Search icon

Mountain Creek Siding LLC

Company Details

Name: Mountain Creek Siding LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Inactive-Dissolved
Date of registration: 01 Oct 2018 (7 years ago)
Financial Date End: 31 Oct 2021
Date dissolved: 02 Apr 2021
Entity Number: 3304141
Place of Formation: IDAHO
File Number: 637857
ZIP code: 83706
County: Ada County
Principal Address: 737 THRIFTYWAY ONTARIO, OR 97914
Mailing Address: 4621 W IRVING ST BOISE, ID 83706-2210

Agent

Name Role Address
Marianne Chaney Agent 106 W MAIN ST STE C, MIDDLETON, ID 83644

Manager

Name Role Address Appointed On
Jose Juarez Ramirez Manager 4621 W IRVING ST, BOISE, ID 83706-2210 2020-10-01

Filing

Filing Name Filing Number Filing date
Statement of Dissolution 0004225895 2021-04-02
Annual Report 0004015766 2020-10-01
Annual Report 0003679347 2019-11-18
Amendment to Certificate 0003583270 2019-07-30
Initial Filing 0003304141 2018-10-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344009659 1032500 2019-05-09 2515 EAGLE RD, MERIDIAN, ID, 83642
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2019-05-09
Emphasis L: FALL
Case Closed 2021-01-08

Related Activity

Type Complaint
Activity Nr 1455512
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2019-06-14
Abatement Due Date 2019-06-26
Current Penalty 2000.0
Initial Penalty 3410.0
Final Order 2019-07-24
Nr Instances 5
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Meridian Fire Station multi-pitched 4:12 and 5:12 pitched roof: On or about May 9, 2019 and at times prior thereto; workers were exposed to falls from 8-15 feet onto ground while staging roofing materials and tools, and did not have a fall protection system in place. *Note Abatement certification IS required.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A02
Issuance Date 2019-06-14
Abatement Due Date 2019-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-07-24
Nr Instances 5
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a) Meridian Fire Station multi-pitched roof: On or about May 9, 2019 and at times prior thereto; workers were exposed to falls from 8-15 feet onto ground while staging roofing materials and tools. *Note Abatement certification IS required.

Date of last update: 21 Mar 2025

Sources: Idaho Secretary of State