346875685
|
1032500
|
2023-08-01
|
2009 SMEED PARKWAY, CALDWELL, ID, 83605
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-08-01
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2023-12-29
|
Related Activity
Type |
Referral |
Activity Nr |
2060985 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 D02 |
Issuance Date |
2023-11-16 |
Abatement Due Date |
2023-12-13 |
Current Penalty |
7097.0 |
Initial Penalty |
8349.0 |
Final Order |
2023-12-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(2):The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Line #7 Bag Blower: On or about 7/27/2023 and at times prior thereto; employees cleared the discharge of the bag blower that had become jammed while the machine was turned on and operational. |
|
|
344809827
|
1032500
|
2020-06-26
|
2009 SMEED PKWY, CALDWELL, ID, 83605
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-06-26
|
Emphasis |
N: AMPUTATE, N: CHEMNEP
|
Case Closed |
2020-09-24
|
Related Activity
Type |
Complaint |
Activity Nr |
1607562 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II A |
Issuance Date |
2020-08-14 |
Abatement Due Date |
2020-09-10 |
Current Penalty |
10929.0 |
Initial Penalty |
10929.0 |
Final Order |
2020-09-10 |
Nr Instances |
2 |
Nr Exposed |
20 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(A): The energy control procedures did not contain a specific statement on the intended use of the procedure. (a) Production Line 1: On June 26, 2020 and at times prior thereto; the employer did not ensure that lockout/tagout procedures stated when they were to be utilized, such as when servicing and/or maintaining production lines, exposing employees to potential hazardous energies. (b) Production Line 4: On June 26, 2020 and at times prior thereto; the employer did not ensure that lockout/tagout procedures stated when they were to be utilized, such as when clearing jams from the AM Manufacturing Ball Loader, 24-ON Press Loader, #26409, exposing employees to potential hazardous energies. NOTE: Abatement certification AND documentation are required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2020-08-14 |
Abatement Due Date |
2020-09-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-09-10 |
Nr Instances |
2 |
Nr Exposed |
20 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) Production Line 4: On June 26, 2020 and at times prior thereto; the employer did not protect employees in that employees cleared jams from the AM Manufacturing Ball Loader, 24-ON Press Loader, #26409 without controlling potential hazardous energies. (b) Production Line 1: On June 26, 2020 and at times prior thereto; the employer did not protect employees in that employees serviced and/or maintained production lines without controlling potential hazardous energies. NOTE: Abatement certification AND documentation are required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 III B |
Issuance Date |
2020-08-14 |
Abatement Due Date |
2020-09-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-09-10 |
Nr Instances |
1 |
Nr Exposed |
20 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed, or whenever the employer had reason to believe, that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: (a) Production Line 4: On June 26, 2020 and at times prior thereto; the employer did not protect employees in that employees cleared jams from the AM Manufacturing Ball Loader, 24-ON Press Loader, #26409 without controlling potential hazardous energies. NOTE: Abatement certification AND documentation are required for this item. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2020-08-14 |
Abatement Due Date |
2020-09-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-09-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Production Line 4: On May 11, 2020; the employer did not protect employees in that employees cleared jams from the AM Manufacturing Ball Loader, 24-ON Press Loader, #26409 without applying a lockout or tagout device. NOTE: Abatement certification AND documentation are required for this item. |
|
Citation ID |
01001E |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2020-08-14 |
Abatement Due Date |
2020-09-10 |
Current Penalty |
0.0 |
Initial Penalty |
10929.0 |
Final Order |
2020-09-10 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Production Line 4: On June 26, 2020 and at times prior thereto; the employer did not protect employees in that the AM Manufacturing Ball Loader, 24-ON Press Loader, #26409 was not guarded. NOTE: Abatement certification AND documentation are required for this item. |
|
|
343082558
|
1032500
|
2018-04-12
|
11193 WEST EMERALD ST., BOISE, ID, 83707
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-04-12
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2018-04-12
|
Related Activity
Type |
Complaint |
Activity Nr |
1325608 |
Safety |
Yes |
|
|
338912421
|
1032500
|
2013-02-12
|
11193 W EMERALD ST, BOISE, ID, 83713
