347232324
|
1032500
|
2023-10-11
|
CITY OF REXBURG, REXBURG, ID, 83440
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2023-10-11
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2023-10-11
|
|
347051831
|
1032500
|
2023-10-11
|
1ST STREET, ID
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2023-10-11
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2023-10-23
|
|
342471356
|
1032500
|
2017-07-13
|
CENTER STREET, REXBURG, ID, 83440
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-07-13
|
Emphasis |
N: TRENCH
|
Case Closed |
2017-07-13
|
Related Activity
Type |
Inspection |
Activity Nr |
1172940 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1247151 |
Safety |
Yes |
|
|
341729408
|
1032500
|
2016-08-03
|
MAIN STREET, REXBURG, ID, 83440
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-08-03
|
Case Closed |
2017-08-29
|
Related Activity
Type |
Referral |
Activity Nr |
1129894 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 E |
Issuance Date |
2016-11-15 |
Abatement Due Date |
2016-12-12 |
Current Penalty |
3200.0 |
Initial Penalty |
6236.0 |
Final Order |
2016-12-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(e): 1926.651(e) Employees were permitted underneath loads handled by lifting or digging equipment. (a) On or about August 3, 2016, and at times prior thereto, the employer did not ensure that employees understood the hazards associated with working underneath lifting and/or digging equipment. Note: Abatement certification IS required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2016-11-15 |
Abatement Due Date |
2016-12-12 |
Current Penalty |
2000.0 |
Initial Penalty |
3741.0 |
Final Order |
2016-12-08 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. Inspections were not conducted by the competent person prior to the start of work and as needed throughout the shift. a) On or about August 3, 2016 and at times prior thereto, the employer did not ensure a "competent person" inspected trenches and excavations prior to the start of work and as needed throughout the shift. Employees were working to install a water line in an excavation at a depth ranging from 4 feet (1.22 m) up to 6.5 feet (1.96 m). Employees did not have the protection of sloping, benching and/or other engineering controls such as an appropriate trench box throughout most of the water line installation and/or have a ladder on the job site for proper ingress/egress. Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260651 C02 |
Issuance Date |
2016-11-15 |
Abatement Due Date |
2016-12-12 |
Current Penalty |
5600.0 |
Initial Penalty |
7483.0 |
Final Order |
2016-12-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Jobsite: On or about August 3, 2016, and at times prior thereto, the employer did not ensure the use of an appropriate ladder and/or other safe means of egress while employees were working to install a water line in a trench at a depth ranging from 4 feet (1.22 m) up to 6.5 feet (1.96 m). Note 1) Abatement certification and documentation ARE required for this item. Note 2) Edstrom Construction, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.651(c)(2), which was contained in OSHA inspection number 63042, citation number 1, item number 1b and was affirmed as a final order on July, 6,2011, with respect to a workplace located at Yellowstone Hwy and 7th South, Rexburg, Idaho 83441. |
|
Citation ID |
02002A |
Citaton Type |
Repeat |
Standard Cited |
19260651 J02 |
Issuance Date |
2016-11-15 |
Abatement Due Date |
2016-12-12 |
Current Penalty |
12471.0 |
Initial Penalty |
7483.0 |
Final Order |
2016-12-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection was not provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) Jobsite: On or about August 3, 2016, an employee performing water line upgrade activities in an approximate 4 feet (1.22 m) up to 6.5 feet (1.96 m), nearly vertical walled excavation was exposed to the hazards of being struck-by falling materials or being caught by a cave-in of the wall and materials where the spoil pile was not placed back at least two feet from the edge of the excavation. Note 1) Edstrom Construction, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.651(j)(2), which was contained in OSHA inspection number 63042, citation number 2, item number 2 and was affirmed as a final order on July, 6,2011, with respect to a workplace located at Yellowstone Hwy and 7th South, Rexburg, Idaho 83441. Note 2) Abatement certification and documentation ARE required for this item. |
|
Citation ID |
02002B |
Citaton Type |
Repeat |
Standard Cited |
19260652 A01 |
Issuance Date |
2016-11-15 |
Abatement Due Date |
2016-12-12 |
Current Penalty |
0.0 |
Initial Penalty |
12471.0 |
Final Order |
