345845259
|
1032500
|
2022-03-17
|
11395 W ANNATA ST, NAMPA, ID, 83651
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-03-17
|
Emphasis |
L: FALL
|
Case Closed |
2023-10-12
|
Related Activity
Type |
Referral |
Activity Nr |
1877095 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2022-03-24 |
Abatement Due Date |
2022-04-05 |
Current Penalty |
5221.0 |
Initial Penalty |
5221.0 |
Final Order |
2022-04-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 11395 W Annata St., Nampa, ID 83651: On or about March 17, 2022; employees were exposed to fall hazards of approximately 30 feet while unloading shingles from a suspended load, on a two-story roof with a 5:12 slope. Note - Abatement certification and documentation are required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261417 E01 |
Issuance Date |
2022-03-24 |
Abatement Due Date |
2022-04-05 |
Current Penalty |
5221.0 |
Initial Penalty |
5221.0 |
Final Order |
2022-04-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1417(e)(1):The operator must not leave the controls while the load is suspended: a) 11395 W Annata St., Nampa, ID 83651: On or about March 17, 2022; a crane with a suspended load of shingles on a pallet, was left unattended when the operator went onto the roof to assist in the unloading of the pallet. The load was suspended approximately 30 feet from the ground below and over a residential roof. Note - Abatement certification and documentation are required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261427 A |
Issuance Date |
2022-03-24 |
Abatement Due Date |
2022-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-04-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1427(a): The employer did not ensure that each operator is trained, certified/ licensed, and evaluated in accordance with this section before operating any equipment covered under subpart CC, except for the equipment listed in paragraph (a)(2) of this section. a) 11395 W Annata St., Nampa, ID 83651: On or about March 17, 2022; a crane used to lift roofing materials, including shingles, to the second-floor roof was operated by an employee who had not been trained or licensed to operate cranes. The operator left the crane with a suspended load, and went onto the roof to assist in the unloading of the pallet. Note - Abatement certification and documentation are required for this item. |
|
|
345364830
|
1032500
|
2021-06-15
|
9174 W TANLGEWOOD DRIVE LOT 10 BLOCK 10, BOISE, ID, 83709
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-06-15
|
Emphasis |
L: FALL
|
Case Closed |
2022-08-25
|
Related Activity
Type |
Referral |
Activity Nr |
1777783 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2021-08-19 |
Abatement Due Date |
2021-08-27 |
Current Penalty |
1950.0 |
Initial Penalty |
3901.0 |
Contest Date |
2021-10-08 |
Final Order |
2022-04-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On June 15, 2021 an employee was was exposed to fall hazards of approximately 9 - 19 feet while performing roofing activities on a 6/12 sloped roof. Note - Abatement certification is required for this item. |
|
|
344923271
|
1032500
|
2020-08-27
|
745 SW INBY ST., MOUNTAIN HOME, ID, 83647
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-08-27
|
Emphasis |
L: FALL
|
Case Closed |
2020-08-27
|
Related Activity
Type |
Referral |
Activity Nr |
1658400 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1492308 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1492332 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1492262 |
Safety |
Yes |
|
|
344109020
|
1032500
|
2019-06-24
|
167 WAUSAU ST, MERIDIAN, ID, 83646
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-06-24
|
Emphasis |
L: FALL
|
Case Closed |
2019-06-26
|
Related Activity
Type |
Referral |
Activity Nr |
1469343 |
Safety |
Yes |
|
|
340068188
|
1032500
|
2014-11-05
|
3501 COLE ROAD SIGNATURE POINTE APARTMENTS, BLG B, BOISE, ID, 83706
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-11-05
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2016-10-17
|
Related Activity
Type |
Referral |
Activity Nr |
920145 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-11-24 |
Abatement Due Date |
2014-11-25 |
Current Penalty |
19250.0 |
Initial Penalty |
19250.0 |
Final Order |
