Search icon

CUSTOM ROTO-MOLDING, INC.

Company Details

Name: CUSTOM ROTO-MOLDING, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Active-Good Standing
Date of registration: 15 Aug 1990 (35 years ago)
Financial Date End: 31 Aug 2025
Entity Number: 288740
Place of Formation: IDAHO
File Number: 288740
Mailing Address: DAVID MAY PO BOX 188 CALDWELL, ID 83606-0188

Agent

Name Role Address
DAVID T. MAY Agent 307 EVANS ST, CALDWELL, ID 83605

President

Name Role Address Appointed On Resigned On
David T May President 3845 N LEGACY COMMON AVE, MERIDIAN, ID 83646 2023-01-09 No data
Raymond A May President 1733 PRAIRIE VIEW WAY, MIDDLETON, ID 83644 2020-10-16 2023-01-09
Ruby May President 307 EVANS ST, CALDWELL, ID 83605 2020-07-06 2020-10-16
Edward B Willson President 1224 DOGWOOD DR, NAMPA, ID 83686 2024-07-03 No data

Secretary

Name Role Address Appointed On
David T May Secretary 3845 N LEGACY COMMON AVE, MERIDIAN, ID 83646 2023-08-03

Director

Name Role Address Appointed On
David T May Director 3845 N LEGACY COMMON AVE, MERIDIAN, ID 83646 2024-07-03

Vice President

Name Role Address Appointed On
David T May Vice President 3845 N LEGACY COMMON AVE, MERIDIAN, ID 83646 2023-08-03

Filing

Filing Name Filing Number Filing date
Annual Report 0005799002 2024-07-03
Annual Report 0005345307 2023-08-03
Articles of Amendment 0005058968 2023-01-09
Annual Report 0004885539 2022-09-06
Annual Report 0004365267 2021-08-03
Annual Report Amendment 0004036444 2020-10-16
Annual Report 0003930977 2020-07-06
Annual Report 0003630496 2019-09-27
Annual Report 0002164934 2018-06-27
Annual Report 0002164933 2017-06-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342813870 1032500 2017-12-06 307 EVANS STREET, CALDWELL, ID, 83605
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-12-06
Emphasis L: FORKLIFT
Case Closed 2018-09-11