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-02-13
|
Emphasis |
N: SSTARG11, P: SSTARG11
|
Case Closed |
2013-06-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100134 F02 |
Issuance Date |
2013-04-11 |
Abatement Due Date |
2013-05-07 |
Current Penalty |
0.0 |
Initial Penalty |
2295.0 |
Final Order |
2013-05-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: a.) Dough Stretching: Employees engaged in flour dusting operations, who have been identified as overexposed above the permissible exposure limit for particulates, were required to use half facepiece N95 respirators without being fit tested. Note: Abatement certification is required for this item |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-04-11 |
Abatement Due Date |
2013-05-29 |
Current Penalty |
4500.0 |
Initial Penalty |
6300.0 |
Final Order |
2013-05-02 |
Nr Instances |
3 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip point: a.) Hand Stretch Line: The ingoing nip point at the smasher belt was not equipped with safety barrier guard. Employees were exposed to the hazard of being caught in the ingoing nip point between the belt and the roller. b.) Sealer Area: The ingoing nip point between the smasher belt and the roller was not equipped with a safety barrier guard. Employees were exposed to the hazard of the ingoing nip point. c.) Line No. 10, Boxing Room: The ingoing nip points at the discharge end of the belt conveyor where the belt wraps around the roller were not equipped with safety barrier guard. Note: Abatement certification and documentation are required for this item |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100263 I07 III |
Issuance Date |
2013-04-11 |
Abatement Due Date |
2013-05-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-05-02 |
Nr Instances |
4 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.263(i)(7)(iii): A sufficient number of stop buttons was not provided to enable quick stopping of conveyor(s) where the hazard of getting caught existed: a.) The long belt conveyor at the back end of the Stretch Line was equipped with only one emergency stop at the far east end of the conveyor. Additional emergency stops were not provided to permit ready access to a stopping device in case of emergency. b.) Belt conveyors at press sealer and press diagonal were not equipped with emergency stops. c.) Line No. 10, Boxing Room: The belt conveyor was not equipped with an emergency stop device that can be actuated in an emergency situation to stop the conveyor. d.) Sealer Area Smasher Belt: Emergency stops were not provided and arranged where personnel are normally stationed to stop the conveyors in case of an emergency. Note: Abatement certification and documentation are required for this item |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100263 L03 III A |
Issuance Date |
2013-04-11 |
Abatement Due Date |
2013-05-29 |
Current Penalty |
0.0 |
Initial Penalty |
3825.0 |
Final Order |
2013-05-02 |
Nr Instances |
3 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.263(l)(3)(iii)(a): Main shutoff valves were not located so that explosions, fires, etc. will not prevent access to these valves: a.) Oven No. 10 West, Oven No. 10 East and Oven No. Seven: The main shutoff valves were located above the ovens and accessed only by a portable step ladder. The elevated locations of the shutoff valves were not readily accessible in case of an emergency. Note: Abatement certification is required for this item |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100263 L03 III B |
Issuance Date |
2013-04-11 |
Abatement Due Date |
2013-05-29 |
Current Penalty |
2500.0 |
Initial Penalty |
0.0 |
Final Order |
2013-05-02 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.263(l)(3)(iii)(b): Main shutoff valves were not locked in the closed position when employees entered the oven or when the oven was not in service: a.) Oven No. Eight: The shutoff valve to the natural gas supply-pipe to the oven was not designed to be lockable or capable of being locked out. Thereby employees serviced and maintained the oven without placing a lock on the shutoff valve. Note: Abatement certification is required for this item |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19100263 L09 II |
Issuance Date |
2013-04-11 |
Abatement Due Date |
2013-05-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-05-02 |
Nr Instances |
7 |
Nr Exposed |
150 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.263(l)(9)(ii): All safety devices on the oven(s) were not inspected at intervals of not less than twice a month by a properly instructed bakery employee, and were not inspected at intervals of not less than once a year by a representative of the oven manufacturer: a.) Production Area: The employer did not establish and implement an inspection program for the gas-fired ovens at the facility. Note: Abatement certification is required for this item. |
|
|