2014-12-31 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) On November 5, 2014 employees performing roofing activities on a 6 in 12 and 12 in 12 pitched roof did not have their fall arrest harnesses attached to the fall protection system that was in place. The employees were exposed to a 17 and a half foot fall hazard to a sidewalk or grass. Western Roofing, Inc., was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 106543, citation number 1, item number 2, and was affirmed as a final order on November 7, 2011, with respect to a workplace located at Lot 5, Blk 1 Cabella Creek, Meridian, ID 83680. Western Roofing, Inc., was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 518418, citation number 1, item number 1, and was affirmed as a final order on August 9, 2012, with respect to a workplace located at East Red Rock Street and North Weston Ave, Meridian, ID 83642. Western Roofing, Inc., was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 602299, citation number 1, item number 2, and was affirmed as a final order on December 14, 2012, with respect to a workplace located at 14105 Santa Cruz Street, Caldwell, ID 83607. Note) Certification and documentation of corrective actions ARE required for tis item. |
|
|
339056236
|
1032500
|
2013-05-08
|
9640 PEBBLE BROOK, GARDEN CITY, ID, 83703
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-05-08
|
Emphasis |
L: RESCON, L: FALL
|
Case Closed |
2015-09-30
|
Related Activity
Type |
Complaint |
Activity Nr |
817582 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-06-21 |
Abatement Due Date |
2013-07-18 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2013-08-01 |
Final Order |
2014-06-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system: a) Residential jobsite: On May 8, 2013 and at times prior thereto employees performing re-roofing activities were not protected by the fall protetion system that was in place while installing, removing, relocating and re-installing the anchor points. Note) Abatement certification and documentation ARE required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260502 D17 |
Issuance Date |
2013-06-21 |
Abatement Due Date |
2013-06-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-08-01 |
Final Order |
2014-06-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(17): The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head: a) Residential jobsite: On May 8, 2013 and times prior thereto an employee performing re-roofing activities wore the fall protection harness with the "d-ring" attachment point located at his lower back. Note) Abatement certification IS required for this item. |
|
|
337349211
|
1032500
|
2012-11-07
|
NG ORCHARD TRAINING AREA, BOISE, ID, 83709
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-11-07
|
Emphasis |
N: CTARGET, L: FALL
|
Case Closed |
2013-04-08
|
Related Activity
Type |
Inspection |
Activity Nr |
732823 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
735121 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
734041 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2013-01-07 |
Abatement Due Date |
2013-02-01 |
Current Penalty |
600.0 |
Initial Penalty |
1122.0 |
Final Order |
2013-01-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) New Mess Hall, West roof area: On November 7, 2012, and times prior thereto, employees were working on a 6 inch in 12 inch pitch roof installing metal roofing using rope grabs that were rigged so they would allow a fall of approximately 11 feet and contact with the ground if they fell. Note: Abatement Certification is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2013-01-07 |
Abatement Due Date |
2013-02-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) New Mess Hall roof area: On November 7, 2012, and times prior thereto, employees that were installing new roofing on a 6 inch in 12 inch sloped roof were not trained in the proper use of the rope grab and harness system in that they were not adjusting the slack in the rope grabs to prevent them falling 11 feet and hitting the ground. Note: Abatement Certification is required for this item |
|
|
336574785
|
1032500
|
2012-09-17
|
10334 WEST CULTIS BAY, GARDEN CITY, ID, 83703
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-09-17
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2012-09-17
|
Related Activity
Type |
Referral |
Activity Nr |
582050 |
Safety |
Yes |
|
|
336528583
|
1032500
|
2012-09-13
|
19420 BUSH CREEK AVE, CALDWELL, ID, 83605
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-09-13
|
Emphasis |
L: RESCON, L: FALL
|
Case Closed |
2012-09-13
|
Related Activity
Type |
Referral |
Activity Nr |
577030 |
Safety |
Yes |
|
|
336022991
|
1032500
|
2012-08-29
|
14105 SANTA CRUZ STREET, CALDWELL, ID, 83607
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-29
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2013-02-06
|
Related Activity
Type |
Referral |
Activity Nr |
530290 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19040040 A |
Issuance Date |
2012-11-19 |
Abatement Due Date |
2012-11-30 |
Current Penalty |
660.0 |
Initial Penalty |
880.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
