Search icon

MACHINE DYNAMICS, INC.

Company Details

Name: MACHINE DYNAMICS, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 20 Nov 1995 (29 years ago)
Financial Date End: 30 Nov 2018
Date dissolved: 05 Mar 2019
Entity Number: 346983
Place of Formation: IDAHO
File Number: 346983
ZIP code: 83263
County: Franklin County
Mailing Address: 303 SOUTH STATE PRESTON, ID 83263

Agent

Name Role Address
REX PITCHER Agent 110 E VALLEY VIEW DR, PRESTON, ID 83263

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0003443451 2019-03-05
Annual Report 0002475938 2017-09-22
Annual Report 0002475936 2016-10-17
Annual Report 0002475934 2015-09-21
Annual Report 0002475932 2014-09-17
Annual Report 0002475930 2013-09-20
Annual Report 0002475952 2012-09-17
Annual Report 0002475948 2011-09-12
Annual Report 0002475947 2010-12-13
Annual Report 0002475946 2009-09-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339750994 1032500 2014-04-23 303 SOUTH STATE, PRESTON, ID, 83263
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-04-23
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2014-06-16

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100147 C04 I
Issuance Date 2014-05-20
Abatement Due Date 2014-06-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-17
Nr Instances 4
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. (a) CNC Mazak VTC 200B, serial 145511 (mill) (b) CNC Mazak Nexus 510C, serial 172324 (mill) (c) Mazatrol PC-Fusion CNC 640 (lathe) (d) MAZAK "Quick turn" Nexus 250. Note: Abatement certification IS required for this item.
Citation ID 01002
Citaton Type Other
Standard Cited 19100178 L06
Issuance Date 2014-05-20
Abatement Due Date 2014-06-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-17
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) There was no record/certification of training for the powered industrial truck operator. Note: Abatement certification IS required for this item.
Citation ID 01003
Citaton Type Other
Standard Cited 19100212 A03 IV E
Issuance Date 2014-05-20
Abatement Due Date 2014-06-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-17
Nr Instances 2
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(iv)(e): Employee(s) were using milling machines without point of operation guarding in place. (a) Interlock disconnected on the CNC Mazak VTC 200B, serial 145511 (mill). (b) Interlock disconnected on the CNC Mazak Nexus 510C, serial 172324 (mill). Note: Abatement certification IS required for this item.