Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-08-04
|
Emphasis |
L: FALL, N: CTARGET
|
Case Closed |
2012-06-18
|
Related Activity
Type |
Inspection |
Activity Nr |
97806 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
97788 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19260501 B04 II |
Issuance Date |
2011-10-27 |
Current Penalty |
1390.0 |
Initial Penalty |
2781.0 |
Contest Date |
2011-11-29 |
Final Order |
2012-03-05 |
Nr Instances |
9 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: (a) Schweitzer Project roof: On 8/4/11 and at times prior thereto, roofing workers were exposed to roof holes that were not barricaded or covered. Note: Abatement certification IS NOT required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 III |
Issuance Date |
2011-10-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2011-11-29 |
Final Order |
2012-03-15 |
Nr Instances |
9 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(iii): Each employee on a walking/working surface was not protected from objects falling through holes (including skylights) by covers: (a) Building interior: On 08/04/11 and at times prior thereto, roofers tools, equipment, and personal items stored at the immediate edge of roof openings exposed subcontractor employees to falling object hazards. Note: Abatement certification IS NOT required for this item. |
|
|