Name: | REED GRAIN & BEAN CO., INC. |
Jurisdiction: | Idaho |
Legal type: | General Business Corporation (D) |
Status: | Active-Good Standing |
Date of registration: | 29 Jul 1985 (40 years ago) |
Financial Date End: | 31 Jul 2025 |
Entity Number: | 247527 |
Place of Formation: | IDAHO |
File Number: | 247527 |
ZIP code: | 83316 |
County: | Twin Falls County |
Mailing Address: | PO BOX 472 BUHL, ID 83316-0472 |
Name | Role | Address |
---|---|---|
EARL W. REED | Agent | 903 ELM, BUHL, ID 83316 |
Name | Role | Address | Appointed On |
---|---|---|---|
EARL REED | President | 4154 N-MEADOW RIDGE CI, TWIN FALLS, ID 83301 | 2020-07-08 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005810497 | 2024-07-08 |
Annual Report | 0005268984 | 2023-06-06 |
Annual Report | 0004851701 | 2022-08-08 |
Annual Report | 0004379337 | 2021-08-11 |
Annual Report | 0003934697 | 2020-07-08 |
Annual Report | 0003545972 | 2019-06-19 |
Annual Report | 0001930830 | 2018-05-23 |
Annual Report | 0001930827 | 2017-05-19 |
Annual Report | 0001930825 | 2016-06-13 |
Annual Report | 0001930823 | 2015-05-22 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340671247 | 1032500 | 2015-05-28 | 903 ELM STREET, BUHL, ID, 83316 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100157 E02 |
Issuance Date | 2015-08-17 |
Abatement Due Date | 2015-09-11 |
Current Penalty | 510.0 |
Initial Penalty | 1020.0 |
Final Order | 2015-09-10 |
Nr Instances | 2 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) Bean Warehouse: On or about 5-28-2015, employees were working in the bean warehouse where the portable fire extinguishers had not received an inspection at least monthly. Note: Abatement certification is required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100157 E03 |
Issuance Date | 2015-08-17 |
Abatement Due Date | 2015-09-11 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-09-10 |
Nr Instances | 2 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check a) Bean Warehouse: On or about 5-28-2015, employees were working in the bean warehouse where the portable fire extinguishers had not received an annual maintenance service since 1-2011. Note: Abatement certification is required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100219 D01 |
Issuance Date | 2015-08-17 |
Abatement Due Date | 2015-09-11 |
Current Penalty | 680.0 |
Initial Penalty | 1360.0 |
Final Order | 2015-09-10 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Mill Shaker/Sorter: On or about 5-28-2015, employees were working near the shaker sorter that had an unguarded drive pulley less than 7 feet from the floor. Note: Abatement certification is required for this item. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2012-08-14 |
Emphasis | L: GRAIN, N: DUSTEXPL |
Case Closed | 2013-08-12 |
Related Activity
Type | Complaint |
Activity Nr | 492573 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100023 A02 |
Issuance Date | 2012-11-08 |
Abatement Due Date | 2012-12-06 |
Current Penalty | 1190.0 |
Initial Penalty | 1360.0 |
Final Order | 2012-12-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.23(a)(2): Ladderway floor opening or platform were not guarded by a standard railing with standard toeboard on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: a) Elevator boot access: On August 14, 2012, and times prior thereto, employees were exposed to a fall hazard of approximately 8 feet from the elevator boot ladder access that was not guarded. Note: Abatement certification is required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100023 A08 |
Issuance Date | 2012-11-08 |
Abatement Due Date | 2012-12-06 |
Current Penalty | 0.0 |
Initial Penalty | 1020.0 |
Final Order | 2012-12-04 |
Nr Instances | 4 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: a) Grain bin stairway: On August 14, 2012, and times prior thereto, employees were exposed to unguarded floor holes in the corner of the stairway landings providing access to the head house. Note: Abatement certification is required for this item. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19100272 J01 |
Issuance Date | 2012-11-08 |
Abatement Due Date | 2012-12-06 |
Current Penalty | 850.0 |
Initial Penalty | 1700.0 |
Final Order | 2012-12-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Variance |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.272(j)(1): The employer did not develop and implement a written housekeeping program that established the frequency and the method(s) determined best to reduce accumulations of fugitive grain dust on ledges, floors, equipment, and other exposed surfaces. a) Grain elevator: On August 14, 2012, and times prior thereto, employees were subjected to explosive fugitive dust that had accumulated on the floor of the head house, because there was no housekeeping program in place. Note: Abatement certification is required for this item. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19100272 J02 II |
Issuance Date | 2012-11-08 |
Abatement Due Date | 2012-12-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-12-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.272(j)(2)(ii): The employer did not immediately remove any fugitive grain dust accumulations whenever the exceeded 1/8 inch (.32cm) at priority housekeeping areas, pursuant to the housekeeping program for grain elevators: a) Grain elevator head house: On August 14, 2012, and times prior thereto, employees were exposed to explosive dust accumulations of approximately 1/2 inch on the floor of the Head House that had not been removed. Note: Abatement certification is required for this item. |
Citation ID | 01003C |
Citaton Type | Serious |
Standard Cited | 19100272 M02 |
Issuance Date | 2012-11-08 |
Abatement Due Date | 2012-12-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-12-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.272(m)(2): The employer did not promptly correct dust collection systems in the grain handling facility which were malfunctioning or operating below designed efficiency: a) Grain Elevator Head House: On August 14, 2012, and times prior thereto, employees were exposed to a build-up of explosive fugitive dust of approximately 1/2 inch in depth caused by the dust collector exhaust fan that had the drive belts taken off of the fan pulleys and was not in operation. Note: Abatement certification is required for this item. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100272 O01 |
Issuance Date | 2012-11-08 |
Abatement Due Date | 2013-03-22 |
Current Penalty | 850.0 |
Initial Penalty | 1700.0 |
Final Order | 2012-12-04 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.272(o)(1): The employer did not provide at least two means of emergency escape from galleries (bin decks) in the grain handling facility: a) Elevator Grain Bin Deck: On August 14, 2012, and times prior thereto, employees were exposed to increased risk from fire and explosions while working in the head house and bin deck because there was only one means of escape provided. Note: Abatement certification is required for this item. |
Date of last update: 02 Apr 2025
Sources: Idaho Secretary of State