Search icon

Bigfoot Framing LLC

Company Details

Name: Bigfoot Framing LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 26 Mar 2019 (6 years ago)
Financial Date End: 31 Mar 2026
Entity Number: 3462586
Place of Formation: IDAHO
File Number: 659842
Principal Address: CARLOS LOPEZ 19765 SUSQUEHANNA WAY CALDWELL, ID 83605
Mailing Address: CARLOS LOPEZ 19893 ADIRONDACK WAY CALDWELL, ID 83605-8053

Agent

Name Role Address
Carlos Lopez Agent 19893 ADIRONDACK WAY, CARLOS LOPEZ, CALDWELL, ID 83605-8053

Member

Name Role Address Appointed On Resigned On
Carlos Ponce Member 19893 ADIRONDACK WAY, CALDWELL, ID 83605 2020-10-23 2023-02-24
Carlos Lopez Member 19893 ADIRONDACK WAY, CALDWELL, ID 83605 2023-02-24 No data

Filing

Filing Name Filing Number Filing date
Annual Report 0006197756 2025-04-07
Annual Report 0005593363 2024-02-08
Annual Report 0005124488 2023-02-24
Annual Report 0004735853 2022-05-05
Annual Report 0004236430 2021-04-06
Application for Reinstatement 0004040929 2020-10-23
Dissolution/Revocation - Administrative 0003897957 2020-06-04
Initial Filing 0003462586 2019-03-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345769186 1032500 2022-02-08 1109 WEST LORRETTA STREET, MERIDIAN, ID, 83646
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2022-02-08
Emphasis L: FALL
Case Closed 2023-08-16

Related Activity

Type Referral
Activity Nr 1864220
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2022-02-10
Abatement Due Date 2022-02-16
Current Penalty 3600.0
Initial Penalty 5469.0
Final Order 2022-03-03
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels is not protected by guardrail systems, safety net system, or personal fall arrest system: a) Big Foot Framing does not ensure employees engaged in construction activities are protected from fall hazards. This violation was recently observed on February 8, 2022, where employees performed framing activities on a 6 in 12 pitched roof without a fall protection system in place. The employees were exposed to an 11.3 foot or more fall hazard to the concrete below. Bigfoot Framing, LLC was previously cited for a violation of this occupational safety and health standard, CFR 1926.501(b)(13), which was contained in OSHA inspection number 1471035, citation number 1, item number 1a, and was affirmed as a final order on June 23, 2020, with respect to a workplace located at 922 North Ash Pine Way, Meridian ID 83642. Note) Abatement certification AND supporting documentation ARE required for this item.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19261053 B01
Issuance Date 2022-02-10
Current Penalty 3600.0
Initial Penalty 5469.0
Final Order 2022-03-03
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders are used for access to an upper landing surface where the ladder side rails do not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) This employer does not ensure ladders extend at least three feet above the landing surface. This violation was most recently observed on February 8, 2022, employees used an extension ladder where only one rung was above the eave in order to access the sheathed roof. This exposed the employees to an 11.3 foot fall hazard to the concrete below. Bigfoot Framing, LLC was previously cited for a violation of this occupational safety and health standard, CFR 1926.1053(b)(1), which was contained in OSHA inspection number 1471035, citation number 1, item number 2, and was affirmed as a final order on June 23, 2020, with respect to a workplace located at 922 North Ash Pine Way, Meridian ID 83642. Note) Corrected during inspection.
344710355 1032500 2020-03-25 922 N ASH PINE WAY, MERIDIAN, ID, 83642
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2020-03-25
Emphasis L: FALL
Case Closed 2022-02-09

Related Activity

Type Complaint
Activity Nr 1558520
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2020-05-29
Abatement Due Date 2020-06-10
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2020-06-23
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On March 25, 2020; employees performing framing activities without fall protection in place, were exposed to fall hazards while working at heights ranging from approximately 11 to 22 feet. Note: Abatement certification and documentation are required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2020-05-29
Abatement Due Date 2020-06-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-23
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) On March 25, 2020; employees performing framing activities without fall protection in place, were exposed to fall hazards while working at heights ranging from approximately 11 to 22 feet. Note: Abatement certification and documentation are required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2020-05-29
Abatement Due Date 2020-06-10
Current Penalty 3470.0
Initial Penalty 3470.0
Final Order 2020-06-23
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On March 25, 2020; employees were exposed to falls of approximately 11 feet to the concrete floor while using a folded A-Frame ladder to access the second floor landing. The ladder was leaning against studs adjacent to and bellow the second floor landing. (b) On March 25, 2020; employees were exposed to falls of approximately 11 feet to the second floor landing while using a folded A-Frame ladder to access the second floor roof. The ladder was leaning adjacent to and bellow the second floor roof. Note: Abatement certification is required for this item.

Date of last update: 14 Apr 2025

Sources: Idaho Secretary of State