Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-04-18
|
Emphasis |
L: FALL
|
Case Closed |
2024-05-24
|
Related Activity
Type |
Complaint |
Activity Nr |
2019498 |
Safety |
Yes |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
2018568 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 C02 II |
Issuance Date |
2023-08-11 |
Abatement Due Date |
2023-09-07 |
Current Penalty |
0.0 |
Initial Penalty |
14063.0 |
Final Order |
2023-09-13 |
Nr Instances |
1 |
Nr Exposed |
56 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii):The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) On April 18, 2023 and at times prior thereto; employees voluntarily wore North 7700 half-face tight fitting elastomeric respirators while working with chemicals including but not limited to Jet A Fuel, and Methyl ethyl ketone (MEK). Note - Abatement certification and documentation are required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2023-08-11 |
Abatement Due Date |
2023-11-01 |
Current Penalty |
6831.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-13 |
Nr Instances |
1 |
Nr Exposed |
56 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On April 18, 2023 and at times prior thereto; employees voluntarily wore North 7700 half-face tight fitting elastomeric respirators while working with chemicals including but not limited to Jet A Fuel, and Methyl ethyl ketone (MEK). Note - Abatement certification and documentation are required for this item. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100134 K06 |
Issuance Date |
2023-08-11 |
Abatement Due Date |
2023-09-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-13 |
Nr Instances |
1 |
Nr Exposed |
56 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6):The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) On April 18, 2023 and at times prior thereto; employees voluntarily wore North 7700 half-face tight fitting elastomeric respirators while working with chemicals including but not limited to Jet A Fuel, and Methyl ethyl ketone (MEK). Note - Abatement certification and documentation are required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2023-08-11 |
Abatement Due Date |
2023-11-01 |
Current Penalty |
5122.0 |
Initial Penalty |
14063.0 |
Final Order |
2023-09-13 |
Nr Instances |
1 |
Nr Exposed |
56 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) On or about April 18, 2023, employees using chemicals including but not limited to Jet Fuel A and Methyl Ethyl Ketone (MEK) to performing aircraft maintenance effective training in the health hazards of the chemical contents, how they are to protect themselves, and how the employer monitors for hazardous chemicals. Note - Abatement certification and documentation are required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100134 D01 III |
Issuance Date |
2023-08-11 |
Abatement Due Date |
2023-11-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-13 |
Nr Instances |
1 |
Nr Exposed |
56 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: a) On April 18, 2023 and at times prior thereto; employees voluntarily wore North 7700 half-face tight fitting elastomeric respirators while working with chemicals including but not limited to Jet Fuel A. Note - Abatement certification and documentation are required for this item. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100023 B09 |
Issuance Date |
2023-08-11 |
Current Penalty |
500.0 |
Initial Penalty |
1128.0 |
Final Order |
2023-09-13 |
Nr Instances |
1 |
Nr Exposed |
56 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(b)(9): The employer did not ensure that ladders are inspected before initial use in each work shift, and more frequently as necessary, to identify any visible defects that could cause employee injury. a) On or about April 26, 2023, and at times prior, employees were exposed to falls from an elevated position while using a damaged 2 rung step ladder. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100023 B10 |
Issuance Date |
2023-08-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-13 |
Nr Instances |
1 |
Nr Exposed |
65 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(b)(10): The employer did not ensure that any ladder with structural or other defects was immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with � 1910.145 and removed from service until repaired in accordance with � 1910.22(d), or replaced. a) On or about April 26, 2023, and at times prior, employees were exposed to falls from an elevated position while using a damaged 2 rung step ladder. |
|
|