Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-07-11
|
Emphasis |
L: FALL
|
Case Closed |
2019-08-27
|
Related Activity
Type |
Referral |
Activity Nr |
1476020 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1415526 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19260021 B02 |
Issuance Date |
2019-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
1932.0 |
Final Order |
2019-08-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) 1961 W Franklin Rd, Meridian, ID 83642: On or about July 11, 2019 and at times prior thereto; employees were exposed to housekeeping conditions that could result in slips, trips and falls, and/or impalement hazards. b) 1961 W Franklin Rd, Meridian, ID 83642: On or about July 11, 2019 and at times prior thereto; employees were exposed to fall hazards at approximately 10 feet. c) 1961 W Franklin Rd, Meridian, ID 83642: On or about July 11, 2019 and at times prior thereto; employees were exposed to the hazards of slips, trips and falls, and/or impalement hazards while accessing a ladder to the second floor. Note* Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260025 A |
Issuance Date |
2019-08-02 |
Current Penalty |
966.0 |
Initial Penalty |
0.0 |
Final Order |
2019-08-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: North, East and West sides of multi-family residential construction site: On July 11, 2019 and at times prior thereto; exterior areas surrounding access points, ladder access point, and exterior work areas had construction debris, and impalement hazards creating a slip/trip hazard. Note* Abatement certification IS required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-08-02 |
Current Penalty |
1449.0 |
Initial Penalty |
2898.0 |
Final Order |
2019-08-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 1961 W Franklin Rd, Meridian, ID 83642: On or about July 11, 2019 and at times prior thereto; employees performed subfloor installation work using pneumatic nail guns at a 10 foot height. Note* Abatement certification IS required for this item. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2019-08-02 |
Current Penalty |
1449.0 |
Initial Penalty |
2898.0 |
Final Order |
2019-08-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about July 11, 2019 and at times prior thereto; an extension ladder was used to access a second story subfloor and the ladder extended approximately 2 feet above the landing surface. Note* Abatement certification IS required for this item. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2019-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-08-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). a) On or about July 11, 2019 and at times prior thereto; an extension ladder used to access a second story subfloor at approximately 10 feet was not placed at a 4:1 distance. Note* Abatement certification IS required for this item. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19261053 B06 |
Issuance Date |
2019-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-08-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a) On or about July 11, 2019 and at times prior thereto; an extension ladder placed on loose, sloping soil was not secured, and was used to access a second story subfloor. Note* Abatement certification IS required for this item. |
|
|