Name: | ARRIAGA BUILDING COMPANY LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 28 Aug 2019 (6 years ago) |
Financial Date End: | 31 Aug 2025 |
Entity Number: | 3608663 |
Place of Formation: | IDAHO |
File Number: | 678677 |
ZIP code: | 83605 |
County: | Canyon County |
Principal Address: | 401 W USTICK RD CALDWELL, ID 83605-6253 |
Name | Role | Address |
---|---|---|
MIKE CROW | Agent | 1204 6TH S N, NAMPA, ID 83687 |
Name | Role | Address | Appointed On |
---|---|---|---|
CARLOS ARRIAGA | Member | 401 W USTICK RD, CALDWELL, ID 83605 | 2020-08-13 |
Filing Name | Filing Number | Filing date |
---|---|---|
Application for Reinstatement | 0005820418 | 2024-07-24 |
Dissolution/Revocation - Administrative | 0005473661 | 2023-11-09 |
Annual Report | 0004948396 | 2022-10-10 |
Annual Report | 0004332765 | 2021-07-05 |
Annual Report | 0003971773 | 2020-08-13 |
Initial Filing | 0003608663 | 2019-08-28 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347523607 | 1032500 | 2024-05-30 | 13156 HAWK BAY, DONNELLY, ID, 83615 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 2169590 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2024-07-12 |
Abatement Due Date | 2024-07-18 |
Current Penalty | 1451.8 |
Initial Penalty | 2074.0 |
Final Order | 2024-09-06 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On May 30, 2024 and times prior, an employee performing framing activities using a pneumatic nail gun was not wearing eye protection that met ANSI Z-87 requirements Note) Certification of corrective action is required for this item. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-07-12 |
Current Penalty | 2419.9 |
Initial Penalty | 3457.0 |
Final Order | 2024-09-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On May 30, 2024, employees performing framing activities on the exterior top plate without fall protection were exposed to 10 to 20-foot fall hazards to the ground below. Note) Certification of corrective action is not required for this item. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2024-07-12 |
Abatement Due Date | 2024-07-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-09-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On May 30, 2024 and times prior, employees performing framing activities without fall protection were exposed to a 10 to 20-foot fall hazard to the ground below. The employees did not recognize the hazardous condition or take action to minimize their exposure. Note) Certification of corrective action is required for this item. |
Date of last update: 14 Apr 2025
Sources: Idaho Secretary of State