Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2011-08-05
|
Case Closed |
2013-08-01
|
Related Activity
Type |
Complaint |
Activity Nr |
77050 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2011-12-22 |
Abatement Due Date |
2012-01-17 |
Current Penalty |
900.0 |
Initial Penalty |
1800.0 |
Final Order |
2012-01-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) The compressor mechanical room; on or about August 5, 2011 and at times prior thereto, the gap between the edge of the tool rest and the perimiter of the bench grinding wheel was greater than one eighth inch. Note: Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2011-12-22 |
Abatement Due Date |
2012-01-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-01-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: a) The compressor mechanical room; on or about August 5, 2011 and at times prior thereto, the tongue guard was missing on the side of a Delta Bench Grinder that had an abrasive wheel installed. Note: Abatement certification IS required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 I |
Issuance Date |
2011-12-22 |
Abatement Due Date |
2012-01-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-01-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(1)(i): Horizontal belts which are seven (7) feet or less from the floor level, the guard was not extended to at least fifteen (15) inches above the belt or to a standard height or. that where both runs of a horizontal belt are 42 inches or less from the floor, the belt was not fully enclosed in accordance with paragraphs (m) and (o) of this section: a) The compressor mechanical room; on or about August 5, 2011 and at times prior thereto, three sets of belts and pulleys on the air compressor were not guarded. Note: Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 |
Issuance Date |
2011-12-22 |
Abatement Due Date |
2011-12-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-01-12 |
Nr Instances |
1 |
Nr Exposed |
11 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1): Conductors entering boxes, cabinets, or fittings were not protected from abrasions: (a) In the compressor room; on or about August 5, 2011 and at times prior thereto, a junction box mounted on the wall had an energized conductor entering through the front of the electrical junction box in lieu of entering through the side of the box with an approved fitting. Note: Abatement certification IS required for this item. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 B02 I |
Issuance Date |
2011-12-22 |
Abatement Due Date |
2011-12-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-01-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose: a) In the compressor room; on or about August 5, 2011 and at times prior thereto, a junction box mounted on the wall did not have the cover fully installed leaving the conductors in the box unguarded. Note: Abatement certification IS required for this item. |
|
|