340699768
|
1032500
|
2015-05-13
|
FILMORE AND CANYON SPRINGS ROADS, TWIN FALLS, ID, 83301
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-05-13
|
Emphasis |
N: TRENCH
|
Case Closed |
2015-10-02
|
Related Activity
Type |
Referral |
Activity Nr |
991595 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260651 C02 |
Issuance Date |
2015-06-29 |
Abatement Due Date |
2015-07-17 |
Current Penalty |
0.0 |
Initial Penalty |
200.0 |
Final Order |
2015-07-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) On May 13, 2015, An employee was working in an excavation that was approximately 51 inches to 54 inches (4.25 feet to 4.5 feet) in depth without a ladder. The Eureka Construction & Excavating, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 315026773, citation number 1, item number 1 and was affirmed as a final order on 3/17/2011, with respect to a workplace located at Frontage and Farmore Roads, Jerome, Idaho. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
2015-06-29 |
Abatement Due Date |
2015-07-17 |
Current Penalty |
3500.0 |
Initial Penalty |
5600.0 |
Final Order |
2015-07-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) On May 13, 2015, the spoil pile for an excavation measuring approximately 51 to 54 inches deep by 56 inches wide by 98 inches in length, was positioned on the edge of the excavation wall. This exposed the employee working in the excavation to the hazard of being struck by falling rock and dirt and increased the potential of a cave in. Eureka Construction & Excavating, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 107075, citation number 1, item number 1 and was affirmed as a final order on 12/5/2011, with respect to a workplace located at 100 Sunpeak Drive, Sun Valley, Idaho. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260100 A |
Issuance Date |
2015-06-29 |
Abatement Due Date |
2015-07-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) On May 13, 2015, an employee working in a bent over position in an excavation was exposed to the hazard of being struck in the head by falling rock and debris from the spoil pile. |
|
|
331073155
|
1032500
|
2011-09-21
|
140 N. HULAN WAY, KETCHUM, ID, 83340
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-09-21
|
Emphasis |
L: RESCON, N: TRENCH
|
Case Closed |
2012-01-31
|
Related Activity
Type |
Referral |
Activity Nr |
81665 |
Safety |
Yes |
|
|
331070755
|
1032500
|
2011-09-20
|
100 SUNPEAK DRIVE, SUN VALLEY, ID, 83353
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-09-26
|
Emphasis |
L: RESCON, N: TRENCH
|
Case Closed |
2011-12-05
|
Related Activity
Type |
Referral |
Activity Nr |
81423 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
107072 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
107074 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
107115 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260651 J02 |
Issuance Date |
2011-11-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-12-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) East side of site; On or about 9/20/11 and at times prior thereto, all of the excavated material was not placed at least 2 feet away from the edge of an excavation prior to allowing employee to enter and install electrical conduit. Note: Abatement certification is NOT required for this item. |
|
|
315026773
|
1032500
|
2011-01-31
|
FRONTAGE AND FARMORE ROADS, JEROME, ID, 83338
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-01-31
|
Emphasis |
N: TRENCH, S: COMMERCIAL CONSTR, S: POWERED IND VEHICLE, S: STRUCK-BY, S: TRENCHING
|
Case Closed |
2011-03-25
|
Related Activity
Type |
Referral |
Activity Nr |
200251239 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
2011-03-02 |
Abatement Due Date |
2011-03-10 |
Current Penalty |
1500.0 |
Initial Penalty |
3000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
05 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2011-03-02 |
Abatement Due Date |
2011-03-10 |
Current Penalty |
2100.0 |
Initial Penalty |
4200.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
10002B |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2011-03-02 |
Abatement Due Date |
2011-03-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
|
311582514
|
1032500
|
2009-06-04
|
EAST FORK & AUDUBON ROADS, HAILEY, ID, 83333
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2009-06-04
|
Emphasis |
N: TRENCH, S: POWERED IND VEHICLE, S: TRENCHING, S: STRUCK-BY, S: HWY STREET BRIDGE CONSTR
|
Case Closed |
2011-03-14
|
Related Activity
Type |
Referral |
Activity Nr |
200248334 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260303 B01 |
Issuance Date |
2009-06-24 |
Abatement Due Date |
2009-06-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
|