25 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. a) On or about September 10, 2012, the employer failed to provide copies of their injury and illness records for calendar year 2012 to an authorized representative. b) On or about November 16, 2012, the employer failed to provide copies of their injury and illness records for calendar year 2012 to an authorized representative. Western Roofing, Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 313350563, citation number 2, item 1 and was affirmed as a final order on February 25, 2010, with respect to a workplace located at 3801 S. Cole, Boise, ID 83705. Note: Abatement documentation is required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2012-11-19 |
Abatement Due Date |
2012-11-30 |
Current Penalty |
3300.0 |
Initial Penalty |
4400.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On August 29, 2012, an employee was exposed to fall hazards of approximately 18 feet from ground to eave and more than 30 feet from peak to ground on the rake edge while working on the roof of a two-story residence without wearing personal fall arrest equipment. Western Roofing, Inc. was previously cited for violations of this occupational safety and health standard which were contained in: OSHA inspection number 106543, citation number 1, item 2 and was affirmed as a final order on November 7, 2011, with respect to a workplace located at Lot 5, Blk 1, Cabella Creek, Meridian, ID 83680; and OSHA inspection number 518418, citation 1, item 1 and was affirmed as a final order on August 9, 2012, with respect to a workplace located at E. Red Rock Street & N. Weston Ave, Meridian, ID 83642. Note: Abatement documentation is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260102 A02 |
Issuance Date |
2012-11-19 |
Abatement Due Date |
2012-11-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(2): Eye and face protection required by this Part did not meet the requirements specified in American National Standards Institute, Z87.1-1968, Practice for Occupational and Educational Eye and Face Protection: a) On August 29, 2012 and at times prior thereto, an employee was not wearing safety glasses meeting the requirements of the American National Standards Institute standard Z 87.1-1968 while working with pneumatic nail guns. Note: Abatement certification is required for this item. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19261053 B01 |
Issuance Date |
2012-11-19 |
Abatement Due Date |
2012-11-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On August 29, 2012, the side rails of an extension ladders did not extend at least three feet above the roof eave on the front of the house. Note: Abatement certification is required for this item. |
|
|
335184180
|
1032500
|
2012-07-11
|
E. RED ROCK STREET & N. WESTON AVE, MERIDIAN, ID, 83642
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2012-07-13 |
Emphasis |
L: FALL, L: RESCON |
Case Closed |
2012-12-31 |
Related Activity
Type |
Referral |
Activity Nr |
446930 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2012-07-18 |
Current Penalty |
1800.0 |
Initial Penalty |
3080.0 |
Final Order |
2012-08-09 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) Note: If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502. a) West side of structure at 2nd floor offset gable; On or about July 11, 2012 and at times prior thereto, an employee performing dry sheeting on the roof did not have a means of fall protection in place. b) North side of structure, northeast corner of the 1st floor roof; On or about July 11, 2012 and at times prior thereto, an employee performing dry sheeting on the roof did not have a means of fall protection in place. Note: Abatement certification is NOT required for these item. |
|
|
331065433
|
1032500
|
2011-09-17
|
LOT 5 BLK1 CABELLA CREEK, MERIDIAN, ID, 83680
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2011-09-17 |
Emphasis |
L: FALL, L: RESCON |
Case Closed |
2012-10-02 |
Related Activity
Type |
Referral |
Activity Nr |
81056 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2011-10-05 |
Abatement Due Date |
2011-10-06 |
Current Penalty |
842.0 |
Initial Penalty |
1683.0 |
Final Order |
2011-11-07 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.28(a): The employer is responsible for requiring the wearing of appropriate personal protective equipment inall operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazardsto the employees: a) Jobsite: On September 17, 2011 and times prior thereto, the responsible person on site did not require and/or enforce the use of protective eyewear when employees were using powered tools, which included nail guns. Note) Abatement certification IS required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2011-10-05 |
Current Penalty |
1122.0 |
Initial Penalty |
2244.0 |
Final Order |
