342532074
|
1032500
|
2017-08-02
|
CAMEL KNOB SITE, PRIEST LAKE, ID, 83856
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-02
|
Emphasis |
L: LOGGING, P: LOGGING
|
Case Closed |
2017-12-07
|
Related Activity
Type |
Inspection |
Activity Nr |
1253252 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2017-09-19 |
Abatement Due Date |
2017-10-16 |
Current Penalty |
2154.6 |
Initial Penalty |
3078.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. a) On or about August 2, 2017 and at times prior thereto the Yarder operator was working at the edge of a steep grade, pulling logs from below, and was not wearing the provided seat belt. NOTE-Abatement certification is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100266 D03 I |
Issuance Date |
2017-09-19 |
Abatement Due Date |
2017-10-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(d)(3)(i): A seatbelt was not provided in each vehicle or machine equipped with ROPS/FOPS or with overhead guards. a) On or about August 2, 2017 and at times prior thereto the employer assigned a Volvo EC210bf log processor where no seat belt was provided. NOTE-Abatement certification is required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100266 H02 VI |
Issuance Date |
2017-09-19 |
Abatement Due Date |
2017-10-16 |
Current Penalty |
2154.6 |
Initial Penalty |
3078.0 |
Final Order |
2017-10-04 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(h)(2)(vi): The backcut did not leave sufficient hinge wood to hold the tree to the stump during most of its fall so that the hinge is able to guide the tree's fall in the intended direction. a) On or about August 2, 2017 and at times prior thereto trees were felled manually with a chain saw where a back cut was even with the face cut and did not contain sufficient hinge wood. NOTE-Abatement certification is required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100266 H02 VII |
Issuance Date |
2017-09-19 |
Abatement Due Date |
2017-10-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-04 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(h)(2)(vii): The backcut was not above the level of the horizontal facecut in order to provide an adequate platform to prevent kickback. a) On or about August 2, 2017 and at times prior thereto trees were felled manually with a chain saw where a back cut was even with, or below the face cut. NOTE-Abatement certification is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100266 F01 III |
Issuance Date |
2017-09-19 |
Abatement Due Date |
2017-10-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(f)(1)(iii): The employer did not assure that operating and maintenance instructions were available either on the machine or in the area where the machine was being operated: a) On or about August 2, 2017 and at times prior thereto a Volvo log processor was used to process logs at a landing where no operators manual was available. NOTE-Abatement certification is required for this item. |
|
|
342532181
|
1032500
|
2017-08-02
|
FLOSSMORE SITE, PRIEST LAKE, ID, 83856
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-02
|
Emphasis |
L: LOGGING, P: LOGGING
|
Case Closed |
2017-09-19
|
Related Activity
Type |
Inspection |
Activity Nr |
1253286 |
Health |
Yes |
|
|
342531985
|
1032500
|
2017-08-01
|
422 ELM STREET, PONDERAY, ID, 83852
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-03
|
Emphasis |
L: LOGGING, P: LOGGING
|
Case Closed |
2017-10-26
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 II |
Issuance Date |
2017-09-19 |
Abatement Due Date |
2017-10-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about April 12, 2017 and at times prior thereto a circuit breaker panel box was missing a blank for a circuit breaker exposing employees to electrical contact. Note-Abatement certification is required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2017-09-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: a) On or about April 12, 2017 and at times prior thereto the employer did not provide, or provide access to SDS's for chemicals ,including but not limited to 3M Brake Cleaner, WD-40, and NAPA CRC Electronic Cleaner. Note-Abatement certification is required for this item. |
|
|
342532520
|
1032500
|
2017-08-01
|
CAMEL KNOB SITE, COOLIN, ID, 83821
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-08-01
|
Emphasis |
L: LOGGING, P: LOGGING
|
Case Closed |
2017-09-14
|
Related Activity
Type |
Inspection |
Activity Nr |
1253207 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100266 D02 II |
Issuance Date |
2017-08-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-09-25 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(d)(2)(ii): Each first aid kit did not contain the items listed in Appendix A at all times: (a) Camel Knob: On or about August 2, 2017 and at times prior, employees were logging without a fully supplied first aid kit. The kit was missing tweezers, latex gloves, resuscitation equipment, triangular bandages, splint, and elastic wraps. Note: Abatement certification is NOT required. |
|
|
342532868
|
1032500
|
2017-08-01
|
FLOSSMAN SITE, PRIEST LAKE, ID, 83856
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-08-02
|
Emphasis |
L: LOGGING, P: LOGGING
|
Case Closed |
2017-08-02
|
Related Activity
Type |
Inspection |
Activity Nr |
1253218 |
Safety |
Yes |
|
|