2016-12-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) On or about August 2, 2016 and at times prior thereto, the employer did not protect each worker by properly sloping the sides and/or using appropriate protective systems such as a trench box. Employees were working to install a water line in a trench at a depth ranging from 4 feet (1.22 m) up to 6.5 feet (1.96 m) with nearly vertical walls. Note 1) Edstrom Construction, Inc. was previously cited for a violation of this Occupational Safety and Health Standard which was contained in OSHA inspection number 311576409, citation number 1, item number 3, and was affirmed as a final order on June 20, 20008 with respect to the workplace at Main Street and Highway 20 East, Sugar City, ID 83448. Note 2) Abatement certification and documentation ARE required for this item. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19260652 C03 III |
Issuance Date |
2016-11-15 |
Abatement Due Date |
2016-12-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-12-08 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(c)(3)(iii): At least one copy of the tabulated data, which identifies the registered professional engineer who approved the data, was not maintained at the jobsite during construction of the protective system: (a) On or about August 3, 2016, and at times prior thereto, the tabulated data was not available at the jobsite. Note: Abatement certification IS required for this item. |
|
|
330630427
|
1032500
|
2011-05-25
|
YELLOWSTONE HWY AND 7TH SOUTH, REXBURG, ID, 83441
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-05-25
|
Emphasis |
N: TRENCH
|
Case Closed |
2013-06-12
|
Related Activity
Type |
Referral |
Activity Nr |
47805 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2011-06-17 |
Current Penalty |
2805.0 |
Initial Penalty |
5390.0 |
Final Order |
2011-07-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to an employee in that the employee was exposed to falling, crushing, and caught-in hazards when being lowered into a trench in the bucket of an excavator: a) Jobsite: On May 25, 2011 the bucket of a Volvo 235 excavator was used to lower an employee into an unprotected area of an approximate 19 foot deep, nearly vertical walled excavation to perform sewer line installation activities. This exposed the employee to the hazards of falling approximately 19 feet, to being struck by the bucket, and being caught in-between moving parts of the excavator bucket. Note 1) Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow SAE J153, Surface Vehicle Recommended Practice, Section 4.3 Operator-General Precautions, instructs operators: "Do not permit riders on the machine if there is no manufacturer's designated place for a rider." Note 2) Abatement certification and documentation are NOT required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
2011-06-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-07-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Jobsite: On May 25, 2011 a ladder was not in place to provide an employee working in an approximate 19 foot deep excavation, a safe means to enter or egress the excavation. Note) Abatement certification and documentation are NOT required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260652 G01 III |
Issuance Date |
2011-06-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-07-06 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(g)(1)(iii): Employees were not protected from the hazard of cave-ins when entering or exiting the areas protected by shields: a) Jobsite: On May 25, 2011 an employee was lowered into the excavation in the bucket of an excavator, to an area outside of the protective shields that were in place. The excavation was approximately 19 feet deep, and nearly vertical walled. Note) Abatement and certification documentation are NOT required for this item. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2011-06-17 |
Abatement Due Date |
2011-06-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-07-06 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) Jobsite: On May 25, 2011 an extension ladder that was hung on brackets inside of the trench box during the inspection, which allowed an employee to egress the excavation, was positioned at a 90 degree angle. Note) Abatement certification and documentation ARE required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260651 J02 |
Issuance Date |
2011-06-17 |
Abatement Due Date |
2011-06-20 |
Current Penalty |
5395.0 |
Initial Penalty |
6160.0 |
Final Order |
2011-07-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection was not provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) Jobsite: On May 25, 2011 an employee performing sewer installation activities in an approximate 19 foot deep, nearly vertical walled excavation was exposed to the hazards of being struck-by falling materials or being caught by a cave-in of the wall and materials where the spoil pile was not placed back at least two feet from the edge of the excavation. Note 1) Edstrom Construction, Inc was previously cited for a violation of this Occupational Safety and Health Standard which was contained in OSHA inspection number 311576409, citation number 1, item number 3, and was affirmed as a final order on June 20, 20008 with respect to the workplace at Main Street and Highway 20 East, Sugar City, ID 83448. Note 2) Abatement certification and documentation ARE required for this item. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260652 A01 |
