Name: | CLEARWATER CONTRACTING, LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 01 Feb 2012 (13 years ago) |
Financial Date End: | 28 Feb 2026 |
Entity Number: | 340914 |
Place of Formation: | IDAHO |
File Number: | 340914 |
ZIP code: | 83686 |
County: | Canyon County |
Principal Address: | 2618 BANNOCK NAMPA, ID 83686 |
Mailing Address: | BILL PRATHER 2618 BANNOCK AVE NAMPA, ID 83686-7934 |
Name | Role | Address |
---|---|---|
WILLIAM PRATHER | Agent | 2618 BANNOCK, NAMPA, ID 83686 |
Name | Role | Address | Appointed On |
---|---|---|---|
bill a prather | Member | 2618BANNOCKAVENUE, NAMPA, ID 83686 | 2021-02-07 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0006153663 | 2025-03-10 |
Annual Report | 0005552926 | 2024-01-09 |
Annual Report | 0005135587 | 2023-03-03 |
Annual Report | 0004624711 | 2022-02-28 |
Annual Report | 0004167334 | 2021-02-07 |
Application for Reinstatement | 0003873804 | 2020-05-11 |
Dissolution/Revocation - Administrative | 0003869847 | 2020-05-07 |
Annual Report | 0003414486 | 2019-01-28 |
Annual Report | 0002446743 | 2018-02-08 |
Annual Report | 0002446741 | 2017-03-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347295974 | 1032500 | 2024-02-22 | 100 SOUTH SHORT RD., EAGLE, ID, 83616 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
344106893 | 1032500 | 2019-06-25 | HIGHWAY 20/26 AND MIDDLETON ROAD, CALDWELL, ID, 83605 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1469040 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2019-09-16 |
Abatement Due Date | 2019-10-10 |
Current Penalty | 2000.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-10-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by and caught between hazard: (a) SW Corner of US Highway 20/26 and Middleton Rd.: On or about June 24, 2019 and at times prior, employees operate an American Auger Quick Split 42-600 horizontal boring machine to remove the spoils of a 27 inch casing that had been pushed under a roadway. Note: Abatement certification and documentation is required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260021 B02 |
Issuance Date | 2019-09-16 |
Abatement Due Date | 2019-10-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-10-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: (a) SW Corner of US Highway 20/26 and Middleton Rd.: On or about June 24, 2019 and at times prior, employees operate an American Auger Quick Split 42-600 horizontal boring machine to remove the spoils of a 27 inch casing that had been pushed under a roadway. Note: Abatement certification and documentation is required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260300 B01 |
Issuance Date | 2019-09-16 |
Abatement Due Date | 2019-10-10 |
Current Penalty | 2000.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-10-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: (a) SW Corner of US Highway 20/26 and Middleton Rd.: On or about June 24, 2019 and at times prior, employees operate an American Auger Quick Split 42-600 horizontal boring machine to remove the spoils of a 27 inch casing that had been pushed under a roadway. Note: Abatement certification and documentation is required for this item. |