Name: | LOTUS VAPING TECHNOLOGIES, LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 13 Jun 2013 (12 years ago) |
Financial Date End: | 30 Jun 2025 |
Entity Number: | 386632 |
Place of Formation: | IDAHO |
File Number: | 386632 |
ZIP code: | 83714 |
County: | Ada County |
Principal Address: | 5118 N SAWYER AVE BOISE, ID 83714 |
Mailing Address: | 5118 N SAWYER AVE BOISE, ID 83714-1489 |
Type | Company Name | Company Number | State |
---|---|---|---|
Headquarter of | LOTUS VAPING TECHNOLOGIES, LLC, MISSISSIPPI | 1268072 | MISSISSIPPI |
Headquarter of | LOTUS VAPING TECHNOLOGIES, LLC, ALASKA | 10157586 | ALASKA |
Headquarter of | LOTUS VAPING TECHNOLOGIES, LLC, KENTUCKY | 1116617 | KENTUCKY |
Name | Role | Address |
---|---|---|
ENTITY SERVICES, INC. | Agent | 967 E PARKCENTER BLVD # 311, BOISE, ID 83706 |
Name | Role | Address | Appointed On |
---|---|---|---|
Michael R Rodgers | Manager | PO BOX 891, MERIDIAN, ID 83680 | 2020-07-02 |
Name | Role | Address | Appointed On |
---|---|---|---|
Michael Larsen | Member | 4000 N MCDERMOTT RD, MERIDIAN, ID 83646 | 2024-05-06 |
Robert Henry | Member | 411 N BENEWAH ST, NAMPA, ID 83651 | 2024-05-06 |
Matthew Treece | Member | 3041 W DITCH CREEK ST, MERIDIAN, ID 83646 | 2024-05-06 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005725727 | 2024-05-06 |
Annual Report | 0005218373 | 2023-05-03 |
Annual Report | 0004732868 | 2022-05-04 |
Annual Report | 0004305451 | 2021-06-04 |
Annual Report | 0003924897 | 2020-07-02 |
Amendment to Certificate | 0003856356 | 2020-05-01 |
Change of Registered Office/Agent/Both (by Entity) | 0003856341 | 2020-05-01 |
Annual Report | 0003548770 | 2019-06-21 |
Annual Report | 0002658412 | 2018-04-25 |
Annual Report | 0002658410 | 2017-05-18 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345819155 | 1032500 | 2022-03-04 | 5118 NORTH SAWYER AVENUE, BOISE, ID, 83714 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1870946 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100134 C01 |
Issuance Date | 2022-09-01 |
Current Penalty | 3082.0 |
Initial Penalty | 6164.0 |
Final Order | 2022-09-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Clean Room: On March 4, 2022 the employer had not established a written respiratory protection program for employees required to wear full-faced and half-faced elastomeric respirators while working with and around raw, liquid nicotine. Note: Abatement certification is not required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100134 E01 |
Issuance Date | 2022-09-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2022-09-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Clean Room: On March 4, 2022 the employer had not provided medical evaluations for employees required to wear full-faced and half-faced elastomeric respirators while working with and around raw, liquid nicotine. Note: Abatement certification is not required for this item. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19100134 F01 |
Issuance Date | 2022-09-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2022-09-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Clean Room: On March 4, 2022 the employer had not provided fit testing evaluations for employees required to wear full-faced and half-faced elastomeric respirators while working with and around raw, liquid nicotine. Note: Abatement certification is not required for this item. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100305 G01 IV A |
Issuance Date | 2022-09-01 |
Abatement Due Date | 2022-09-28 |
Current Penalty | 2465.5 |
Initial Penalty | 4931.0 |
Final Order | 2022-09-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Clean Room: On June 23, 2022 and at times prior, an extension cord was used in conjunction with a power strip as permanent wiring for an electric pump located within the clean room. Note: Abatement certification IS required for this item. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100305 G01 IV B |
Issuance Date | 2022-09-01 |
Abatement Due Date | 2022-09-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2022-09-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(1)(iv)(B):Flexible cords and/or cables were run through holes in walls, ceilings, or floors: (a) Clean Room: On June 23, 2022 and at times prior, an extension cord being used to power a motorized pump was strung from the lab above the ceiling and down the back wall of the clean room. Note: Abatement certification IS required for this item. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19100305 G01 IV C |
Issuance Date | 2022-09-01 |
Abatement Due Date | 2022-09-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2022-09-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(1)(iv)(C):Flexible cords and cables were used where run through doorways, windows, or similar openings. (a) Clean Room: On June 23, 2022 and at times prior, an extension cord being used to power a motorized pump was strung from the lab through the doorway and down the back wall of the clean room. Note: Abatement certification IS required for this item. |