336098991
|
1032500
|
2012-08-22
|
2161 W BELLAGIO DR, MERIDIAN, ID, 83646
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-22
|
Emphasis |
L: RESCON
|
Case Closed |
2012-08-22
|
|
330985177
|
1032500
|
2011-09-02
|
LOT 11, BLOCK 1 S. KNIGHTS BRIDGE LN.,, NAMPA, ID, 83687
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-09-02
|
Emphasis |
L: FALL
|
Case Closed |
2011-09-09
|
Related Activity
Type |
Referral |
Activity Nr |
78400 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
98512 |
Health |
Yes |
|
|
330969023
|
1032500
|
2011-07-20
|
LOT 5 BLOCK 37 PACHINO, MERIDIAN, ID, 83646
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-07-20
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2011-11-15
|
Related Activity
Type |
Referral |
Activity Nr |
77007 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2011-09-15 |
Abatement Due Date |
2011-09-16 |
Current Penalty |
1530.0 |
Initial Penalty |
1530.0 |
Final Order |
2011-10-04 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Jobsite: On July 20, 2011 and times prior thereto a four way metal junction box, wrapped in window flashing, was used to supply power to hand tools and an extension cord. Note) Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2011-09-15 |
Abatement Due Date |
2011-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-10-04 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Jobsite: On July 20, 2011 and times prior thereto the ground plugs were missing from the cords of three skilsaws in use on the jobsite. Note) Abatement certification IS required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2011-09-15 |
Abatement Due Date |
2011-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-10-04 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Jobsite: On July 20, 2011 and times prior thereto the power cord on a four way junction box had wires that were exposed and pulled away from the box where window flashing wrap was used for strain relief on the power cord. Note) Abatement certification IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19260501 B14 |
Issuance Date |
2011-09-15 |
Abatement Due Date |
2011-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
1530.0 |
Final Order |
2011-10-04 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: a) Jobsite: On July 20, 2011 and times prior thereto a guard rail system was not in place on the second floor window opening(s). Note) Abatement certification IS required for htis item. |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19260502 B02 IV |
Issuance Date |
2011-09-15 |
Abatement Due Date |
2011-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-10-04 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(2)(iv): Other structural members were installed such that there were openings in the guardrail system that were more than 19 inches (48 cm) wide: a) Jobsite: On JUly 20, 2011 and times prior thereto, employees were exposed to an approximate 10 foot fall hazard in an area used for access to/from the roof where the wall studs were approximately 22 inches apart without a guardrail system in place. Note) Abatement certification IS required for this item. |
|
|
313352387
|
1032500
|
2010-03-03
|
LOT 10, BLOCK 16, PINEWOOD LAKES, STAR, ID, 83669
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-03-03
|
Emphasis |
S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT, L: RESCON, L: FALL
|
Case Closed |
2010-05-10
|
Related Activity
Type |
Referral |
Activity Nr |
200249431 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2010-03-05 |
Abatement Due Date |
2010-03-10 |
Current Penalty |
500.0 |
Initial Penalty |
1600.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
02 |
|
|
309971885
|
1032500
|
2008-03-05
|
2095 W. PIAZZA STREET, MERIDIAN, ID, 83642
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2008-03-05
|
Emphasis |
L: FALL, S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT, L: RESCON
|
Case Closed |
2008-03-31
|
Related Activity
Type |
Referral |
Activity Nr |
200246395 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2008-03-06 |
Abatement Due Date |
2008-03-11 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2008-03-06 |
Abatement Due Date |
2008-03-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
306439837
|
1032500
|
2004-07-20
|
LOT 2 BLK 15, MERIDIAN, ID, 83642
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2004-07-20
|
Emphasis |
L: FALL
|
Case Closed |
2004-07-20
|
Related Activity
Type |
Referral |
Activity Nr |
200240281 |
Safety |