface. Note: Abatement certification is NOT required for this item.
339569220 1032500 2014-01-24 LOT 3, BLOCK 39, 2573 HONEYCOMB, BOISE, ID, 83716
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-01-24
Emphasis L: FALL, L: RESCON
Case Closed 2015-03-26

Related Activity

Type Complaint
Activity Nr 869630
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 B
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 2100.0
Initial Penalty 2100.0
Final Order 2014-04-24
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(b): Helmets for the protection of employees against impact and penetration of falling and flying objects did not meet the specifications contained in American National Standards Institute Z89.1-1969, section 5.1, Safety Requirements for Industrial Head Protection: (a) On or about January 24, 2014 and at times prior thereto an employee was utilizing a damaged hard hat for purposes of head protection. (b) On or about January 24, 2014 and at times prior thereto an employee was utilizing a hard hat that had approximately 9 holes drilled in to the shell of the hat. Note: Abatement certification IS required for this item
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260403 B01
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 1600.0
Initial Penalty 2800.0
Final Order 2014-04-24
Nr Instances 2
Nr Exposed 10
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: (a) On or about January 24, 2014 and at times prior thereto, damaged 120v electrical extension cords were being utilized for powering saws, radios and other equipement. Note: Abatement certification IS required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-24
Nr Instances 1
Nr Exposed 10
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. (a) On or about January 24, 2014 and at times prior thereto, employees were utilizing uncovered wall outlets for powering equipement such as, but not limited to, air compressors, extension cords and saws. Note: Abatement certification IS required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-24
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) On or about January 24, 2014 and at times prior thereto, a 120v electrical extension cord which was damaged down to the copper wire was being used to power equipment such as, but not limited to radios and circular saws. Note: Abatement certification IS required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260502 D15
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 1600.0
Initial Penalty 2800.0
Final Order 2014-04-24
Nr Instances 3
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. (a) Front (east facing) roof: On or about January 24, 2014 and at times prior thereto, a roof anchor mounted to the peak and being utilized by two workers, doing siding activities between 10 and 15 feet from the ground, was not designed to accomodate more than one worker in the event of a fall. (b) Side (north facing) roof: On or about January 24, 2014 and at times prior thereto, a roof anchor mounted to the side of the facia was being utilized by two workers doing siding activities between 10 and 15 feet from the ground and was not designed to accomodate more than one worker in the event of a fall. (c) Side (north facing) roof: On or about January 24, 2014 and at times prior thereto, a roof anchor mounted to the side of the facia was not designed to withstand a force of 5000 pounds when mounted at this angle. Note: Abatement certification IS required for this item.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19261053 B04
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 3500.0
Initial Penalty 5600.0
Final Order 2014-04-24
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) Front roof: On or about January 24, 2014 and at times prior thereto, an employee performing siding activities, approximately 10 to 15 feet above the ground, was utilizing an approximately 6 foot Werner A-frame ladder on the roof in the closed position. HB Siding, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 98245, citation number 1, item number 2a and was affirmed as a final order on October 26, 2011, with respect to a workplace located at 11962 Barclay Bay, Star, ID 83669. Note: Abatement certification AND documentation IS required.
Citation ID 03001
Citaton Type Repeat
Standard Cited 19260102 A02
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 140.0
Initial Penalty 140.0
Final Order 2014-04-24
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(2): Eye and face protection required by this Part did not meet the requirements specified in American National Standards Institute, Z87.1-1968, Practice for Occupational and Educational Eye and Face Protection: (a) On or about January 24, 2014 and at times prior thereto, an employee using a circular Skilsaw was wearing SCOTT ski goggles in lieu of ANSI rated safety glasses or goggles. (b) On or about January 24, 2014 and at times prior thereto, an employee operating an pneumatic nail gun was wearing sunglasses that had not been ANSI rated. HB Siding, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 582318, citation number 2, item number 1 and was affirmed as a final order on November 16, 2012, with respect to a workplace located at Lot 92 Rolling Hills, Boise, ID 83714. Note: Abatement certification AND documentation IS required.
Citation ID 04001A
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2014-09-22
Abatement Due Date 2014-11-07
Current Penalty 700.0
Initial Penalty 700.0
Final Order 2014-10-20
Nr Instances 3
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) The Employer did not provide abatement certification for Citation Items 1, 2, and 3 for hazards required to be abated by April 14, 2014. Abatement Certification is required for this item.
Citation ID 04001B
Citaton Type Other
Standard Cited 19030019 D01
Issuance Date 2014-09-22
Abatement Due Date 2014-11-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-10-20
Nr Instances 2
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. a) The Employer did not provide supporting documentation as required for Repeat citation items 2 and 3 related to ladder usage and eye protection. These were required to be abated by April 14, 2014. Abatement certification is required for this item.
336569785 1032500 2012-09-17 565 NORTH BAXTER, EAGLE, ID, 83616
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2012-09-17
Emphasis L: FALL, L: RESCON
Case Closed 2012-12-31

Related Activity

Type Referral
Activity Nr 582250
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2012-10-24
Current Penalty 1428.0
Initial Penalty 2380.0
Final Order 2012-11-19
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On the roof, front side of structure: On September 17, 2012 and at times prior thereto an employee performed siding activities without a fall protection system in place. b) On the roof, back side of structure: On September 17, 2012 employees performing siding activities wore personal fall arrest systems that were not attached to the lanyards that were in place. Note) Abatement certification is NOT required for this item.
335823183 1032500 2012-08-16 LOT 92 ROLLING HILLS AT HIDDEN SPRINGS, BOISE, ID, 83714
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2012-08-16
Emphasis L: FALL, L: RESCON
Case Closed 2013-04-07