Related Activity

Type Complaint
Activity Nr 1288857
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2018-03-22
Abatement Due Date 2018-05-08
Current Penalty 4000.0
Initial Penalty 6467.0
Final Order 2018-04-16
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees; On or about December 6, 2017 and at times prior thereto; operators of a Toyota Hyster Powered Industrial Truck (PIT) were exposed to crushed-by and struck-by hazards while operating a Toyota Hyster without a seatbelt on a public roadway between Building 307, Evans Street and Building 308, Evans Street. Note* Abatement certification IS required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100022 A02
Issuance Date 2018-03-22
Abatement Due Date 2018-08-02
Current Penalty 2600.0
Initial Penalty 5174.0
Final Order 2018-04-16
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(2): (2) The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition: a) Blomquist Building Rotomolding Area: On or about December 6, 2017 and at times prior thereto; Poor drainage and standing water created by the rotomolding cooling process presented slip hazards to employees operating ovens. Note* Abatement certification IS required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100037 A03
Issuance Date 2018-03-22
Abatement Due Date 2018-06-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-16
Nr Instances 2
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Blomquist Building and Trim/Finish Room: On or about December 6, 2017 and at times prior thereto; stacked product i.e. plastic tanks weighing approximately 20-40 pounds each were placed in the exit route. In the event of an emergency, employees navigating around tank product could bump into or trip over product potentially delaying their safe exit out of the building. b) Building 308: On or about December 6, 2017 and at times prior thereto; the exit door on the East wall did not remain open during working hours, had a metal bar across it, and did not have a sign above the door stating it was not an exit. Note* Abatement certification IS required.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100176 A
Issuance Date 2018-03-22
Abatement Due Date 2018-08-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-16
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.176(a): Aisle(s) and passageway(s) were not kept clear and in good repair with no obstruction across or in aisles that could create a hazard. a) Blomquist Building Rotomolding Area: On or about December 6, 2017 and at times prior thereto; push carts and stacked plastic tanks weighing approximately 20-40 pounds each were placed in the aisles and the egress route creating a struck-by hazard and egress hazard. Note* Abatement certification IS required for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2018-03-22
Abatement Due Date 2018-08-02
Current Penalty 4600.0
Initial Penalty 9054.0
Final Order 2018-04-16
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Building 308 Evans Street: On or about December 6, 2017 and at times prior thereto; frayed flexible electrical cords were used to operate the sump pump to minimize wet conditions at the rotomolding oven on the North side of the building. The sump pump is the only means to remove standing water. Note* Abatement certification AND documentation are required for this item.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100305 J01 IV
Issuance Date 2018-03-22
Abatement Due Date 2018-09-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-16
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(j)(1)(iv): Fixtures installed in wet or damp locations were not approved for the purpose and were not so constructed or installed that water could not enter or accumulate in wireways, lamp holders or other electrical parts: a) Building 308 Evans Street: On or about December 6, 2017 and at times prior thereto; electrical boxes used for 110V electrical cords located on the West side of the building were not constructed to prevent water from hoses used to cool molds from rotomolding oven from coming into contact with unprotected electrical components. Note* Abatement certification AND documentation are required for this item.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19100334 A02 I
Issuance Date 2018-03-22
Abatement Due Date 2018-06-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-16
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) Blomquist Rotomolding Production Area: On or about December 6, 2017 and at times prior thereto; a hand-held trim router with a frayed electrical was allowed to operate in an environment with wet floors, exposing employees to potential electric shock hazards. b) Building 308 Evans Street: On or about December 6, 2017 and at times prior thereto; frayed flexible electrical cords were placed on wet concrete and used to operate the sump pump to reduce wet conditions at the rotomolding oven on the North side of the building. Note* Abatement certification AND documentation are required for this item.
Citation ID 01003D
Citaton Type Serious
Standard Cited 19100334 A02 II
Issuance Date 2018-03-22
Abatement Due Date 2018-05-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-16
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) Blomquist Rotomolding Production Area: On or about December 6, 2017 and at times prior thereto; a hand-held trim router with a frayed electrical was allowed to operate in an environment with wet floors, exposing employees to potential electric shock hazards. b) Building 308 Evans Street: On or about December 6, 2017 and at times prior thereto; frayed flexible electrical cords were placed on wet concrete and used to operate the sump pump to reduce wet conditions at the rotomolding oven on the North side of the building. Note* Abatement certification AND documentation are required for this item.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100147 A03 I
Issuance Date 2018-03-22
Abatement Due Date 2018-08-02
Current Penalty 2000.0
Initial Penalty 3879.0
Final Order 2018-04-16
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(a)(3)(i): This employer did not establish a program and utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees. a) Building 308 and Blomquist Building, Rotomolding Production Area: On or about December 2017 and at times prior thereto; maintenance on rotomolding machines was performed without using employer specified procedures for preventing the accidental energization of machines. Note* Abatement certification IS required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4737637107 2020-04-13 1087 PPP 307 Evans Street, CALDWELL, ID, 83605-3928
Loan Status Date 2020-12-19
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 225445
Loan Approval Amount (current) 225445
Undisbursed Amount 0
Franchise Name -
Lender Location ID 56102
Servicing Lender Name KeyBank National Association
Servicing Lender Address 127 Public Sq, CLEVELAND, OH, 44114-1217
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Unanswered
Project Address CALDWELL, CANYON, ID, 83605-3928
Project Congressional District ID-01
Number of Employees 33
NAICS code 423820
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 56102
Originating Lender Name KeyBank National Association
Originating Lender Address CLEVELAND, OH
Gender Male Owned
Veteran Veteran
Forgiveness Amount 226748.26
Forgiveness Paid Date 2020-11-25

Date of last update: 11 Mar 2025

Sources: Idaho Secretary of State