2011-11-07 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Jobsite: On September 17, 2011 and times prior thereto employees performed roofing activities on an approximate six in twelve pitched roof without the fall protection harnesses that were worn attached to the lanyard and anchorage point that were installed on the roof. b) Jobsite: On September 17, 2011 and times prior thereto an employee performed roofing activities on an approximate ten in twelve pitched roof without a fall protection system in place. Note) Abatement certification IS required for this item. |
|
|
330983412
|
1032500
|
2011-08-31
|
3096 S. BAILEY WAY, MERIDIAN, ID, 83646
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2011-08-31 |
Emphasis |
L: FALL, L: RESCON |
Case Closed |
2011-08-31 |
Related Activity
Type |
Referral |
Activity Nr |
78269 |
Safety |
Yes |
|
|
330017914
|
1032500
|
2011-03-23
|
15715 IDAHO CENTER BLVD, NAMPA, ID, 83651
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2011-03-23 |
Emphasis |
L: FALL, N: CTARGET |
Case Closed |
2012-03-09 |
Related Activity
Type |
Inspection |
Activity Nr |
1789 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 II |
Issuance Date |
2011-04-07 |
Abatement Due Date |
2011-04-28 |
Current Penalty |
765.0 |
Initial Penalty |
1530.0 |
Final Order |
2011-04-25 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were used by employees did not have approved ground fault circuit interrupters for personnel protection: a) Jobsite: On March23 2011, and times prior thereto, employees were using 120 volt generator power from a unit > 5 KW, where there was no assured grounding program in place or GFCIs for electric portable hand-held heat guns. Note: Abatement certification is required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260502 B01 |
Issuance Date |
2011-04-07 |
Current Penalty |
650.0 |
Initial Penalty |
1300.0 |
Final Order |
2011-04-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) Jobsite: On March 23 2011, and times prior thereto, employees were working on the West side of a low slope roof near the edge where the wire rope guard rail was loose and allowed to droop excessively to approximately 35 inches above the walking/working surfaces. Note: Abatement certification is required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260502 B01 |
Issuance Date |
2011-04-07 |
Abatement Due Date |
2011-04-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-04-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) Jobsite: On March 23 2011, and times prior thereto, employees were working on the West side of a low slope roof near the edge where the wire rope guard rail was loose and allowed to droop excessively to approximately 35 inches above the walking/working surfaces. Note: Abatement certification is required for this item. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260502 B09 |
Issuance Date |
2011-04-07 |
Abatement Due Date |
2011-04-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-04-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(9): The employer failed to ensure that wire rope used as a top rail was flagged at 6-foot intervals with high-visibility material: a) West Section of Roof: On March 23, 2011, and times prior thereto, employees were on a roof that had a wire rope guard rail that did not have any flagging. Note: Abatement certification is required for this item |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2011-04-07 |
Abatement Due Date |
2011-04-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-04-25 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used. a) Jobsite: On March 23, 2011 and times prior thereto, employees were not adequately trained to etablish a new fall protection system, in that they did not know the requirement to establish an interim fall protection system when they removed the existing guard rail system from the parapet wall while they installed the final section of roofing over the parapet wall and cap. Note: Abatement certification is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260028 A |
Issuance Date |
2011-04-07 |
Abatement Due Date |
2011-04-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-04-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) Jobsite: On March 23, 2011 and times prior thereto, employees were using Johns Manville TPO membrane cleaner on a rubber roofing material without impervious gloves as recommended by the manufacturer's MSDS. Note: Abatement certification is required for this item. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260152 F03 |
Issuance Date |
2011-04-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-04-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.152(f)(3): Flammable liquids were used where there were open flames or other sources of ignition within 50 feet of the operation: a) Jobsite: On March 23, 2011 and times prior thereto, employees placed a 5 gallon container of a flammable liquid, Johns Manville TPO membrane cleaner, with the cap off on top of a running gas fired electric generator. Note: Abatement certification is required for this item. |
