Search icon

MOLLER CONSTRUCTION

Company Details

Name: MOLLER CONSTRUCTION
Jurisdiction: Idaho
Legal type: Assumed Business Name
Status: Inactive-Cancelled
Date of registration: 08 May 2006 (19 years ago)
Entity Number: 308166
Place of Formation: IDAHO
File Number: 0000308166
ZIP code: 83301
County: Twin Falls County
Mailing Address: 3014 ADDISON AVE E TWIN FALLS, ID 83301

Filing

Filing Name Filing Number Filing date
Cancellation of Certificate of Assumed Business Name 0000848611 2014-03-11
Initial Filing 0000308166 2006-05-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341299154 1032500 2016-03-03 1703 S BUCHANAN ST, JEROME, ID, 83338
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-03-03
Emphasis L: FALL
Case Closed 2016-12-12

Related Activity

Type Complaint
Activity Nr 1068263
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2016-04-18
Abatement Due Date 2016-04-22
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-05-11
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems: a) Darigold Warehouse: On or about March 3, 2016 and at times prior thereto: An employee was observed operating a Varimet welding machine near the leading edge of a 25 foot, low slope roof without the use of a harness or lanyard. Note* Abatement certification is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 H01
Issuance Date 2016-04-18
Abatement Due Date 2016-04-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-05-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(h)(1): The employer did not designate a competent person to monitor the safety of other employees and the employer shall ensure that the safety monitor complies with requirements: a) Darigold warehouse roof: On or about March 3, 2016, and at times prior thereto: An employee was observed operating a welding machine less than six feet from the roof edge and he was not wearing fall protection. A safety monitor was not designated. Abatement certification IS required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260502 F03
Issuance Date 2016-04-18
Abatement Due Date 2016-04-25
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2016-05-11
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(f)(3): Employees were allowed in the area between a roof edge and a warning line except when employee is performing roofing work in that area. a) Darigold warehouse roof: On or about March 3, 2016, and at times prior thereto: An employee was observed operating a welding machine less than six feet from the roof edge and he was not wearing fall protection. Candlestick cones and caution tape were used as the warning line system. Note* Abatement certification IS required for this item.
309963486 1032500 2006-05-10 NORTH ELM VILLAGE CONDOMIUMS, TWIN FALLS, ID, 83301
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2006-05-10
Emphasis L: FALL
Case Closed 2006-11-02

Related Activity

Type Referral
Activity Nr 200243335
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2006-07-28
Abatement Due Date 2006-08-03
Current Penalty 450.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 2
Gravity 03
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2006-07-28
Abatement Due Date 2006-08-09
Nr Instances 1
Gravity 03

Date of last update: 24 Sep 2024