Search icon

ANDERSON CABINET & MILLWORK, INC.

Company Details

Name: ANDERSON CABINET & MILLWORK, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 19 Dec 1997 (27 years ago)
Financial Date End: 31 Dec 2018
Date dissolved: 16 Apr 2019
Entity Number: 374388
Place of Formation: IDAHO
File Number: 374388
ZIP code: 83442
County: Jefferson County
Mailing Address: 198 N 4700 E RIGBY, ID 83442

Agent

Name Role Address
KEN ANDERSON Agent 198 N 4700 E, RIGBY, ID 83442

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0003480998 2019-04-16
Annual Report 0002604209 2017-11-24
Annual Report 0002604207 2016-11-04
Annual Report 0002604205 2015-10-30
Annual Report 0002604203 2014-12-08
Annual Report 0002604213 2013-10-30
Annual Report 0002604212 2012-10-24
Annual Report 0002604198 2011-10-11
Annual Report 0002604197 2010-10-07
Annual Report 0002604196 2009-10-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339850430 1032500 2014-07-15 198 N. 4700 E., RIGBY, ID, 83442
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-07-15
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2014-09-25
331110932 1032500 2012-01-05 198 N. 4700 E., RIGBY, ID, 83442
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2012-01-05
Emphasis N: AMPUTATE, N: SSTARG11
Case Closed 2013-06-11

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 1100.0
Initial Penalty 2100.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer. a) Paint booth: On or about January 5, 2012 and at times prior thereto, the employer did not develop a written respiratory protection program for employee required to wear elastomeric air purifying respirators. Note: Abatement certification is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 D01 III
Issuance Date 2012-04-20
Abatement Due Date 2012-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace, including a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. a) Paint booth: On or about January 5, 2012 and at times prior thereto, the employer did not identify and evaluate airborne exposures to spray finishes. Note: Abatement certification is required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. a) Paint booth: On or about January 5, 2012 and at times prior thereto, the employer did not provide medical evaluations for employees required to use elastomeric air purifying respirators. Note: Abatement certification is required for this item.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph. a) Paint booth: On or about January 5, 2012 and at times prior thereto, the employer had not conducted fit testing for employees required to use elastomeric air purifying respirators. Note: Abatement certification is required for this item.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 27
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet in the workplace for each hazardous chemical which they used. a) Paint booth: On or about January 5, 2012 and at times prior thereto, there was no MSDS for the wood stain being used. Note: Abatement certification is required for this item.
Citation ID 01001F
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. a) Paint booth: On or about January 5, 2012 and at times prior thereto, the employees had not been trained on the hazards associated with stains and spray coatings. Note: Abatement certification is required for this item.
Citation ID 02001A
Citaton Type Other
Standard Cited 19100095 C01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program, as described in paragraphs (c) through (o) of this section, whenever employee noise exposures equaled or exceeded an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale (slow response). a) Paint booth: On or about January 5, 2012 and at times prior thereto, there was no hearing conservation program where employees were exposed to continuous noise averaged at 87.8 decibels. Note: Abatement certification is required for this item.
Citation ID 02001B
Citaton Type Other
Standard Cited 19100095 D01
Issuance Date 2012-04-20
Abatement Due Date 2012-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(d)(1): The employer did not develop and implement a monitoring program, when information indicated that any employee's exposure may equal or exceed an 8-hour time-weighted average of 85 decibels. a) Paint booth: On or about January 5, 2012 and at times prior thereto, a monitoring program was not developed where employees were exposed to an average noise level of 87.8 decibels. Note: Abatement certification is required for this item.
Citation ID 02001C
Citaton Type Other
Standard Cited 19100095 G01
Issuance Date 2012-04-20
Abatement Due Date 2012-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided in this paragraph by making audiometric testing available to all employees whose exposures equaled or exceeded an 8-hour time-weighted average of 85 decibels. a) Paint booth: On or about January 5, 2012 and at times prior thereto, the employer had not conducted annual audiograms where employees were exposed to noise levels of 87.8 decibels. Note: Abatement certification is required for this item.
Citation ID 02001D
Citaton Type Other
Standard Cited 19100095 K01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(k)(1): The employer did not train each employee who was exposed to noise at or above an 8-hour time weighted average of 85 decibels in accordance with the requirements of this section. a) Paint booth: On or about January 5, 2012 and at times prior thereto, the employer did not train employees, who were exposed to noise levels of 87.8 decibels, on the requirements of a hearing conservation program. Note: Abatement certification is required for this item.
331112441 1032500 2012-01-05 198 N. 4700 E., RIGBY, ID, 83442
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-01-05
Emphasis N: SSTARG11
Case Closed 2013-06-11

