Search icon

C WELLS CONSTRUCTION LLC

Company Details

Name: C WELLS CONSTRUCTION LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 20 Dec 2007 (17 years ago)
Financial Date End: 31 Dec 2012
Date dissolved: 07 Mar 2013
Entity Number: 219799
Place of Formation: IDAHO
File Number: 0000219799
ZIP code: 83404
County: Bonneville County
Principal Address: 4212 ROCKINGHAM CIRCLE IDAHO FALLS, ID 83404

Filing

Filing Name Filing Number Filing date
Application for Reinstatement 0000804726 2012-04-09
Annual Report 0001800242 2011-01-10
Annual Report 0001800241 2010-01-10
Annual Report 0001800239 2008-10-13
Initial Filing 0000219799 2007-12-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
330628322 1032500 2011-05-25 PONDEROSA DIV 2, LOT 19, BLK 1, RIGBY, ID, 83442
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2011-05-25
Emphasis L: FALL, L: RESCON
Case Closed 2015-12-03

Related Activity

Type Referral
Activity Nr 47686
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2011-06-08
Abatement Due Date 2011-06-09
Current Penalty 3960.0
Initial Penalty 5280.0
Final Order 2011-06-24
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities six feet or more above a lower level were not protected by guardrail systems, safety net system, or personal fall arrest system: a)Jobsite: On May 25, 2011 and times prior thereto, employee(s) performed framing activities while on the exterior top plate with out a fall protection system in place. b)Jobsite: On May 25, 2011 and times prior thereto, employee(s) performed roof sheathing activities with out a fall protection system in place. Note 1) C. WELLS CONSTRUCTION, LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 311578553, CITATION NUMBER 1, ITEM NUMBER 1, AND WAS AFFIRMED AS A FINAL ORDER ON OCTOBER 24, 2008 WITH RESPECT TO A WORKPLACE LOCATED AT 4846 HAWTHORNE ROAD, CHUBBUCK, ID 83202. Note 2) Abatement certification iIS required for this item.
330292442 1032500 2011-03-08 1871 WARM SPRINGS RD, IDAHO FALLS, ID, 83401
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2011-03-08
Emphasis L: FALL
Case Closed 2015-12-03

Related Activity

Type Referral
Activity Nr 20415
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2011-06-02
Abatement Due Date 2011-06-03
Current Penalty 1200.0
Initial Penalty 2400.0
Final Order 2011-06-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. (a) On or about March 8, 2011, and at times prior thereto, the employer did not provide and/or enforce the use of protective helmets when employees were exposed to overhead hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2011-06-02
Abatement Due Date 2011-06-03
Current Penalty 1200.0
Initial Penalty 2400.0
Final Order 2011-06-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On or about March 8, 2011, and at times prior thereto, employees involved in framing activities were not utilizing protective eye protection when observed utilizing a pneumatic nail gun while sheathing a roof.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2011-06-02
Abatement Due Date 2011-06-03
Current Penalty 3600.0
Initial Penalty 4800.0
Final Order 2011-06-24
Nr Instances 2
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 ft. or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system. (a) On or about March 8, 2011, and at times prior thereto, the employer did not provide and/or enforce the use of fall protection for employees involved in sheathing activities and exposed to fall hazards. (b) On or about March 8, 2011, and at times prior thereto, a hole cut in the floor for the construciton of stairs to the basement level was not protected to prevent employees from tripping, falling and/or stepping into the hole. C. WELLS LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 311578553, CITATION NUMBER 1, ITEM 1, AND WAS AFFIRMED AS A FINAL ORDER ON OCTOBER 24, 2008, WITH RESPECT TO A WORKPLACE LOCATED AT 4846 HAWTHORNE ROAD, CHUBBUCK, ID 83202.
Citation ID 03001
Citaton Type Other
Standard Cited 19261051 A
Issuance Date 2011-05-31
Abatement Due Date 2011-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-06-24
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. (a) Job Site: On or about March 8, 2011, and at times prior thereto, a single 2x4 was utilized as ramp for employees to utilize when entering the residential framed stucture (break in elevation was 24 inches)
311578553 1032500 2008-09-16 4846 HAWTHORNE ROAD, CHUBBUCK, ID, 83202
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2008-09-16
Emphasis S: FALL FROM HEIGHT, S: ELECTRICAL, S: RESIDENTIAL CONSTR, S: POWERED IND VEHICLE, L: FALL
Case Closed 2008-11-05

Related Activity

Type Referral
Activity Nr 200247468
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2008-10-02
Abatement Due Date 2008-10-07
Current Penalty 750.0
Initial Penalty 1500.0
Nr Instances 3
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2008-10-02
Abatement Due Date 2008-10-07
Current Penalty 275.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2008-10-02
Abatement Due Date 2008-10-07
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2008-10-02
Abatement Due Date 2008-10-07
Nr Instances 1
Nr Exposed 1
Gravity 03
Citation ID 02001
Citaton Type Other
Standard Cited 19260403 B02
Issuance Date 2008-10-02
Abatement Due Date 2008-10-07
Nr Instances 1
Nr Exposed 9
Gravity 01

Date of last update: 24 Sep 2024

Sources: Idaho Secretary of State