345843148
|
1032500
|
2022-03-17
|
600 E RIVERSIDE DRIVE, EAGLE, ID, 83616
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-03-17
|
Emphasis |
L: FALL
|
Case Closed |
2023-10-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1584309 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1584312 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2022-03-24 |
Abatement Due Date |
2022-04-05 |
Current Penalty |
4144.0 |
Initial Penalty |
4144.0 |
Final Order |
2022-10-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) 600 E Riverside Drive, Eagle, ID 83616: On or about March 17, 2022, employees were exposed to falls of approximately 26-48 feet while performing roofing activities without fall protection. Note - Abatement certification is required for this item. |
|
|
345005920
|
1032500
|
2020-11-02
|
4107 EAST OVERLAND ROAD, MERIDIAN, ID, 83642
|
|
Inspection Type |
Prog Other
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-11-02
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2023-10-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1500442 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2020-11-10 |
Current Penalty |
1966.0 |
Initial Penalty |
1966.0 |
Final Order |
2021-01-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: a) Silverstone Apartments jobsite: On November 2, 2020 and at times prior thereto employees were not wearing safety glasses while performing siding activities using a pneumatic nail gun. Note) Corrected during inspection. |
|
|
343577631
|
1032500
|
2018-11-01
|
6267 S MAPLE GROVE RD, BOISE, ID, 83709
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-01
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2022-07-19
|
Related Activity
Type |
Complaint |
Activity Nr |
1357756 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1357756 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2019-04-19 |
Abatement Due Date |
2019-06-06 |
Current Penalty |
3789.0 |
Initial Penalty |
3789.0 |
Final Order |
2019-06-27 |
Nr Instances |
4 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: a) Jobsite: On November 1, 2018 and at times prior thereto; employer did not ensure that its siding employees were protected from electrical hazards; electrical cords attached to a radial saw, Skilsaw, and powerbox were found frayed and/or inadequately repaired. b) Outdoors: On November 1, 2018 and at times prior thereto; equipment operators used a DeWalt radial saw and Skilsaw to cut and rip Silica containing HardiePlank siding, but engineering controls were not in place, and a dust cloud was visible around the employee. Note* Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261153 C01 |
Issuance Date |
2019-04-19 |
Abatement Due Date |
2019-08-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-06-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, and did not assess and limit the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section. a) Outdoors: On or about November 1, 2018 and at times prior thereto; controlling employer did not ensure subcontractor's employees using a hand-held Skilsaw and Dewalt radial saw were using a dust collection control method to reduce silica containing cement fiber board - HardiePlank airborne particulate exposures. Note* Abatement certification IS required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19261153 F01 |
Issuance Date |
2019-04-19 |
Abatement Due Date |
2019-06-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-06-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(f)(1): The employer allowed dry sweeping or dry brushing where such activity could contribute to employee exposure to respirable crystalline silica and wet sweeping, HEPA-filtered vacuuming or other methods were feasible: a) Outdoors: On or about November 1, 2018 and at times prior thereto; employees used a broom to sweep Silica containing HardiePlank dust; a thick collection of dust on the ground was visible below saw cutting surfaces, and the surrounding work areas which are not cleared on a daily basis. Note* Abatement certification IS required for this item. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19261153 G01 |
Issuance Date |
2019-04-19 |
Abatement Due Date |
2019-08-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-06-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan: a) Outdoors: On or about November 1, 2018 and at times prior thereto; Saw operators were cutting and ripping HardiePlank Silica containing siding with the use of a hand-held Skilsaw and Dewalt radial saw. Note* Abatement certification IS required for this item. |
|
Citation ID |
01001E |
Citaton Type |
Serious |
Standard Cited |
19100134 K06 |
Issuance Date |
2019-04-19 |
Abatement Due Date |
2019-08-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-06-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (Construction Reference 1926.103): a) Outdoors: On or about November 5, 2018 and at times prior thereto; Saw operators were cutting and ripping HardiePlank Silica containing siding with the use of a hand-held Skilsaw and Dewalt radial saw while wearing an N95 dust mask with a beard. Note* Abatement certification IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260403 A |
Issuance Date |
2019-04-19 |
Current Penalty |
3031.0 |
Initial Penalty |
3031.0 |
Final Order |
2019-06-27 |
Nr Instances |
3 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(a): All electrical conductors and equipment were not approved: a) Outdoors - Dewalt Chop Saw: On November 1, 2018 and at times prior thereto; damaged cords were not repaired to the state in which they were initially approved; strain relief. b) Outdoors - Skilsaw hand-held radial saw: On November 1, 2018 and at times prior thereto; frayed cord. Note* Abatement certification IS required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 II I |
Issuance Date |
2019-04-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-06-27 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: a) Outdoors - Common Area in front of Buildings A and B: On November 1, 2018 and at times prior thereto; flexible cords attached to daily use equipment to included a Dewalt radial saw and hand-held Skilsaw were found frayed, repaired and strain relief did not fit securely. Note* Abatement certification IS required for this item. |
|
|
339854721
|
1032500
|
2014-07-17
|
1585 SOUTH ALANTE, BOISE, ID, 83709
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-07-17
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2016-01-07
|
Related Activity
Type |
Inspection |
Activity Nr |
985477 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
985476 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
898792 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
985473 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-06 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-08-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a) Building 1585: On July 17, 2014 employees engaged in siding activities on a second floor balcony without a fall protection system in place. Note) Abatement certification IS required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-06 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-08-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Building 1585: On July 17, 2014 an employee stood on the top cap of an eight foot ladder to perform siding activities. Note) Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260452 J02 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) Building 1585: On July 17, 2014 the pump jack scaffold in use was not secured at the bottom. Note) Abatement certification IS required for this item. |
|
|