Search icon

DOUBLE P L.L.C.

Company Details

Name: DOUBLE P L.L.C.
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 01 Oct 2018 (7 years ago)
Financial Date End: 31 Oct 2025
Entity Number: 3303930
Place of Formation: IDAHO
File Number: 636793
ZIP code: 83687
County: Canyon County
Principal Address: 817 LONG VALLEY ST NAMPA, ID 83687-8687
Mailing Address: 42 S ROBINSON BLVD NAMPA, ID 83687-1008

Member

Name Role Address Appointed On
Pedro Prieto Member 817 LONG VALLEY ST, NAMPA, ID 83687 2020-10-15

Agent

Name Role Address
VALLE ACCOUNTING, LLC Agent 5680 E FRANKLIN RD, SUITE 225, NAMPA, ID 83687

Filing

Filing Name Filing Number Filing date
Annual Report Amendment 0005988672 2024-11-19
Annual Report Amendment 0005988693 2024-11-19
Annual Report 0005935122 2024-10-09
Annual Report 0005399442 2023-09-12
Annual Report 0004925764 2022-09-27
Annual Report 0004440124 2021-10-06
Annual Report 0004035381 2020-10-15
Annual Report 0003660298 2019-11-01
Initial Filing 0003303930 2018-10-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347485351 1032500 2024-05-16 3825 N SYCAMORE BLVD, BOISE, ID, 83703
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2024-05-16
Emphasis N: FALL
Case Closed 2024-11-20

Related Activity

Type Complaint
Activity Nr 2163420
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-06-20
Abatement Due Date 2024-07-17
Current Penalty 1037.0
Initial Penalty 2074.0
Final Order 2024-08-05
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On May 16, 2024, an employee used a pneumatic nail gun to install OSB sheathing while wearing sunglasses which did not have the required safety Z87 rating to act as safety glasses. Note: Abatement certification is required for this citation.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-06-20
Abatement Due Date 2024-07-17
Current Penalty 2074.0
Initial Penalty 4148.0
Final Order 2024-08-05
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m), more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b). a) On May 16, 2024, employees were exposed to fall hazards between 10 feet to 21 feet from the ground below while performing framing activities on a 6:12 sloped roof. Note: Abatement certification is required for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-06-20
Current Penalty 1729.0
Initial Penalty 3457.0
Final Order 2024-08-05
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On May 16, 2024, employees performing framing activities on a new single-family building were using a ladder which extended approximately 1 foot above the landing to access the roof. This condition exposed employees to fall hazards of 10 feet. Abatement Note: Abatement on-site
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2024-06-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-05
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On May 16, 2024, employees used the top step of an 8-foot A-Frame ladder to get down from a 10 ft roof. Abatement Note: Abatement on-site

Date of last update: 13 Apr 2025