338787435
|
1032500
|
2013-01-16
|
14444 E. LONE SHORE DRIVE, EAGLE, ID, 83616
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-01-16
|
Emphasis |
L: RESCON, L: FALL
|
Case Closed |
2013-07-30
|
Related Activity
Type |
Referral |
Activity Nr |
794132 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-02-11 |
Abatement Due Date |
2013-02-15 |
Current Penalty |
1600.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-03-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) 14444 E Lone Shore Drive, Eagle, ID: On or about January 16, 2013, employees observed appllying the chicken wire base in preparation for stucco activities without any means of fall protection and exposed to a fall hazards on this multi-story residential job. Note: Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 VIII |
Issuance Date |
2013-02-11 |
Abatement Due Date |
2013-02-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-03-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M: a) On or about January 16, 2013, and times prior thereto, employees performing stucco activities did not recognize the hazards of working without fall protection, and take appropriate actions to minimize and/or eliminate these hazards. Note) Abatement certification and documentation IS required for this item. |
|
|
309965556
|
1032500
|
2007-01-26
|
7316 FAIRVIEW AVENUE, BOISE, ID, 83704
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2007-01-31
|
Emphasis |
S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, L: FALL
|
Case Closed |
2007-03-16
|
Related Activity
Type |
Referral |
Activity Nr |
200244341 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2007-02-02 |
Abatement Due Date |
2007-02-07 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2007-02-02 |
Abatement Due Date |
2007-02-07 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2007-02-02 |
Abatement Due Date |
2007-02-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2007-02-02 |
Abatement Due Date |
2007-02-07 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
02 |
|
|