346521172
|
1032500
|
2023-02-22
|
901 NORTH 27TH STREET, BOISE, ID, 83702
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-02-22
|
Emphasis |
L: FALL, N: CTARGET, P: CTARGET
|
Case Closed |
2023-02-22
|
Related Activity
Type |
Inspection |
Activity Nr |
1652139 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1652119 |
Safety |
Yes |
|
|
345154587
|
1032500
|
2021-02-18
|
100 E BOWER ST., MERIDIAN, ID, 83642
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-02-18
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2021-09-30
|
Related Activity
Type |
Inspection |
Activity Nr |
1515454 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1515449 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2021-07-07 |
Abatement Due Date |
2021-08-02 |
Current Penalty |
4178.0 |
Initial Penalty |
4178.0 |
Final Order |
2021-08-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system: a) Fourth Floor Roof: On or about February 18, 2021 and at times prior thereto employees were exposed to 12 to 24 foot fall hazards while working from a flat roof. NOTE-Abatement documentation and certification are required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2021-07-07 |
Abatement Due Date |
2021-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-08-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) Fourth Floor Roof: On or about February 18, 2021 and at times prior thereto employees were exposed to 15 to 40 foot fall hazards while installing tongue and groove roofing material on a 2/12 pitch roof, and were not connected to their vertical lifeline, or self-retracting lanyard. NOTE-Abatement documentation and certification are required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260502 D11 |
Issuance Date |
2021-07-07 |
Abatement Due Date |
2021-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded: a) Fourth Floor Roof: On or about February 18, 2021 and at times prior thereto employees were exposed to 12 foot fall hazards, where a vertical lifeline was not protected against abrasion along a flat roof metal edge. NOTE-Abatement documentation and certification are required for this item. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 |
Issuance Date |
2021-07-07 |
Abatement Due Date |
2021-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii) a) On or about February 18, 2021 and at times prior thereto employees were installing a tongue and groove roof, at heights greater than six feet, and were not trained to identify the hazards, or to use a complete personal fall arrest system. NOTE-Abatement documentation and certification are required for this item. |
|
|
343463626
|
1032500
|
2018-09-12
|
4455 E. WARM SPRING AVE, BOISE, ID, 83716
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-09-12
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2018-09-12
|
|
340682814
|
1032500
|
2015-05-22
|
CHINDEN & MAPLE GROVE, GARDEN CITY, ID, 83703
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-05-22
|
Case Closed |
2015-10-01
|
Related Activity
Type |
Complaint |
Activity Nr |
989680 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2015-08-20 |
Abatement Due Date |
2015-09-16 |
Current Penalty |
1200.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-09-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. (a) At the site: On May 22, 2015 and at times prior thereto employees that erected the scaffold did not have training or experience to perform scaffold erection. Note: Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2015-08-20 |
Abatement Due Date |
2015-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) East side of structure: On May 22, 2015 employees engaged in work from the top platform of a scaffold were not adequately protected from fall hazards of 13.9 feet onto packed earth. Note: Abatement certification IS required for this item. |
|
|