Issuance Date |
2011-06-17 |
Current Penalty |
5000.0 |
Initial Penalty |
7700.0 |
Final Order |
2011-07-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) Jobsite: On May 25, 2011 an employee in an approximate 19 foot deep excavation, worked outside of the area protected by a trench box. b) Jobsite: On May 25, 2011 the open end of the trench box being used was within several feet of the approximate 19 foot deep excavated wall. Note) Edstrom Construction, Inc was previously cited for a violation of this Occupational Safety and Health Standard which was contained in OSHA inspection number 311576409, citation number 1, item number 4b and was affirmed as a final order on June 20, 2008, with respect to the workplace at Main Street and Highway 20 East, Sugar City, ID 83448. |
|
|
330293770
|
1032500
|
2011-04-28
|
PIONEER ROAD & 7TH SOUTH, REXBURG, ID, 83440
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-04-28
|
Emphasis |
N: TRENCH
|
Case Closed |
2012-01-18
|
Related Activity
Type |
Referral |
Activity Nr |
20672 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260652 G02 |
Issuance Date |
2011-05-09 |
Abatement Due Date |
2011-05-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-06-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(g)(2): Excavations of earth material to a level greater than 2 feet (.61m) below the bottom of a shield was permitted: a) East end of excavation; On or about 4/28/11 and at times prior thereto, an employee was working to spread/compact backfill over a section of PVC sewer pipe in an excavation that was approximately 20 feet deep. The trench shield that the employee was working in was installed approximately 4 feet above the bottom of the excavation. Note: Abatement certification IS required for this item. |
|
|
311581268
|
1032500
|
2009-02-25
|
1200 WEST UNIVERSITY BLVD, REXBURG, ID, 83440
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-03-05
|
Emphasis |
S: COMMERCIAL CONSTR, N: TRENCH
|
Case Closed |
2009-03-05
|
|
311576409
|
1032500
|
2008-05-15
|
MAIN STREET & HIGHWAY 20 EAST, SUGAR CITY, ID, 83448
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2008-05-15
|
Emphasis |
S: COMMERCIAL CONSTR, S: POWERED IND VEHICLE, S: TRENCHING, N: TRENCH
|
Case Closed |
2009-01-15
|
Related Activity
Type |
Referral |
Activity Nr |
200246825 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260303 D |
Issuance Date |
2008-06-06 |
Abatement Due Date |
2008-06-12 |
Current Penalty |
450.0 |
Initial Penalty |
900.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 E |
Issuance Date |
2008-06-06 |
Abatement Due Date |
2008-06-12 |
Current Penalty |
800.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
2008-06-06 |
Abatement Due Date |
2008-06-12 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2008-06-06 |
Abatement Due Date |
2008-06-12 |
Current Penalty |
2350.0 |
Initial Penalty |
4200.0 |
Nr Instances |
2 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2008-06-06 |
Abatement Due Date |
2008-06-12 |
Nr Instances |
3 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01004C |
Citaton Type |
Serious |
Standard Cited |
19260652 G01 III |
Issuance Date |
2008-06-06 |
Abatement Due Date |
2008-06-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19260652 C03 III |
Issuance Date |
2008-06-06 |
Abatement Due Date |
2008-06-12 |
Current Penalty |
800.0 |
Initial Penalty |
1500.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19260652 D03 |
Issuance Date |
2008-06-06 |
Abatement Due Date |
2008-06-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
|
308344019
|
1032500
|
2006-01-05
|
320 HILAND, BURLEY, ID, 83318
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2006-01-05
|
Emphasis |
N: TRENCH
|
Case Closed |
2006-04-18
|
Related Activity
Type |
Inspection |
Activity Nr |
308343953 |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19100134 D01 III |
Issuance Date |
2006-01-11 |
Abatement Due Date |
2006-01-24 |
Initial Penalty |
1500.0 |
Nr Instances |
34 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19260021 B06 I |
Issuance Date |
2006-01-11 |
Abatement Due Date |
2006-01-24 |
Nr Instances |
34 |
Gravity |
01 |
|
|
308339977
|
1032500
|
2005-07-13
|
WASTEWATER TREATMENT PLANT, ST ANTHONY, ID, 83445
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-07-13
|
Case Closed |
2005-09-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2005-08-25 |
Abatement Due Date |
2005-09-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
2005-08-25 |
Abatement Due Date |
2005-09-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 II |
Issuance Date |
2005-08-25 |
Abatement Due Date |
2005-09-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19101200 G01 |
Issuance Date |
