Search icon

BOISE BUILDING COMPANY LLC

Company Details

Name: BOISE BUILDING COMPANY LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 21 Nov 2012 (12 years ago)
Financial Date End: 30 Nov 2023
Date dissolved: 01 Mar 2024
Entity Number: 366254
Place of Formation: IDAHO
File Number: 366254
ZIP code: 83616
County: Ada County
Principal Address: 247 W RIVERBRIDGE LN EAGLE, ID 83616
Mailing Address: 4186 W HOUSELAND CT EAGLE, ID 83616-2150

Agent

Name Role Address
MIKE SHANNAHAN Agent 4186 W HOUSELAND CT, EAGLE, ID 83616

Manager

Name Role Address Appointed On
mike shannahan Manager 4186 HOUAELAND CT, RAGLE, ID 83616 2020-10-03

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0005619038 2024-03-01
Annual Report 0004931988 2022-10-03
Annual Report 0004443537 2021-10-11
Annual Report Amendment 0004262034 2021-05-03
Change of Registered Office/Agent/Both (by Entity) 0004121686 2021-01-07
Annual Report 0004020194 2020-10-03
Amendment to Certificate 0003756902 2020-01-29
Annual Report 0003688054 2019-11-29
Annual Report 0003350278 2018-11-19
Legacy Amendment 0000872964 2018-05-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344110812 1032500 2019-06-25 3580 W HIDDEN SPRINGS DR, BOISE, ID, 83714
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2019-06-25
Emphasis L: FALL
Case Closed 2019-07-02

Related Activity

Type Inspection
Activity Nr 1411076
Safety Yes
344110713 1032500 2019-06-24 3568 W HIDDEN SPRINGS DR, BOISE, ID, 83714
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2019-06-25
Emphasis L: FALL
Case Closed 2019-08-06

Related Activity

Type Inspection
Activity Nr 1410415
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2019-06-26
Abatement Due Date 2019-07-23
Current Penalty 1137.0
Initial Penalty 2273.0
Final Order 2019-07-19
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): (a) On or about June 24, and at times prior thereto, this controlling employer did not conduct safety inspections of sufficient detail and frequency to identify and correct serious hazards. NOTE: Certification of corrective action is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-06-26
Abatement Due Date 2019-07-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-07-19
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Employees of a framing subcontractor were exposed to fall hazards while installing sheathing on a new wood frame single family home with an eave height of 11 feet and heights at the peak over 17 feet. NOTE: Abatement certification is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2019-06-26
Abatement Due Date 2019-07-23
Current Penalty 852.0
Initial Penalty 1705.0
Final Order 2019-07-19
Nr Instances 2
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: (a) Employees of a framing subcontractor were exposed to fall hazards when climbing wood-framed walls to access trusses in order to install sheathing. The new home had an eave height of 11 feet. (b) Employees of a framing subcontractor accessed the main floor of this new home 25 inches above the concrete at ground level by walking up and down two unsecured 2x6 boards. NOTE: Abatement certification is NOT required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
8700957103 2020-04-15 1087 PPP 1159 IRON DR E, EAGLE, ID, 83616
Loan Status Date 2021-06-18
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 70869
Loan Approval Amount (current) 70869
Undisbursed Amount 0
Franchise Name -
Lender Location ID 53803
Servicing Lender Name U.S. Bank, National Association
Servicing Lender Address 425 Walnut St, CINCINNATI, OH, 45202-3956
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address EAGLE, ADA, ID, 83616-0001
Project Congressional District ID-01
Number of Employees 8
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 53803
Originating Lender Name U.S. Bank, National Association
Originating Lender Address CINCINNATI, OH
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 71622.97
Forgiveness Paid Date 2021-05-06

Date of last update: 05 Apr 2025

Sources: Idaho Secretary of State