Name: | HIGH STANDARD PLASTERING LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Inactive-Dissolved (Administrative) |
Date of registration: | 18 Dec 2009 (15 years ago) |
Financial Date End: | 31 Dec 2012 |
Date dissolved: | 07 Mar 2013 |
Entity Number: | 276980 |
Place of Formation: | IDAHO |
File Number: | 0000276980 |
ZIP code: | 83644 |
County: | Canyon County |
Principal Address: | 705 W CONCORD MIDDLETON, ID 83644 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0002098631 | 2012-02-15 |
Annual Report | 0002098632 | 2011-01-10 |
Initial Filing | 0000276980 | 2009-12-18 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
331065375 | 1032500 | 2011-09-17 | LOT 6 BLK 5, ALPINE POINTE, MERIDIAN, ID, 83642 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 81054 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2011-10-18 |
Abatement Due Date | 2011-10-19 |
Current Penalty | 1200.0 |
Initial Penalty | 2400.0 |
Final Order | 2011-11-15 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Jobsite: On September 17, 2011 and times prior thereto employees performed stucco activities on an estimated eight in twelve pitched roof without a fall protection system in place. Note) Abatement certification IS required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260503 A02 II |
Issuance Date | 2011-10-18 |
Abatement Due Date | 2011-10-19 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2011-11-15 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used: a) Jobsite: On September 17, 2011 and times prior thereto the responsible person and other employees on site were not familiar with the the fall protection requirements when performing stucco activities on a roof area higher than six feet above a lower level, and the actions needed to minimize the hazard. Note) Abatement certification IS required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2011-10-18 |
Abatement Due Date | 2011-10-19 |
Current Penalty | 1200.0 |
Initial Penalty | 2400.0 |
Final Order | 2011-11-15 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Jobsite: On September 17, 2011 and times prior thereto an unsecured extension ladder used by employees for access to the roof to perform stucco activities, was positioned in such a way that the top rung of the ladder was approximately even with the eave of the roof. Note) Abatement certification IS required for this item. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2011-09-13 |
Emphasis | L: FALL |
Case Closed | 2012-01-11 |
Related Activity
Type | Referral |
Activity Nr | 78700 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 G04 I |
Issuance Date | 2011-10-25 |
Abatement Due Date | 2011-11-16 |
Current Penalty | 1500.0 |
Initial Penalty | 3000.0 |
Final Order | 2011-11-15 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: a) Jobsite: On September 13, 2011, and times prior thereto, employees were working on a multi-level scaffold that did not have guardrails installed along all open sides and ends of platforms. Abatement certification is required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260451 H02 II |
Issuance Date | 2011-10-25 |
Abatement Due Date | 2011-11-16 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2011-11-15 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: a) Jobsite: On September 13, 2011, and times prior thereto, employees were working on a scaffold at levels above other employees on lower levels without toeboards to prevent injuries from falling tools or debris. Note: Abatement certification is required for this item. |
Date of last update: 24 Sep 2024