346697204
|
1032500
|
2023-05-11
|
1195 ALPINE AVENUE, CHUBBUCK, ID, 83202
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-05-11
|
Emphasis |
P: FALL, N: FALL, L: FALL
|
Case Closed |
2023-09-01
|
Related Activity
Type |
Inspection |
Activity Nr |
1669736 |
Safety |
Yes |
|
|
344370739
|
1032500
|
2019-10-08
|
30 N MAIN ST., PARIS, ID, 83261
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-10-08
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2020-07-10
|
Related Activity
Type |
Inspection |
Activity Nr |
1437078 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1437094 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260405 A02 II I |
Issuance Date |
2019-11-06 |
Abatement Due Date |
2019-12-04 |
Current Penalty |
1000.0 |
Initial Penalty |
4347.0 |
Final Order |
2019-12-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables were not protected from damage, sharp corners and projections, or pinch points. a) On or about October 8, 2019 and at times prior thereto the General Contractor did not ensure its employees, or its subcontractors protected their employees from electrical hazards where an unprotected temporary flexible cord was routed from a power meter, through a wall, and to a Voltec power distribution box. NOTE-Abatement certification is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260150 C01 I |
Issuance Date |
2019-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-12-04 |
Nr Instances |
1 |
Nr Exposed |
9 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a) On or about October 8, 2019 and at times prior thereto employees and subcontractor employees were constructing a 15,686 square foot building, where only two of the required five fire extinguishers were provided. NOTE- Abatement certification is required for this item. |
|
|
341736650
|
1032500
|
2016-08-25
|
400 S CAPITAL BLVD, BOISE, ID, 83702
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-08-25
|
Emphasis |
L: CRANE, L: FALL, P: SILICA, N: SILICA
|
Case Closed |
2016-08-30
|
|
339850448
|
1032500
|
2014-07-15
|
600 S 1ST WEST, REXBURG, ID, 83460
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-07-15
|
Emphasis |
L: FORKLIFT, N: CTARGET, P: CTARGET
|
Case Closed |
2014-10-31
|
Related Activity
Type |
Inspection |
Activity Nr |
985045 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
985100 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260150 C01 VIII |
Issuance Date |
2014-10-03 |
Abatement Due Date |
2014-10-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-31 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970: a) Various locations throughout the Central Energy Plant: On or about 7-15-2014, fire extinguishers provided by the GC had not been inspected monthly or more frequently, to ensure their condition in case of fire. Note: Abatement certification is required for this item. |
|
|
311579460
|
1032500
|
2008-12-04
|
100 E, JEROME, ID, 83338
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2008-12-04
|
Emphasis |
L: FALL, S: COMMERCIAL CONSTR
|
Case Closed |
2008-12-04
|
|