Search icon

J.L ROOFING

Company Details

Name: J.L ROOFING
Jurisdiction: Idaho
Legal type: Assumed Business Name
Status: Active-Current
Date of registration: 06 Jun 2007 (18 years ago)
Entity Number: 345033
Place of Formation: IDAHO
File Number: 0000345033
ZIP code: 83647
County: Elmore County
Mailing Address: 518 ELMCREST #6 MOUNTAIN HOME, ID 83647

Filing

Filing Name Filing Number Filing date
Initial Filing 0000345033 2007-06-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339046856 1032500 2013-05-06 16570 N. BROOKDALE PKWY, NAMPA, ID, 83687
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2013-05-06
Emphasis L: FALL, L: RESCON
Case Closed 2013-11-08

Related Activity

Type Referral
Activity Nr 817076
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-05-16
Abatement Due Date 2013-05-22
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-05-22
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about May 6, 2013, and at times prior thereto, two employees involved in roofing activities on a 6 in 12 pitch roof structure without a fall protection system and exposed to a fall hazard ranging from heights 10.6 feet up to 18 feet from the ground to eaves. NOTE: Abatement certification IS required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2013-05-16
Abatement Due Date 2013-05-22
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2013-05-22
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: (a) Front of the structure over the main garage: On or about May 6, 2013, and at times prior thereto, the employer did not provide a safe means of access/egress where there was a 3 1/2 foot break in elevation between roof levels. Note: Abatement certification IS required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-05-16
Abatement Due Date 2013-05-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-05-22
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. (a) In front of the structure above the main garage: On or about May 6, 2013, the extension ladder was only extended approximately 1 1/2 feet above the landing. Note: Abatement certification IS NOT required for this item.

Date of last update: 25 Sep 2024