347650442
|
1032500
|
2024-07-29
|
3RD HOUSE ON LEFT E JARVIS CT, MERIDIAN, ID, 83642
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-07-29
|
Emphasis |
N: HEATNEP
|
Case Closed |
2024-09-06
|
Related Activity
Type |
Referral |
Activity Nr |
2209091 |
Safety |
Yes |
|
|
346227143
|
1032500
|
2022-09-15
|
1636 N MUMBARTO LANE, BOISE, ID, 83713
|
|
Inspection Type |
Unprog Rel
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2022-09-15
|
Emphasis |
L: FALL
|
Case Closed |
2022-09-15
|
Related Activity
Type |
Inspection |
Activity Nr |
1622718 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1622713 |
Safety |
Yes |
|
|
344107016
|
1032500
|
2019-06-24
|
9274 S PALENA PLACE, KUNA, ID, 83634
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-06-24
|
Emphasis |
L: FALL
|
Case Closed |
2019-11-12
|
Related Activity
Type |
Referral |
Activity Nr |
1469078 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2019-06-26 |
Current Penalty |
1000.0 |
Initial Penalty |
1705.0 |
Final Order |
2019-07-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a) A workers on the ground under framing activities such, including truss installation, was not wearing a hardhat and was exposed to being struck by tools and materials. NOTE: Abatement certification is NOT required for this item. Corrected on site. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2019-06-26 |
Current Penalty |
1000.0 |
Initial Penalty |
1705.0 |
Final Order |
2019-07-19 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: (a) Workers engaged in framing activities, including using saw and pneumatic nail guns, were not required to wear eye protection. NOTE: Certification of abatement is NOT required for this item. Corrected during inspection. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
1500.0 |
Initial Penalty |
2842.0 |
Final Order |
2019-07-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) An employee engaged in truss installation while framing a new residential unit was exposed to a 20 feet high fall hazard while walking the top plate with no fall protection. NOTE: Certification of Corrective Action is required for this item. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
1000.0 |
Initial Penalty |
1932.0 |
Final Order |
2019-07-19 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge: (a) Employees were exposed up to 10 feet high fall hazards when using unfinished stairs to the second level without a handrail or stair rail to the open sides. NOTE: Corrected during inspection. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19261052 C12 |
Issuance Date |
2019-06-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-19 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: (a) Employees were exposed to an approximate 10 feet high fall hazard from the landing at the top of unfinished interior stairs to the second level. NOTE: Corrected during inspection. |
|
|
339135212
|
1032500
|
2013-06-12
|
10315 COLORFUL DRIVE, NAMPA, ID, 83651
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-06-12
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2013-12-24
|
Related Activity
Type |
Referral |
Activity Nr |
823515 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-07-17 |
Abatement Due Date |
2013-07-23 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Jobsite: On or about June 12, 2013, employees observed involved in framing activities without any means of fall protection and exposed to a fall hazards on this multi story residential job. Note: Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2013-07-17 |
Abatement Due Date |
2013-07-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) On or about June 12, 2013, and times prior thereto the responsible person on site and employees performing framing activities did not recognize the hazards of working without fall protection, and take appropriate actions to minimize and/or eliminate these hazards. Note) Abatement certification IS required for this item. |
|
|