|
|
313355067
|
1032500
|
2010-07-19
|
LOTS 5, 6 & 7, RIVER DISTRICT, EAGLE, ID, 83616
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2010-07-19 |
Emphasis |
L: FALL, S: POWERED IND VEHICLE, S: FALL FROM HEIGHT, L: RESCON, S: STRUCK-BY, S: RESIDENTIAL CONSTR |
Case Closed |
2010-10-19 |
Related Activity
Type |
Referral |
Activity Nr |
200250330 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260100 A |
Issuance Date |
2010-07-22 |
Abatement Due Date |
2010-07-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
313350563
|
1032500
|
2010-01-14
|
3801 S. COLE, BOISE, ID, 83705
|
|
Inspection Type |
Referral |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2010-01-14 |
Emphasis |
S: POWERED IND VEHICLE, S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR, L: FALL |
Case Closed |
2011-03-04 |
Related Activity
Type |
Referral |
Activity Nr |
200249167 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2010-02-17 |
Abatement Due Date |
2010-02-25 |
Current Penalty |
4200.0 |
Initial Penalty |
5600.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2010-02-17 |
Abatement Due Date |
2010-02-25 |
Current Penalty |
4200.0 |
Initial Penalty |
5600.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040040 A |
Issuance Date |
2010-02-17 |
Abatement Due Date |
2010-03-01 |
Initial Penalty |
400.0 |
Nr Instances |
3 |
Nr Exposed |
20 |
Gravity |
01 |
|
|
311578157
|
1032500
|
2008-09-18
|
1130 W. ALLUMBAUGH ST., BOISE, ID, 83706
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2008-09-18 |
Emphasis |
S: FALL FROM HEIGHT, L: FALL |
Case Closed |
2008-09-18 |
|
309969814
|
1032500
|
2007-11-13
|
7751 W. SPECTRUM ST., BOISE, ID, 83709
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2007-11-13 |
Emphasis |
L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT |
Case Closed |
2008-03-31 |
Related Activity
Type |
Referral |
Activity Nr |
200245884 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2008-02-26 |
Abatement Due Date |
2008-03-07 |
Current Penalty |
500.0 |
Initial Penalty |
900.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2008-02-26 |
Abatement Due Date |
2008-03-07 |
Current Penalty |
500.0 |
Initial Penalty |
900.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
02 |
|
|
309971133
|
1032500
|
2007-08-02
|
402 THERMAN MILL, BOISE, ID, 83706
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2007-08-02 |
Emphasis |
L: FALL, L: RESCON, S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT |
Case Closed |
2007-08-06 |
Related Activity
Type |
Referral |
Activity Nr |
200245199 |
Safety |
Yes |
|
|
309970382
|
1032500
|
2007-06-07
|
1415 S. EAGLE RD., MERIDIAN, ID, 83713
|
|
Inspection Type |
Referral |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2007-06-08 |
Emphasis |
L: FALL, S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR, L: IDCONSUB |
Case Closed |
2007-11-14 |
Related Activity
Type |
Referral |
Activity Nr |
200244861 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260502 D21 |
Issuance Date |
2007-07-28 |
Abatement Due Date |
2007-08-23 |
Current Penalty |
1000.0 |
Initial Penalty |
1250.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 B01 |
Issuance Date |
2007-07-28 |
Abatement Due Date |
2007-08-23 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
|
309967891
|
1032500
|
2007-04-02
|
KING'S VIEW SUBDIVISION, CALDWELL, ID, 83606
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2007-04-02 |
Emphasis |
L: FALL, L: RESCON, S: FALL FROM HEIGHT |
Case Closed |
2007-04-13 |
Related Activity
Type |
Referral |
Activity Nr |
200244614 |
Safety |
Yes |
Health |
Yes |
|
|
309965499
|
1032500
|
2006-12-21
|
COLE ROAD AND FAIRVIEW, BOISE, ID, 83704
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2006-12-21 |
Emphasis |
S: COMMERCIAL CONSTR, L: FALL, S: FALL FROM HEIGHT |
Case Closed |
2007-02-13 |
Related Activity
Type |
Referral |
Activity Nr |
200244127 |
Safety |
Yes |
|
|
308336403
|
1032500
|
2004-12-15
|
2120 W. STONEFLY PLACE, NAMPA, ID, 83687
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2004-12-21 |
Emphasis |
L: FALL, L: RESCON |
Case Closed |
2004-12-21 |
Related Activity
Type |
Referral |
Activity Nr |
200240950 |
Safety |
Yes |
Health |
Yes |
|
|
306437799
|
1032500
|
2004-02-02
|
2921 DENALI, BEAR CREEK, MERIDIAN, ID, 83642
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2004-02-02 |
Emphasis |
L: FALL |
Case Closed |
2004-04-29 |
Related Activity
Type |
Referral |
Activity Nr |
200239663 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2004-04-06 |