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100036 E02
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 1100.0
Initial Penalty 2100.0
Final Order 2012-05-04
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.36(e)(2): Door(s) that connect any room to an exit route must swing out in the direction of exit travel if the room is designed to be occupied by more than 50 people or if the room is a high hazard area: a) East side of main shop: On January 5, 2012 and times prior thereto the exit door opened inward. b) North side of custom shop: On January 5, 2012 and times prior thereto the exit door opened inward. c) South side of custom shop: On January 5, 2012 and times prior thereto the exit door opened inward. Note) Abatement certification IS required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100037 A03
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(3): Exit routes were not free and unobstructed. Materials or equipment were placed, either permanently or temporarily, within the exit route: a) East side of main shop: On January 5, 2012 and times prior thereto materials stored on shelves located next to the exit door, extended into the exit path. b) South side of custom shop: On January 5, 2012 and times prior thereto a work bench and cabinets in the process of being built were located in the exit path. Note) Abatement certification IS required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100037 B02
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) East side of main shop: On January 5, 2012 and times prior thereto the exit was not marked. b) North side of custom shop: On January 5, 2012 and times prior thereto the exit was not marked. c) South side of custom shop: On January 5, 2012 and times prior thereto the exit was not marked. Note) Abatement certification IS required for this item.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100157 C01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(c)(1): The employer did not provide portable fire extinguishers and did not mount, locate and identify them so that they were readily accessible to employees without subjecting the employees to possible injury: a) North side of custom shop: On January 5, 2012 and times prior thereto the portable fire extinguisher for this area was located on the floor behind building materials and propane tanks. b) South side of custom shop: On January 5, 2012 and times prior thereto the portable fire extinguisher for this area was located behind a work bench. c) Custom shop, outside of office: On January 5, 2012 and times prior thereto the portable fire extinguisher mounted on the wall was not identified. Note) Abatement certification IS required for this item.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19100157 E02
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(e)(2): Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section were not inspected monthly: a) Assembly area: On January 5, 2012 and times prior thereto the employer did not have a system in place to ensure that all portable fire extinguishers available for use by employees were inspected for serviceability on a monthly basis. Note) Abatement certification IS required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100107 B01
Issuance Date 2012-04-20
Abatement Due Date 2012-08-01
Current Penalty 1100.0
Initial Penalty 2100.0
Final Order 2012-05-04
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(1): Spray booth was not constructed of steel, securely and rigidly supported, or of concrete or masonry: a) Spray finish area: On January 5, 2012 and times prior thereto the spray booth in use was constructed of oriented strand board (OSB) material or similar wood product. Note) Abatement certification IS required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100107 B02
Issuance Date 2012-04-20
Abatement Due Date 2012-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(2): The interior surfaces of the spray booth were not smooth and continuous without edges and otherwise designed to prevent pocketing of residues and facilitate cleaning and washing without injury: a) Spray finish area: On January 5, 2012 and times prior thereto the interior of the spray booth in use had openings and other surfaces that would allow escape and/or pocketing of overspray residues. Note) Abatement certification IS required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100107 F04
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(f)(4): An adequate supply of suitable portable fire extinguishers were not installed near all spraying areas: a) Finish area: On January 5, 2012 and times prior thereto there were no portable fire extinguishers located near the spray booth, or in the spray booth area. NOTE) Abatement certification IS required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2012-05-04
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was not isolated from the energy source and rendered inoperative: a) Custom shop: On January 5, 2012 and times prior thereto the employer had not developed and implemented an energy control program for the employees who perform activities which include, but are not limited to, clean up inside the cage area of the GIBON CUTTER and scheduled or unscheduled maintenance on the ALTENDORF table saw, or to provide awareness to those employees who may be affected by these activities in their work areas. Note) Abatement certification IS required for this item.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100212 A02
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2012-05-04
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(2): Guards were not affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible: a) Custom shop, router table: On January 5, 2012 and times prior thereto a guard was not in place on the rotating router bit when in use. b) Main shop, molding machine: On January 5, 2012 and times prior thereto a guard was not in place on the pulley assembly located at the back of the machine. Note) Abatement certification IS required for this item.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100213 C01
Issuance Date 2012-04-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(1): Each circular hand-fed ripsaw was not guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut: a) Custom shop: On or about January 5, 2012 and times prior thereto the hood/guard was not in place when the JET table saw was in use. Note) Abatement certification is NOT required for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19100303 G01 II
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1)(ii): Sufficient access and working space about electrical equipment required by this standard was used for storage: a) East side of assembly shop: On January 5, 2012 and times prior thereto the area directly in front of the circuit breaker panel was used for storage of excess materials and equipment. Note) Abatement certification IS required for this item.
Citation ID 02002A
Citaton Type Other
Standard Cited 19100305 B01 II
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed: a) South wall of main shop: On January 5, 2012 and times prior thereto the electrical power box located on the water tank pressure line was missing a knockout plug. b) North wall of main shop: On January 5, 2012 and times prior thereto an unused opening on an electrical cabinet was not effectively closed. Note) Abatement certification IS required for this item.
Citation ID 02002B
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2012-04-20
Abatement Due Date 2012-05-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-04
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)[A]: Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used for permanent wiring: a) Assembly shop: On January 5, 2012 and times prior thereto a flexible cord and/or cable was used for the GRASS door hinging machine. Note) Abatement certification IS required for this item.
311575203 1032500 2008-03-04 138 N MAIN, VICTOR, ID, 83455
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2008-03-04
Emphasis S: YOUTH, S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR, L: FALL
Case Closed 2008-05-09

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2008-04-22
Abatement Due Date 2008-05-02
Current Penalty 375.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2008-04-22
Abatement Due Date 2008-04-28
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01001C
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2008-04-22
Abatement Due Date 2008-04-28
Nr Instances 1
Nr Exposed 2
Gravity 01