Related Activity

Type Referral
Activity Nr 511672
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2012-10-30
Abatement Due Date 2012-10-31
Current Penalty 1260.0
Initial Penalty 2100.0
Final Order 2012-11-19
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Back side of roof: On or about August 16, 2012 two employees engaged in siding activities were approximately 9.9 feet above ground without any apparent fall protection. Note: Abatement certification required.
Citation ID 02001
Citaton Type Other
Standard Cited 19260102 A02
Issuance Date 2012-10-30
Abatement Due Date 2012-11-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-19
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(2): Eye and face protection required by this Part did not meet the requirements specified in American National Standards Institute, Z87.1-1968, Practice for Occupational and Educational Eye and Face Protection: a) Back side of roof: On or about August 16, 2012 two employees engaged in siding activities were utilizing HITACHI NV 65AH nail guns without appropriate eye protection. Note: Abatement certification required.
Citation ID 02002
Citaton Type Other
Standard Cited 19260300 A
Issuance Date 2012-10-30
Abatement Due Date 2012-11-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-19
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(a): Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition: a) Back side of house: On or about August 16, 2012 a Bosch chop saw being utilized to make precision cuts to the siding being installed had a plug that was pulled away from the cord exposing sheathed wires. Note: Abatement certification required.
330982455 1032500 2011-08-31 11962 BARCLAY BAY, STAR, ID, 83669
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2011-08-31
Emphasis L: FALL, L: RESCON
Case Closed 2012-02-07

Related Activity

Type Referral
Activity Nr 78216
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2011-10-04
Abatement Due Date 2011-10-05
Current Penalty 1000.0
Initial Penalty 1785.0
Final Order 2011-10-26
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Jobsite: On August 31, 2011 and times prior thereto, employees perfoming siding activities used powered tools, to include nail guns, without any eye protection. Note) Abatement certification IS required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2011-10-04
Abatement Due Date 2011-10-05
Current Penalty 1300.0
Initial Penalty 1785.0
Final Order 2011-10-26
Nr Instances 3
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Jobsite: On August 31, 2011 and times prior thereto, employees performing siding activities used an approximate six foot self supporting "A" frame ladder in the closed position. Note) Abatement certification IS required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2011-10-04
Abatement Due Date 2011-10-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-10-26
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) Jobsite: On August 31, 2011 an employee performing siding activities worked from an approximate 15 foot extension ladder that was positioned such that the foot of the ladder was approximately nine and a half feet out from the top support of the ladder. Note) Abatement certification IS required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2011-10-04
Abatement Due Date 2011-10-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-10-26
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Jobsite: On September 2, 2011 and times prior therto, employees performing siding activites worked from the top cap and top step of a six foot self supporting A-frame ladders. Note) Abatement certification IS required for this item.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19261060 A01 III
Issuance Date 2011-10-04
Abatement Due Date 2011-10-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-10-26
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee had been trained by a competent person in the proper construction, use, placement, and care in handling of all stairways and ladders: a) Jobsite: On August 31, 2011 and times prior thereto employees and the responsible person on the jobsite did not recognize the hazard of using an A-frame ladder in a position it was not designed to be used in, and take actions to minimize or correct the hazard. b) Jobsite: On August 31, 2011 and times prior thereto employees and the responsible person on the jobsite did not recognize the hazard of working from an extension ladder which was not positioned at the appropriate four to one angle, and take actions to minimize or correct the hazard. c) Jobsite: On September 2, 2011 and times prior thereto employees and the responsible person on the jobsite did not recognize the hazard of working from the top cap or top step of an A-frame ladder, and take actions to minimize or correct the hazard. Note) Abatement certifiaction IS required for this item. the closed position
Citation ID 02001
Citaton Type Other
Standard Cited 19040029 A
Issuance Date 2011-10-04
Abatement Due Date 2011-10-05
Current Penalty 250.0
Initial Penalty 700.0
Final Order 2011-10-26
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.29(a): A Log of all Work-Related Injuries and Illnesses (OSHA Form 300), and/or the Summary of Work-Related Injuries and Illnesses, (OSHA Form 300-A), and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment: a) Calendar year 2009: An OSHA 300 log of injuries and illnesses, and an OSHA 300A, annual summary of injuries and illnesses was not maintained by the employer when a work-related injury occurred in August 2009 which involved a partially amputated finger, resulting in restricted work activity and lost work days. b) Calendar year 2010: An OSHA 300 log of injuries and illnesses, and an OSHA 300A, annual summary of injuries and illnesses was not maintained by the employer when a work-related injury occurred in July 2010 which involved a partially amputated thumb, resulting in restricted work activity and lost work days. Note) Abatement certification IS required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4179577107 2020-04-13 1087 PPP 269 E 5TH Street, MERIDIAN, ID, 83642-1415
Loan Status Date 2021-08-19
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 250000
Loan Approval Amount (current) 250000
Undisbursed Amount 0
Franchise Name -
Lender Location ID 56102
Servicing Lender Name KeyBank National Association
Servicing Lender Address 127 Public Sq, CLEVELAND, OH, 44114-1217
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address MERIDIAN, ADA, ID, 83642-1415
Project Congressional District ID-01
Number of Employees 35
NAICS code 238160
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 56102
Originating Lender Name KeyBank National Association
Originating Lender Address CLEVELAND, OH
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 253020.55
Forgiveness Paid Date 2021-07-13

Date of last update: 07 Apr 2025

Sources: Idaho Secretary of State