Abatement Due Date |
2004-04-12 |
Initial Penalty |
6000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
|
306436650
|
1032500
|
2004-01-14
|
278 MAINE AVENUE, NAMPA, ID, 83686
|
|
Inspection Type |
Unprog Rel |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2004-01-14 |
Emphasis |
L: FALL |
Case Closed |
2005-01-07 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2004-04-06 |
Abatement Due Date |
2004-04-12 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Contest Date |
2004-04-28 |
Final Order |
2004-09-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2004-04-06 |
Abatement Due Date |
2004-04-12 |
Current Penalty |
6000.0 |
Initial Penalty |
7500.0 |
Contest Date |
2004-04-28 |
Final Order |
2004-09-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
|
306435645
|
1032500
|
2003-11-06
|
LIBERTY & BETHEL, BOISE, ID, 83706
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2003-11-12 |
Emphasis |
L: FALL |
Case Closed |
2004-01-05 |
Related Activity
Type |
Referral |
Activity Nr |
200238889 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2003-11-25 |
Abatement Due Date |
2003-12-02 |
Current Penalty |
1500.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Repeat |
Standard Cited |
19260503 A02 |
Issuance Date |
2003-11-25 |
Abatement Due Date |
2003-12-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
|
305511834
|
1032500
|
2002-06-18
|
203 LAKE LOWELL AVENUE, NAMPA, ID, 83686
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2002-07-30 |
Emphasis |
S: CONSTRUCTION, L: FALL |
Case Closed |
2002-07-30 |
Related Activity
Type |
Referral |
Activity Nr |
200236602 |
Safety |
Yes |
|
|
305511545
|
1032500
|
2002-06-04
|
16298 JEWEL, CALDWELL, ID, 83607
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2002-06-04 |
Emphasis |
S: CONSTRUCTION |
Case Closed |
2003-05-23 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2002-07-11 |
Abatement Due Date |
2002-07-17 |
Current Penalty |
600.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 |
Issuance Date |
2002-07-11 |
Abatement Due Date |
2002-07-23 |
Current Penalty |
600.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
|
300212370
|
1032500
|
1999-02-05
|
OAKMONT SUBDIVISION LOT 14 BLOCK 4, NAMPA, ID, 83651
|
|
Inspection Type |
Complaint |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1999-02-05 |
Emphasis |
L: FALL, S: CONSTRUCTION |
Case Closed |
1999-03-23 |
Related Activity
Type |
Complaint |
Activity Nr |
76914100 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
1999-02-12 |
Abatement Due Date |
1999-02-19 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
1999-02-12 |
Abatement Due Date |
1999-02-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
1999-02-12 |
Abatement Due Date |
1999-02-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
|
18173260
|
1032500
|
1992-06-09
|
2120 W. STONEFLY PLACE, NAMPA, ID, 83687
|
|
Inspection Type |
Referral |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1992-06-09 |
Case Closed |
1993-09-21 |
Related Activity
Type |
Referral |
Activity Nr |
901194290 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260020 B01 |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
10 |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19260021 B02 |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19260500 G06 I |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
10 |
|
Citation ID |
01002C |
Citaton Type |
Other |
Standard Cited |
19260500 G06 II |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
10 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260059 E01 |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Current Penalty |
250.0 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260059 G01 |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Current Penalty |
250.0 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
01 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260059 H |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Current Penalty |
250.0 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
01 |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19260500 G01 |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-07-21 |
Current Penalty |
2500.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
10 |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19260500 G03 IA |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-07-21 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100020 G01 III |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100020 G02 |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-10-31 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19260252 A |
Issuance Date |
1992-07-15 |
Abatement Due Date |
1992-07-21 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
01 |
|
|