Name: | Intermountain Packing, LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 04 Feb 2020 (5 years ago) |
Financial Date End: | 28 Feb 2026 |
Entity Number: | 3765515 |
Place of Formation: | IDAHO |
File Number: | 697708 |
ZIP code: | 83402 |
County: | Bonneville County |
Principal Address: | 3640 S YELLOWSTONE HWY IDAHO FALLS, ID 83402-4703 |
Mailing Address: | 1096 E IONA RD IDAHO FALLS, ID 83401-2170 |
Unique Entity ID | Expiration Date | Physical Address | Mailing Address | |||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZTVYSGRMP2E9 | 2023-12-16 | 1096 E IONA RD, IDAHO FALLS, ID, 83401, 2170, USA | 1096 E IONA RD, IDAHO FALLS, ID, 83401, 2170, USA | |||||||||||||||||||||||||||||||||||||||||||
|
URL | https://www.intermountainpacking.com/ |
Congressional District | 02 |
State/Country of Incorporation | ID, USA |
Activation Date | 2023-01-11 |
Initial Registration Date | 2022-12-15 |
Entity Start Date | 2020-02-24 |
Fiscal Year End Close Date | Dec 31 |
Service Classifications
NAICS Codes | 311611, 311612, 488991 |
Points of Contacts
Electronic Business | |
---|---|
Title | PRIMARY POC |
Name | CORY MARTIN |
Role | IT MANAGER |
Address | 1096 E IONA ROAD, IDAHO FALLS, ID, 83401, USA |
Government Business | |
---|---|
Title | PRIMARY POC |
Name | KADE SHELLEY |
Role | CFO |
Address | 1096 E IONA ROAD, IDAHO FALLS, ID, 83401, USA |
Past Performance | Information not Available |
---|
Name | Role | Address |
---|---|---|
David Adams | Agent | 1096 E IONA RD, IDAHO FALLS, ID 83401-2170 |
Name | Role | Address | Appointed On | Resigned On |
---|---|---|---|---|
David G Adams | Member | 1096 E IONA ROAD, IDAHO FALLS, ID 83401 | 2023-03-15 | No data |
DAVID ADAMS | Member | 3640 S YELLOWSTONE HWY, IDAHO FALLS, ID 83402-4703 | 2022-01-06 | 2023-03-15 |
BRIGHAM BALL | Member | 3640 S YELLOWSTONE HWY, IDAHO FALLS, ID 83402-4703 | 2021-02-23 | No data |
David Adams | Member | 1096 E. IONA ROAD, IDAHO FALLS, ID 83401 | 2025-03-21 | No data |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0006167104 | 2025-03-21 |
Application for Reinstatement | 0005731350 | 2024-05-08 |
Dissolution/Revocation - Administrative | 0005726823 | 2024-05-07 |
Change of Registered Office/Agent/Both (by Entity) | 0005688298 | 2024-04-25 |
Annual Report | 0005157332 | 2023-03-15 |
Annual Report | 0004556936 | 2022-01-06 |
Annual Report | 0004181074 | 2021-02-23 |
Initial Filing | 0003765515 | 2020-02-04 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347174807 | 1032500 | 2023-12-14 | 625 PANCHERI DR, IDAHO FALLS, ID, 83401 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2024-05-24 |
Abatement Due Date | 2024-06-06 |
Current Penalty | 8296.0 |
Initial Penalty | 8296.0 |
Final Order | 2024-06-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees where employees were exposed to fall hazards when elevated in a man-basket attached to the forks of a powered industrial truck: a) Cold Storage Warehouse: On December 14, 2023, and at times prior to; employees were exposed to falls from approximately 20 feet to the concrete ground below while elevated in a man-basket, which had visible structural damage to the welds, attached to the forks of the Nissan Forklift, Model Number MCT1B2L25S. Note* Abatement certification is required for this item. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100178 A04 |
Issuance Date | 2024-05-24 |
Abatement Due Date | 2024-06-06 |
Current Penalty | 6222.0 |
Initial Penalty | 6222.0 |
Final Order | 2024-06-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) Cold Storage Warehouse: On December 14, 2023, and at times prior to; employees worked out of a man-basket attached to a Nissan Forklift, Model Number MCT1B2L25S. The front-end attachment had rust damage on the corner welds, which could affect the structural integrity of the man-basket. Note* Abatement certification is required for this item. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100178 A05 |
Issuance Date | 2024-05-24 |
Abatement Due Date | 2024-06-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-06-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) Cold Storage Warehouse: On December 14, 2023 and at times prior to; employees worked out of a man-basket attached to a Nissan Forklift, Model Number MCT1B2L25S. The front-end attachment had rust damage on the corner welds, which could affect the structural integrity of the man-basket. Note* Abatement certification is required for this item. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100178 L04 III |
Issuance Date | 2024-05-24 |
Abatement Due Date | 2024-06-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-06-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Cold Storage Warehouse: On December 14, 2023 and at times prior to; an employee operates forklifts to store, organize, and retrieve frozen meats and ice-cream from a tiered racking system. Training had been expired for approximately six months. Note* Abatement certification is required for this item. |
Date of last update: 14 Apr 2025
Sources: Idaho Secretary of State