Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-01-18
|
Emphasis |
L: FORKLIFT, P: FORKLIFT
|
Case Closed |
2019-04-08
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
2587.0 |
Initial Penalty |
5174.0 |
Final Order |
2018-03-29 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) On or about January 18, 2018 and at times prior thereto, employees were working greater than 9 feet, while assembling truck camper roofs, where no fall protection was used. b) On or about January 18, 2018 and at times prior thereto, employees were working greater than 13 feet, while assembling tiny home roofs, where no fall protection was used. Note-Abatement documentation and certification are required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100030 A01 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-29 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.30(a)(1): Before any employee is exposed to a fall hazard, the employer did not provide training for each employee who uses personal fall protection systems or who was required to be trained as specified elsewhere in this subpart. a) On or about January 18, 2018 and at times prior thereto, employees were exposed to fall hazards greater than 9 and 13 feet to the ground below, where untrained employees were unable to recognize or avoid the hazards, or to wear and use personal fall arrest systems. Note-Abatement documentation and certification are required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100178 A06 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
2587.0 |
Initial Penalty |
5174.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place: a) On or about January 18, 2018 and at times prior thereto, a propane powered Hyster forklift was in use where, among other missing items, name plates and identification markings were missing, which would provide operator aides, warnings and cautions, and maximum lifting capacities. Note-Abatement documentation and certification are required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) On or about January 18, 2018 and at times prior thereto, employees were operating a forklift, where the employer did complete forklift training for employees, or ensure forklift training had been accomplished. Note-Abatement documentation and certification are required for this item. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100213 C03 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
942.5 |
Initial Penalty |
1885.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) On or about January 18, 2018 and at times prior thereto, employees were ripping plywood and formica on a table saw where no anti-kickback fingers were installed to prevent materials from flying back and hitting the saw operator. Note-Abatement certification is required for this item. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
942.5 |
Initial Penalty |
1885.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about January 18, 2018 and at times prior thereto, employees were cleaning sawdust and building material debris with air in excess of 100 psi. Note-Abatement certification is required for this item. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2018-03-22 |
Abatement Due Date |
2018-04-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about January 18, 2018 and at times prior thereto, a black flexible 220V cable was hard wired directly to a junction box and provided power to a table saw. Note-Abatement certification is required for this item. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100334 A01 |
Issuance Date |
2018-03-22 |
Abatement Due Date |
2018-04-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
13 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation: a) On or about January 18, 2018 and at times prior thereto, a 110V yellow extension cord, which provided power to a Dewalt compound miter saw, was wrapped around steel beams overhead, and hung from the top of a vertical 2X4 with wire. Note-Abatement certification is required for this item. |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-01-18
|
Case Closed |
2018-12-10
|
Related Activity
Type |
Complaint |
Activity Nr |
1299160 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
1108.5 |
Initial Penalty |
2217.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On the production floor: On January 18, 2018 the employer had not established a written respiratory protection program for employees required to use 3M 6000-series tight-fitting respirators while engaged in work activities. Note: Abatement certification is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On the production floor: On and before January 18, 2018 employees required to use tight fitting respirators did not receive medical evaluations prior to using a respirator. Note: Abatement certification is required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On the production floor: On and before January 18, 2018 employees required to use tight fitting respirators did not receive respirator fit tests prior to using a respirator. Note: Abatement certification is required for this item. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Production floor: On and before January 18, 2018 employees required to use or potentially exposed to hazardous chemicals such as lacquer, adhesives and paints did not receive hazard communication training. Note: Abatement certification is required for this item. |
|
|