Search icon

Northwest Framing LLC

Company Details

Name: Northwest Framing LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 26 Aug 2020 (5 years ago)
Financial Date End: 31 Aug 2023
Date dissolved: 09 Nov 2023
Entity Number: 3979623
Place of Formation: IDAHO
File Number: 723201
ZIP code: 83646
County: Ada County
Principal Address: 3710 N CENTREPOINT WAY # E101 MERIDIAN, ID 83646-3711
Mailing Address: 71 SW 3RD ST ONTARIO, OR 97914-2742

Agent

Name Role Address
Jokcsan F Santoyo Agent 3710 N CENTREPOINT WAY # 101, MERIDIAN, ID 83646-3711

Member

Name Role Address Appointed On
Jocksan F Santoyo Member 3710 N CENTREPOINT WAY # E101, MERIDIAN, ID 83646-3711 2020-09-21

Manager

Name Role Address Appointed On
Jockson Santoyo Manager 71 SW 3RD ST, ONTARIO, OR 97914-2742 2023-02-21

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0005473852 2023-11-09
Application for Reinstatement 0005121115 2023-02-21
Dissolution/Revocation - Administrative 0004979173 2022-11-05
Annual Report 0004334723 2021-07-06
Amendment to Certificate 0004008318 2020-09-21
Initial Filing 0003979623 2020-08-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345317754 1032500 2021-05-18 16852 IDAHO CENTER BLVD, NAMPA, ID, 83651
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-05-18
Emphasis N: CTARGET, P: CTARGET
Case Closed 2022-01-26

Related Activity

Type Inspection
Activity Nr 1531770
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2021-08-11
Abatement Due Date 2021-09-07
Current Penalty 1755.0
Initial Penalty 1755.0
Final Order 2021-10-21
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: 2) Lot 5/6. On or about May 18, 2021 and at times prior thereto; employees were exposed to fall hazards of nine feet when framing the second floor of residential townhomes. NOTE- Abatement certification is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A02
Issuance Date 2021-08-11
Abatement Due Date 2021-09-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-10-21
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii) 2) On or about May 18, 2021 and at times prior thereto; employees were framing the second floor of residential townhomes nine feet high, and were not trained to recognize fall hazards, or utilize fall protection. NOTE- Abatement certification is required for this item.