Search icon

EXCELLENCE HEATING & COOLING LLC

Company Details

Name: EXCELLENCE HEATING & COOLING LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 29 Apr 2013 (12 years ago)
Financial Date End: 30 Apr 2022
Date dissolved: 09 Jul 2022
Entity Number: 382449
Place of Formation: IDAHO
File Number: 382449
ZIP code: 83402
County: Bonneville County
Principal Address: 480 N UTAH AVE IDAHO FALLS, ID 83402
Mailing Address: 480 N UTAH AVE IDAHO FALLS, ID 83402-3311

Agent

Name Role Address
BRIAN MEDRAIN Agent 480 N. UTAH AVE, IDAHO FALLS, ID 83402

Manager

Name Role Address Appointed On
BRIAN MEDRAIN Manager 3550 CRESTWOOD LN., IDAHO FALLS, ID 83404 2021-03-05

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0004810974 2022-07-09
Annual Report 0004198514 2021-03-05
Annual Report 0003807594 2020-03-09
Annual Report 0003519407 2019-05-21
Annual Report 0002640473 2018-05-22
Annual Report 0002640471 2017-03-06
Annual Report 0002640469 2016-02-24
Annual Report 0002640467 2015-02-22
Annual Report 0002640465 2014-04-08
Initial Filing 0000382449 2013-04-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341851335 1032500 2016-10-17 2844 E 14TH N, IDAHO FALLS, ID, 83401
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-10-18
Emphasis L: FALL, L: FORKLIFT
Case Closed 2017-07-07

Related Activity

Type Referral
Activity Nr 1146220
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 A06
Issuance Date 2016-10-27
Abatement Due Date 2016-11-23
Current Penalty 1871.0
Initial Penalty 3741.0
Final Order 2017-02-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person and were not constructed and loaded in accordance with that design. a) On or about October 11, 2016 or prior thereto: Employees were installing a metal hood for a HVAC fan at a height of approximately 25 feet from ground level. Employees were standing on two pallets screwed together as a platform, that was elevated by a Caterpillar Tele-Handler. Employees were not wearing fall protection during this activity. The platform was not designed by a qualified person, and had been assembled on site. NOTE: Abatement certification and documentation are required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-10-27
Abatement Due Date 2016-11-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-02-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as follows: a) On or about October 11, 2016 or prior thereto: Employees were installing a metal hood for a HVAC fan at a height of approximately 25 feet from ground level. Employees were standing on two pallets screwed together as a platform, that was elevated by a Caterpillar Tele-Handler. Employees were not wearing fall protection during this activity. The platform represented a slip, trip and fall hazard as it was not fully planked. There were not uprights or guardrails for this platform. NOTE: Abatement certification and documentation are required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 C02 V
Issuance Date 2016-10-27
Abatement Due Date 2016-11-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-02-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms unless the entire platform was not attached to the fork. a) On or about October 11, 2016 or prior thereto: Employees were installing a metal hood for a HVAC fan at a height of approximately 25 feet from ground level. Employees were standing on two pallets screwed together as a platform, that was elevated by a Caterpillar Tele-Handler. The scaffold platform was not secured to the Tele-Handler. NOTE: Abatement certification and documentation are required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2016-10-27
Abatement Due Date 2016-11-23
Current Penalty 1870.0
Initial Penalty 3741.0
Final Order 2017-02-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. a) On or about October 11, 2016 or prior thereto: Employees were installing a metal hood for a HVAC fan at a height of approximately 25 feet from ground level. Employees were standing on two pallets screwed together as a platform, that was elevated by a Caterpillar Tele-Handler. Employees were not wearing fall protection during this activity. NOTE: Abatement certification and documentation are required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2016-10-27
Abatement Due Date 2016-11-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-02-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) On or about October 11, 2016 or prior thereto: Fall protection training provided by the employer did not include a discussion of fall protection to be utilized in the workplace when working from elevated levels. On October 11, 2016, employees were exposed to heights of approximately 25 feet without wearing fall protection. NOTE: Abatement certification and documentation are required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
1968147204 2020-04-15 1087 PPP 480 N Utah Ave, Idaho Falls, ID, 83402
Loan Status Date 2021-02-17
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 7798
Loan Approval Amount (current) 7798
Undisbursed Amount 0
Franchise Name -
Lender Location ID 96265
Servicing Lender Name Beehive FCU
Servicing Lender Address 1087 Erikson Dr, REXBURG, ID, 83440-5297
Rural or Urban Indicator U
Hubzone N
LMI Y
Business Age Description Existing or more than 2 years old
Project Address Idaho Falls, BONNEVILLE, ID, 83402-1200
Project Congressional District ID-02
Number of Employees 1
NAICS code 238220
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Sole Proprietorship
Originating Lender ID 96265
Originating Lender Name Beehive FCU
Originating Lender Address REXBURG, ID
Gender Male Owned
Veteran Veteran
Forgiveness Amount 7852.91
Forgiveness Paid Date 2021-01-07

Date of last update: 06 Apr 2025

Sources: Idaho Secretary of State