Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-01-13
|
Emphasis |
L: RESCON, L: FALL
|
Case Closed |
2013-12-24
|
Related Activity
Type |
Referral |
Activity Nr |
85003 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2012-01-19 |
Abatement Due Date |
2012-01-20 |
Current Penalty |
1800.0 |
Initial Penalty |
1800.0 |
Final Order |
2012-07-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Jobsite: On January 13, 2012 and times prior thereto employees performed roofing activities on a n approximate six in twelve pitched roof with out a fall protection system in place. Note) Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2012-01-19 |
Abatement Due Date |
2012-01-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-02-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Jobsite: On January 13, 2012 and times prior thereto employee(s) and the responsible person on site did not acknowledge the fall hazard when performing roofing activities and take the necessary actions to minimize the hazard. Note) Abatement certification IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2012-01-19 |
Abatement Due Date |
2012-01-20 |
Current Penalty |
1800.0 |
Initial Penalty |
1800.0 |
Final Order |
2012-07-31 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder: a) Jobsite: On January 13, 2012 employee(s) performing roofing activities were exposed to an approximate ten foot fall hazard when using an extension ladder for access to and from the roof level, which was positioned such that the side rails and top rung of the ladder were below the eave line of the roof. Note) Abatement certification IS required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261060 A01 III |
Issuance Date |
2012-01-19 |
Abatement Due Date |
2012-01-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-02-13 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and stairways had been trained by a competent person in the proper construction, use, placement, and care in handling of all stairways and ladders: a) Jobsite: On January 13, 2012 and times prior thereto, employee(s) and the responsible person on site did not acknowledge the hazard of using a ladder that was not properly positioned and take the appropriate actions to eliminate or minimize the hazard. Note) Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260102 A01 |
Issuance Date |
2012-01-19 |
Abatement Due Date |
2012-01-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-02-13 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) Jobsite: On January 13, 2012 and times prior thereto, an employee performing roofing activities using a pneumatic nail gun did not wear any eye protection. Note) Abatement certification IS required for this item. |
|
|