Search icon

DUNSTAN CONSTRUCTION, INC.

Company Details

Name: DUNSTAN CONSTRUCTION, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Active-Good Standing
Date of registration: 22 Jan 1990 (35 years ago)
Financial Date End: 31 Jan 2026
Entity Number: 283467
Place of Formation: IDAHO
File Number: 283467
ZIP code: 83713
County: Ada County
Mailing Address: KYLE DUNSTAN 5310 N BLUE ASH PL BOISE, ID 83713-2018

Agent

Name Role Address
KYLE K. DUNSTAN Agent 5310 N BLUE ASH PL, KYLE DUNSTAN, BOISE, ID 83713-2018

President

Name Role Address Appointed On
Kyle K Dunstan President 5310 N BLUE ASH PL, BOISE, ID 83713 2022-01-09

Filing

Filing Name Filing Number Filing date
Annual Report 0006048021 2025-01-04
Annual Report 0005537861 2024-01-03
Annual Report 0005010945 2022-12-05
Application for Reinstatement 0004559548 2022-01-09
Dissolution/Revocation - Administrative 0003512359 2019-05-15
Annual Report 0002135371 2017-12-11
Annual Report 0002135369 2017-01-20
Annual Report 0002135367 2015-11-19
Annual Report 0002135366 2015-01-21
Annual Report 0002135365 2014-03-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339667149 1032500 2014-04-08 10490 RILEY, BOISE, ID, 83709
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-04-08
Emphasis L: FALL, L: RESCON
Case Closed 2014-06-09

Related Activity

Type Complaint
Activity Nr 879618
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-04-21
Abatement Due Date 2014-04-25
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2014-05-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) Residential jobsite: On April 8, 2014 and at times prior thereto employees performed roofing activities on a 4 in 12 pitched roof without a fall protection system in place. Note) Abatement certification IS required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A02 III
Issuance Date 2014-04-21
Abatement Due Date 2014-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Residential jobsite: On April 8, 2014 and at times prior thereto the employer and the employees did not recognize or acknowledge the potential fall hazards while performing roofing work on a 4 in 12 pitched roof. The employer was not familiar with the acceptable fall protection for this type of work. Note) Abatement certification IS required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-04-21
Abatement Due Date 2014-04-25
Current Penalty 600.0
Initial Penalty 1200.0
Final Order 2014-05-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: a) Residential jobsite: On April 8, 2014 and at times prior thereto employees used an extension ladder for access to and from the roof that did not extend at least three feet above the eave of the roof. Note) Abatement certification IS required for this item.
308344423 1032500 2006-01-12 1706 N. HAMPTON RD., BOISE, ID, 83704
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2006-01-12
Emphasis S: AMPUTATIONS
Case Closed 2006-03-09

Related Activity

Type Inspection
Activity Nr 308344381

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2006-02-02
Abatement Due Date 2006-02-14
Current Penalty 375.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 3
Gravity 03
302581897 1032500 1999-09-08 W ROARING CREEK STREET, MERIDIAN, ID, 83642
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 1999-09-08
Emphasis S: CONSTRUCTION, L: FALL
Case Closed 1999-11-08

Related Activity

Type Referral
Activity Nr 200233252
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 1999-09-14
Abatement Due Date 1999-09-20
Current Penalty 600.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 02
Citation ID 02001
Citaton Type Other
Standard Cited 19260451 C02 V
Issuance Date 1999-09-14
Abatement Due Date 1999-09-20
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 01
Citation ID 02002
Citaton Type Other
Standard Cited 19260454 A
Issuance Date 1999-09-14
Abatement Due Date 1999-10-08
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 01

Date of last update: 03 Apr 2025

Sources: Idaho Secretary of State