Search icon

OKLY CONSTRUCTION LLC

Company Details

Name: OKLY CONSTRUCTION LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 18 Oct 2012 (13 years ago)
Financial Date End: 31 Oct 2025
Entity Number: 363362
Place of Formation: IDAHO
File Number: 363362
ZIP code: 83607
County: Canyon County
Principal Address: 5210 DYNASTY AVE CALDWELL, ID 83607
Mailing Address: 5210 DYNASTY AVE CALDWELL, ID 83607-5186

Agent

Name Role Address
ORALIA DOMINGUEZ Agent 318 CALDWELL BLVD, NAMPA, ID 83651

Member

Name Role Address Appointed On Resigned On
Manuel Ramirez Member 16875 LIVE OAK PL, CALDWELL, ID 83607 2023-09-21 No data
Juan M Ramirez Member 5210 DYNASTY AVE, CALDWELL, ID 83607 2023-09-21 No data
Oralia Dominguez Member 5210 DYNASTY AVE, CALDWELL, ID 83607 2020-10-22 2023-09-21

Filing

Filing Name Filing Number Filing date
Annual Report 0005900106 2024-09-13
Annual Report 0005407749 2023-09-21
Annual Report 0004885654 2022-09-06
Annual Report 0004426735 2021-09-24
Annual Report 0004040155 2020-10-22
Amendment to Certificate 0003750374 2020-01-20
Annual Report 0003618147 2019-09-09
Annual Report 0002554525 2018-08-24
Annual Report 0002554524 2017-09-05
Annual Report 0002554523 2016-09-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342990272 1032500 2018-02-16 SKY MESA - LAGRANGE BLK9 LOT10, MERIDIAN, ID, 83646
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-02-16
Case Closed 2019-09-24

Related Activity

Type Referral
Activity Nr 1315236
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B01
Issuance Date 2018-05-08
Abatement Due Date 2018-06-04
Current Penalty 1400.0
Initial Penalty 2772.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: (a) Block 9 Lot 10 Sky Mesa Subdivision: On and before February 16, 2018 an outlet box with a broken face plate and exposed terminal screws was used by the employer as a portable distribution box to energize electrical equipment used by employees. Note: Abatement certification is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260403 B01 I
Issuance Date 2018-05-08
Abatement Due Date 2018-06-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. (a) Block 9 Lot 10 Sky Mesa Subdivision: On and before February 16, 2018 an outlet box intended for interior use was used by the employer as a portable distribution box to energize electrical equipment used by employees. Note: Abatement certification is required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260405 J01 V
Issuance Date 2018-05-08
Abatement Due Date 2018-06-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(j)(1)(v): Fixtures installed in wet or damp locations were not identified for the purpose, and were not installed so that water cannot enter or accumulate in wireways, lampholders, or other electrical parts: (a) Block 9 Lot 10 Sky Mesa Subdivision: On and before February 16, 2018 the outlet box intended for interior use was used by the employer as a portable distribution box to energize electrical equipment used by employees under wet conditions. Note: Abatement certification is required for this item.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260100 A
Issuance Date 2018-05-08
Abatement Due Date 2018-06-04
Current Penalty 2500.0
Initial Penalty 3326.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a) Block 9 Lot 10 Sky Mesa Subdivision: On and before February 16, 2018 employees on the ground were handing decking to workers performing sheathing activities on the roof were not wearing hard hats. Okly Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.100(a), which was contained in OSHA inspection number 909032 citation number 2 item number 1 and was affirmed as a final order on 6/20/13 with respect to a workplace located at Lot 10 Block 1Henry Ford, Eagle, ID 83616 Note: Abatement certification AND supporting documentation are required for this item .
Citation ID 02002A
Citaton Type Repeat
Standard Cited 19260405 A02 II I
Issuance Date 2018-05-08
Abatement Due Date 2018-06-04
Current Penalty 0.0
Initial Penalty 5543.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: (a) Block 9 Lot 10 Sky Mesa Subdivision: On and around February 16, 2018 energized electrical cords powering circular saws ran through piles of waste wood and over sharp edges. Okly Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.405(a)(2)(ii)(I), which was contained in OSHA inspection number 1236446 citation number 1 item number 2a and was affirmed as a final order on 10/20/17 with respect to a workplace located at 3563 S. Pheasant Tail Way Boise ID, 83716. Note: Abatement certification AND supporting documentation are required for this item.
Citation ID 02002B
Citaton Type Repeat
Standard Cited 19260416 E01
Issuance Date 2018-05-08
Abatement Due Date 2018-06-04
Current Penalty 3100.0
Initial Penalty 0.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) Block 9 Lot 10 Sky Mesa Subdivision: On and around February 16, 2018 energized (110 volt) electrical extension cords powering a hand held circular saw was damaged. (b) Block 9 Lot 10 Sky Mesa Subdivision: On and around February 16, 2018 the electrical power cord of a circular saw was damaged. Power cord was connected to the damaged energized extension cord (110 volt). Okly Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.416(e)(1), which was contained in OSHA inspection number 1236446 citation number 1 item number 2b and was affirmed as a final order on 10/20/17 with respect to a workplace located at 3563 S. Pheasant Tail Way Boise ID, 83716. Note: Abatement certification AND supporting documentation are required for this item.
Citation ID 02003
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2018-05-08
Abatement Due Date 2018-06-04
Current Penalty 5000.0
Initial Penalty 6652.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Block 9 Lot 10 Sky Mesa Subdivision: On and around February 16, 2018 employees performing framing and sheathing activities are not protected from falls of 10 to 14 feet onto packed earth, concrete, and construction debris. Okly Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1236446 citation number 1 item number 1 and was affirmed as a final order on 10/20/17 with respect to a workplace located at 3563 S. Pheasant Tail Way Boise ID, 83716. Okly Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 909032 citation number 1 item number 1a and was affirmed as a final order on 6/20/13 with respect to a workplace located at Lot 10 Block 1 Henry Ford, Eagle, ID 83616 Note: Abatement certification AND supporting documentation are required for this item.
Citation ID 03001
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2018-05-08
Abatement Due Date 2018-06-04
Current Penalty 0.0
Initial Penalty 311.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Block 9 Lot 10 Sky Mesa Subdivision: On and before February 16, 2018 employees working at heights of 10 feet and above were not provided training concerning fall protection. Note: Abatement certification is required for this item.
342364460 1032500 2017-05-18 S. PHEASANT TRAIL WAY, BOISE, ID, 83716
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-05-18
Case Closed 2017-10-20

