Search icon

Intermountain Packing, LLC

Company Details

Name: Intermountain Packing, LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 04 Feb 2020 (5 years ago)
Financial Date End: 28 Feb 2026
Entity Number: 3765515
Place of Formation: IDAHO
File Number: 697708
ZIP code: 83402
County: Bonneville County
Principal Address: 3640 S YELLOWSTONE HWY IDAHO FALLS, ID 83402-4703
Mailing Address: 1096 E IONA RD IDAHO FALLS, ID 83401-2170

Unique Entity ID

Unique Entity ID Expiration Date Physical Address Mailing Address
ZTVYSGRMP2E9 2023-12-16 1096 E IONA RD, IDAHO FALLS, ID, 83401, 2170, USA 1096 E IONA RD, IDAHO FALLS, ID, 83401, 2170, USA

Business Information

URL https://www.intermountainpacking.com/
Congressional District 02
State/Country of Incorporation ID, USA
Activation Date 2023-01-11
Initial Registration Date 2022-12-15
Entity Start Date 2020-02-24
Fiscal Year End Close Date Dec 31

Service Classifications

NAICS Codes 311611, 311612, 488991

Points of Contacts

Electronic Business
Title PRIMARY POC
Name CORY MARTIN
Role IT MANAGER
Address 1096 E IONA ROAD, IDAHO FALLS, ID, 83401, USA
Government Business
Title PRIMARY POC
Name KADE SHELLEY
Role CFO
Address 1096 E IONA ROAD, IDAHO FALLS, ID, 83401, USA
Past Performance Information not Available

Agent

Name Role Address
David Adams Agent 1096 E IONA RD, IDAHO FALLS, ID 83401-2170

Member

Name Role Address Appointed On Resigned On
David G Adams Member 1096 E IONA ROAD, IDAHO FALLS, ID 83401 2023-03-15 No data
DAVID ADAMS Member 3640 S YELLOWSTONE HWY, IDAHO FALLS, ID 83402-4703 2022-01-06 2023-03-15
BRIGHAM BALL Member 3640 S YELLOWSTONE HWY, IDAHO FALLS, ID 83402-4703 2021-02-23 No data
David Adams Member 1096 E. IONA ROAD, IDAHO FALLS, ID 83401 2025-03-21 No data

Filing

Filing Name Filing Number Filing date
Annual Report 0006167104 2025-03-21
Application for Reinstatement 0005731350 2024-05-08
Dissolution/Revocation - Administrative 0005726823 2024-05-07
Change of Registered Office/Agent/Both (by Entity) 0005688298 2024-04-25
Annual Report 0005157332 2023-03-15
Annual Report 0004556936 2022-01-06
Annual Report 0004181074 2021-02-23
Initial Filing 0003765515 2020-02-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347174807 1032500 2023-12-14 625 PANCHERI DR, IDAHO FALLS, ID, 83401
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-12-14
Emphasis L: FORKLIFT, P: FORKLIFT
Case Closed 2024-08-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2024-05-24
Abatement Due Date 2024-06-06
Current Penalty 8296.0
Initial Penalty 8296.0
Final Order 2024-06-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees where employees were exposed to fall hazards when elevated in a man-basket attached to the forks of a powered industrial truck: a) Cold Storage Warehouse: On December 14, 2023, and at times prior to; employees were exposed to falls from approximately 20 feet to the concrete ground below while elevated in a man-basket, which had visible structural damage to the welds, attached to the forks of the Nissan Forklift, Model Number MCT1B2L25S. Note* Abatement certification is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100178 A04
Issuance Date 2024-05-24
Abatement Due Date 2024-06-06
Current Penalty 6222.0
Initial Penalty 6222.0
Final Order 2024-06-24
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) Cold Storage Warehouse: On December 14, 2023, and at times prior to; employees worked out of a man-basket attached to a Nissan Forklift, Model Number MCT1B2L25S. The front-end attachment had rust damage on the corner welds, which could affect the structural integrity of the man-basket. Note* Abatement certification is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100178 A05
Issuance Date 2024-05-24
Abatement Due Date 2024-06-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-06-24
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) Cold Storage Warehouse: On December 14, 2023 and at times prior to; employees worked out of a man-basket attached to a Nissan Forklift, Model Number MCT1B2L25S. The front-end attachment had rust damage on the corner welds, which could affect the structural integrity of the man-basket. Note* Abatement certification is required for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 L04 III
Issuance Date 2024-05-24
Abatement Due Date 2024-06-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-06-24
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Cold Storage Warehouse: On December 14, 2023 and at times prior to; an employee operates forklifts to store, organize, and retrieve frozen meats and ice-cream from a tiered racking system. Training had been expired for approximately six months. Note* Abatement certification is required for this item.

Date of last update: 14 Apr 2025

Sources: Idaho Secretary of State