Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-05-16
|
Emphasis |
N: FALL
|
Case Closed |
2024-11-20
|
Related Activity
Type |
Complaint |
Activity Nr |
2163420 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2024-06-20 |
Abatement Due Date |
2024-07-17 |
Current Penalty |
1037.0 |
Initial Penalty |
2074.0 |
Final Order |
2024-08-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On May 16, 2024, an employee used a pneumatic nail gun to install OSB sheathing while wearing sunglasses which did not have the required safety Z87 rating to act as safety glasses. Note: Abatement certification is required for this citation. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-06-20 |
Abatement Due Date |
2024-07-17 |
Current Penalty |
2074.0 |
Initial Penalty |
4148.0 |
Final Order |
2024-08-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m), more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b). a) On May 16, 2024, employees were exposed to fall hazards between 10 feet to 21 feet from the ground below while performing framing activities on a 6:12 sloped roof. Note: Abatement certification is required for this item. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-06-20 |
Current Penalty |
1729.0 |
Initial Penalty |
3457.0 |
Final Order |
2024-08-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On May 16, 2024, employees performing framing activities on a new single-family building were using a ladder which extended approximately 1 foot above the landing to access the roof. This condition exposed employees to fall hazards of 10 feet. Abatement Note: Abatement on-site |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2024-06-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-08-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On May 16, 2024, employees used the top step of an 8-foot A-Frame ladder to get down from a 10 ft roof. Abatement Note: Abatement on-site |
|
|