Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-08-22
|
Emphasis |
N: TRENCH
|
Case Closed |
2025-02-07
|
Related Activity
Type |
Complaint |
Activity Nr |
2203807 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2024-10-30 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
0.0 |
Initial Penalty |
4148.0 |
Final Order |
2024-12-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: a) On August 21, 2024, and at times prior thereto, employees worked in an excavation of type B soil to install a new plumbing service line. The excavation measured between 8 1/2 and 9-feet in depth, 27 - 37 inches wide, and approximately 45 feet long. Employees did not recognize the hazards of working outside of the cave-in protection that was provided and did not recognize that the shoring system was not installed in accordance with the tabulated data. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260651 B02 |
Issuance Date |
2024-10-30 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
0.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-12-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(b)(2): Utility companies or owners were not contacted within established or customary local response times, advised of the proposed work, and asked to establish the location of the utility underground installations prior to the start of an actual excavation. a) On or about August 21, 2024, employees worked in an excavation 45 feet long, 8 ? - 9 feet deep, and 27 - 37 inches wide, in which multiple utilities were present. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2024-10-30 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) On August 21, 2024, and at times prior thereto, employees worked to install new plumbing pipeline in a trench with nearly vertical walls. Hydraulic shoring was not installed in accordance with the tabulated data. The excavation was approximately 8 1/2-9-feet deep with type B soil. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260651 L |
Issuance Date |
2024-10-30 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
1935.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(l): Guardrails complying with 1926.502(b) were not provided where walkways were 6 feet (1.8m) or more above lower levels: (a) On or about August 21, 2024, and at times prior thereto, employees stepped to cross over a trench measuring approximately 8 1/2 to 9 feet deep and 27-37 inches wide. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260652 C02 I |
Issuance Date |
2024-10-30 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
2420.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-12-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: a) On August 21, 2024, and times prior thereto, employees worked in an excavation of type B soil to install a new plumbing service line. The excavation was between 8 1/2 and 9-feet deep, the shoring system was not installed in accordance with the tabulated data. |
|
|