Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2024-11-06 |
Abatement Due Date |
2024-12-04 |
Current Penalty |
10800.0 |
Initial Penalty |
11292.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. a) Rock Bottom Dairy - Pole Barn: On or about August 15, 2024 and at times prior thereto, employees were exposed to falls from 16 feet to approximately 24.1 feet during installation and material handling of metal roof deck panels. Note* Abatement certification AND supporting documentation of correction are required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260761 B |
Issuance Date |
2024-11-06 |
Abatement Due Date |
2024-12-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761: a) Rock Bottom Dairy - Pole Barn: On or about August 15, 2024 and at times prior thereto; the employer failed to ensure employees engaged in metal roof decking were trained on how to recognize fall hazards and protect themselves from falls. Employees were exposed to 16-24.1 foot falls from a low-sloped roof deck. Note* Abatement certification AND supporting documentation of correction are required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2024-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
8067.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2):The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye. Rock Bottom Dairy: The employer failed to report the hospitalization of an employee who fell from a 24.1 foot pole barn on August, 15 2024. |
|
Citation ID |
02002A |
Citaton Type |
Other |
Standard Cited |
19260405 B01 |
Issuance Date |
2024-11-06 |
Abatement Due Date |
2024-12-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, and fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed: (a) Rock Bottom Dairy Pole Barn: Workers were using a rented SkyJack scissor lift (SJ6826RT 4x4) during metal decking installation activities. The fitting for the flexible cable entering the operator control box was broken/separated. This exposed the individual wires to damage from the opening. NOTE: Certification of corrective action is required for this item. |
|
Citation ID |
02002B |
Citaton Type |
Other |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2024-11-06 |
Abatement Due Date |
2024-12-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) Rock Bottom Dairy Pole Barn: Workers were using a rented SkyJack scissor lift (SJ6826RT 4x4) during metal decking installation activities. The fitting for the flexible cable entering the operator control box was broken/separated. The individual wires applied pull directly to the terminals. NOTE: Certification of corrective action is required for this item. |
|