Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-01-27
|
Emphasis |
L: FALL
|
Case Closed |
2015-09-30
|
Related Activity
Type |
Complaint |
Activity Nr |
869743 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2014-01-29 |
Abatement Due Date |
2014-02-04 |
Current Penalty |
1360.0 |
Initial Penalty |
1360.0 |
Final Order |
2014-02-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest system was not rigged so that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) On or before January 27, 2014, and at times prior thereto, an employee was exposed to the danger of falling to the ground because his rope grab was not adjusted to prevent falling more than six (6) feet. Note: Abatement certification is NOT required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 II |
Issuance Date |
2014-01-29 |
Abatement Due Date |
2014-02-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) On or before January 27, 2014, and at times prior thereto, employees applying composition shingles to a residence were not adequately trained in proper use of fall protection equipment as evidenced by the loop of rope hanging over the edge of the eve. Note: Abatement certification IS required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2014-01-29 |
Abatement Due Date |
2014-02-04 |
Current Penalty |
1020.0 |
Initial Penalty |
1020.0 |
Final Order |
2014-02-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or before January 27, 2014, and at times prior thereto, employees applying composition shingles with a pneumatic roof nail gun were exposed to the danger of being struck in the eye because they were not wearing any eye protection. Note: Abatement certification IS required for this item. |
|
|