Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-02-25
|
Emphasis |
L: RESCON, L: FALL
|
Case Closed |
2014-06-17
|
Related Activity
Type |
Complaint |
Activity Nr |
873548 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
959932 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-05-02 |
Abatement Due Date |
2014-05-29 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-06-06 |
Nr Instances |
4 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On the east side roof of the southernmost unit of the triplex at 1414 Lone Shore Dr.: on February 25, 2014 and at times prior thereto, employees engaged in finishing an upper-level exterior wall were not protect from falls of approximately 15 feet, to hard packed earth below. (b) On the balcony of the central unit of the triplex at 1414 Lone Shore Dr.: on February 25, 2014 and at times prior thereto, employees engaged interior and exterior construction activities were exposed to falls from approximately 10 feet onto concrete while working on or transiting the balcony. (c) On the roof north of the balcony and above the entrance to central unit of the triplex at 1414 Lone Shore Dr.: on February 25, 2014 and at times prior thereto, employees engaged in exterior construction activities were exposed to falls from approximately 8 feet onto concrete while transiting the roof to access the roof. (d) Second floor, central unit of the triplex at 1414 Lone Shore Dr.: On February 25, 2014 and at times prior thereto, employees engaged interior and exterior construction activities were exposed to falls from approximately 10 feet onto concrete while working near the inadequately guarded stairwell. Note: Abatement certification and documentation are required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 II |
Issuance Date |
2014-05-02 |
Abatement Due Date |
2014-05-29 |
Current Penalty |
1360.0 |
Initial Penalty |
1360.0 |
Final Order |
2014-06-06 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers. (a) On the balcony of the central unit of the triplex at 1414 Lone Shore Dr.: on February 25, 2014 and at times prior thereto, boards used as working surfaces did not completely cover intermediate joists exposing employees to trip/fall hazards. (b) Second floor, top of the stair well in central unit of the triplex at 1414 Lone Shore Dr.: On February 25, 2014 and at times prior thereto, an 8 in. by 36 in. uncovered hole exposed employees to trip/fall hazards. Note: Abatement certification is required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260502 B02 |
Issuance Date |
2014-05-02 |
Abatement Due Date |
2014-05-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-06-06 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high. (a) On the wall opening leading to the balcony of the central unit of the triplex: On February 25, 2014 and at times prior thereto, midrails were not installed on job-made guardrails exposing employees to approximately 10-foot falls on to concrete. (b) Second floor, surrounding the stair well in the central unit of the triplex: On February 25, 2014 and at times prior thereto, midrails were not installed on job-made guardrails exposing employees to approximately 10-foot falls on to concrete. Note: Abatement certification is required for this item. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260502 B07 |
Issuance Date |
2014-05-02 |
Abatement Due Date |
2014-05-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-06-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(7): The ends of all top rails and midrails shall not overhang the terminal posts, except where such overhang does not constitute a projection hazard. (a) Second floor, surrounding the stair well in the central unit of the triplex: On February 25, 2014 and at times prior thereto, job-made guardrails protruded into walkways. Note: Abatement certification is required for this item. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2014-05-02 |
Abatement Due Date |
2014-05-29 |
Current Penalty |
1740.0 |
Initial Penalty |
2040.0 |
Final Order |
2014-06-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) On the balcony of the central unit of the triplex at 1414 Lone Shore Dr.: on February 25, 2014 and at times prior thereto, employees engaged in exterior construction activities accessed the south roof of the structure using a portable stepladder without engaging and locking the spreader. Note: Abatement certification is required for this item. |
|
|