Related Activity

Type Referral
Activity Nr 1221634
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-06-22
Abatement Due Date 2017-07-19
Current Penalty 1086.5
Initial Penalty 2173.0
Final Order 2017-10-20
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 3563 S. Pheasant Tail Way: On or about May 11, 2017 and at times prior, at approximately 11 ft. employees were framing the second floor of a single family home. Note: Abatement certification is required for this document.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260405 A02 II I
Issuance Date 2017-06-22
Abatement Due Date 2017-07-19
Current Penalty 815.0
Initial Penalty 1630.0
Final Order 2017-10-20
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: (a) 3563 S. Pheasant Tail Way: On or about May 11, 2017 and at times prior, an electrical cord that powered circular saws was ran through a pile of waste wood. Note: Abatement certification is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2017-06-22
Abatement Due Date 2017-07-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-10-20
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) 3563 S. Pheasant Tail Way: On or about May 11, 2017 and at times prior, an electrical cord that powered circular saws was damaged.
Citation ID 02001
Citaton Type Other
Standard Cited 19260025 A
Issuance Date 2017-06-22
Abatement Due Date 2017-07-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-10-20
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: (a) 3563 S. Pheasant Tail Way: On or about May 11, 2017 and at times prior, work areas contained trip hazards from the accumulation of wood and other construction related debris. Note: Abatement certification is required for this item.
339090326 1032500 2013-05-15 LOT 10, BLOCK 1 HENRY FORD, EAGLE, ID, 83616
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-05-15
Emphasis L: FALL, L: RESCON
Case Closed 2013-07-30

Related Activity

Type Complaint
Activity Nr 821076
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-06-03
Abatement Due Date 2013-06-07
Current Penalty 1800.0
Initial Penalty 2000.0
Final Order 2013-06-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) Residential jobsite: On May 15, 2013 and at times prior thereto employees performed sheathing activities on a 8 in 12 pitched roof without a fall protection system in place. b) Back patio trusses: On May 15, 2013 and at times prior thereto employees performed framing activities while on the bottom cord of sheathed trusses with out an appropriate walkway or fall protection system in place. Note) Abatement certification IS required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2013-06-03
Abatement Due Date 2013-06-07
Current Penalty 0.0
Initial Penalty 1600.0
Final Order 2013-06-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Back patio: On May 15, 2013 and at times prior thereto employees used the top cap of an 8 foot self-supporting ladder for access to and from the bottom cord of a sheathed truss system. Note) Abatement certification IS required for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2013-06-03
Abatement Due Date 2013-06-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-06-20
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Jobsite: On May 15, 2013 and at times prior thereto an employee perfoming laborer activities on the ground for the sheathing activities above, was not wearing a hard hat. Note) Abatement certification IS required for this item.

Date of last update: 05 Apr 2025

Sources: Idaho Secretary of State