Name: | MGM General Construction LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 30 Mar 2020 (5 years ago) |
Financial Date End: | 31 Mar 2026 |
Entity Number: | 3821844 |
Place of Formation: | IDAHO |
File Number: | 704687 |
ZIP code: | 83607 |
County: | Canyon County |
Principal Address: | 22754 CHANNEL RD CALDWELL, ID 83607 |
Mailing Address: | 22754 CHANNEL RD CALDWELL, ID 83607-7756 |
Name | Role | Address | Appointed On | Resigned On |
---|---|---|---|---|
Mauro Garcia | Member | PO BOX 1001, CALDWELL, ID 83606 | 2024-02-28 | 2024-02-28 |
Name | Role | Address | Appointed On |
---|---|---|---|
Michael Morales | Manager | PO BOX 1001, CALDWELL, ID 83606 | 2021-02-04 |
Name | Role | Address |
---|---|---|
Shawn C Maybon | Agent | 904 DEARBORN, STE 204, CALDWELL, ID 83605 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0006097776 | 2025-02-05 |
Amendment to Certificate | 0005749013 | 2024-05-28 |
Annual Report | 0005615737 | 2024-02-28 |
Annual Report | 0005102608 | 2023-02-08 |
Annual Report | 0004595537 | 2022-02-04 |
Annual Report | 0004164597 | 2021-02-04 |
Statement of Change of Business Mailing Address | 0003885518 | 2020-05-28 |
Initial Filing | 0003821844 | 2020-03-30 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346868524 | 1032500 | 2023-07-25 | 3225 GREENHURST RD, NAMPA, ID, 83687 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1686726 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1686780 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1686690 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1686879 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19261153 C01 |
Issuance Date | 2023-12-11 |
Abatement Due Date | 2024-01-08 |
Current Penalty | 1992.2 |
Initial Penalty | 2846.0 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assessed and limited the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section. a) On July 24, 2023, and at times prior to; an employee cutting silica-containing James Hardie plank siding was using a Makita radial saw with a 7 1/4" HardieBlade which did not have a dust collection system, creating dust in the air around the employee performing the cutting. Note* Abatement certification is required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19261153 D02 I |
Issuance Date | 2023-12-11 |
Abatement Due Date | 2024-01-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section: a) On July 24, 2023, and at times prior to; employer did not assess the engineering and work practice controls in place to reduce respirable crystalline silica exposures for employees cutting James Hardie plank siding using Makita radial saws with 7 1/4" HardieBlades, and wearing N95 respirators. Note* Abatement certification is required for this item. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19261153 G01 |
Issuance Date | 2023-12-11 |
Abatement Due Date | 2024-01-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan: a) On July 24, 2023, and at times prior to, the employer's written exposure control plan was not fully implemented and did not describe the work practice controls to limit employee exposure to respirable crystalline silica dusts while cutting James Hardie plank siding using Makita radial saws with 7 1/4" HardieBlades. Note* Abatement certification is required for this item. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100134 E01 |
Issuance Date | 2023-12-11 |
Abatement Due Date | 2024-01-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103). a) On July 24, 2023, and at times prior to, an employee cutting James Hardie plank siding using a Makita radial saw with a James HardieBlade wore an N95 respirator but had not been medically evaluated. Note* Abatement certification is required for this item. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100134 F02 |
Issuance Date | 2023-12-11 |
Abatement Due Date | 2024-01-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (Construction Reference 1926.103) a) On July 24, 2023, and at times prior to, an employee cutting James Hardie plank siding using a Makita radial saw with a James HardieBlade wore an N95 respirator for protection from respirable crystalline silica but had not been fit tested. Note* Abatement certification is required for this item. |
Date of last update: 15 Apr 2025