2005-08-25 |
Abatement Due Date |
2005-09-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
308337138
|
1032500
|
2005-01-27
|
OFF HIGHWAY 33, VICTOR, ID, 83455
|
|
Inspection Type |
Planned |
Scope |
NoInspection |
Safety/Health |
Safety |
Case Closed |
2005-02-04 |
|
306438417
|
1032500
|
2004-05-06
|
OFF HWY 33 ( S. BASELINE RD), VICTOR, ID, 83455
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2004-05-06 |
Emphasis |
N: TRENCH |
Case Closed |
2004-05-10 |
|
306438466
|
1032500
|
2004-05-06
|
100 WEST, VICTOR, ID, 83455
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2004-05-06 |
Emphasis |
N: TRENCH |
Case Closed |
2004-09-17 |
Related Activity
Type |
Referral |
Activity Nr |
200239887 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
2004-06-14 |
Abatement Due Date |
2004-07-01 |
Current Penalty |
300.0 |
Initial Penalty |
375.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
2004-06-14 |
Abatement Due Date |
2004-07-01 |
Current Penalty |
300.0 |
Initial Penalty |
375.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2004-06-14 |
Abatement Due Date |
2004-07-01 |
Current Penalty |
300.0 |
Initial Penalty |
375.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
|
306434580
|
1032500
|
2003-09-17
|
ANDREWS ADDITION DIVISION #2, REXBURG, ID, 83440
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2003-09-17 |
Emphasis |
N: TRENCH |
Case Closed |
2003-11-03 |
Related Activity
Type |
Referral |
Activity Nr |
200238665 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260602 A09 I |
Issuance Date |
2003-10-14 |
Abatement Due Date |
2003-10-24 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260651 K01 |
Issuance Date |
2003-10-14 |
Abatement Due Date |
2003-10-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260652 B01 II |
Issuance Date |
2003-10-14 |
Abatement Due Date |
2003-10-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
01 |
|
|
305511404
|
1032500
|
2002-05-23
|
BYU IDAHO CAMPUS, REXBURG, ID, 83440
|
|
Inspection Type |
Unprog Rel |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2002-05-23 |
Emphasis |
N: TRENCH, S: CONSTRUCTION |
Case Closed |
2002-06-12 |
Related Activity
Type |
Referral |
Activity Nr |
200236479 |
Safety |
Yes |
|
|
302580857
|
1032500
|
1999-07-08
|
TEAL AND EAGLE RIDGE ROADS, VICTOR, ID, 83455
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1999-07-08 |
Emphasis |
N: TRENCH, S: CONSTRUCTION |
Case Closed |
2004-06-23 |
Related Activity
Type |
Referral |
Activity Nr |
200233138 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260651 K02 |
Issuance Date |
1999-07-15 |
Abatement Due Date |
1999-07-21 |
Current Penalty |
3000.0 |
Initial Penalty |
4000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19260652 A01 |
Issuance Date |
1999-07-14 |
Abatement Due Date |
1999-07-20 |
Current Penalty |
3000.0 |
Initial Penalty |
4000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
|
302580840
|
1032500
|
1999-07-08
|
BETWEEN DRIGGS AND VICTOR, DRIGGS, ID, 83422
|
|
Inspection Type |
Planned |
Scope |
NoInspection |
Safety/Health |
Safety |
Close Conference |
1999-07-08 |
Emphasis |
S: CONSTRUCTION |
Case Closed |
1999-07-08 |
|
300211570
|
1032500
|
1998-11-20
|
N. CENTER JUST NORTH OF MAIN STREET, REXBURG, ID, 83440
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1998-11-20 |
Emphasis |
N: TRENCH |
Case Closed |
2001-06-13 |
Related Activity
Type |
Referral |
Activity Nr |
74603721 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
1999-01-15 |
Abatement Due Date |
1999-01-22 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
1999-01-15 |
Abatement Due Date |
1999-01-22 |
Current Penalty |
500.0 |
Initial Penalty |
1050.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260651 K02 |
Issuance Date |
1999-01-15 |
Abatement Due Date |
1999-01-22 |
Current Penalty |
775.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
1999-01-15 |
Abatement Due Date |
1999-01-22 |
Current Penalty |
775.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
|
107239790
|
1032500
|
1994-08-03
|
MAIN STREET, FIRTH, ID, 83236
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1994-08-03 |
Emphasis |
N: TRENCH |
Case Closed |
1996-12-02 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
1994-09-29 |
Abatement Due Date |
1994-10-03 |
Current Penalty |
300.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260602 A09 II |
Issuance Date |
1994-09-29 |
Abatement Due Date |
1994-10-07 |
Current Penalty |
300.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260651 H01 |
Issuance Date |
1994-09-29 |
Abatement Due Date |
1994-10-04 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
1994-09-29 |
Abatement Due Date |
1994-10-04 |
Current Penalty |
300.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260652 A01 |
Issuance Date |
1994-09-29 |
Abatement Due Date |
1994-10-03 |
Current Penalty |
4500.0 |
Initial Penalty |
6000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19260600 A05 |
Issuance Date |
1994-09-29 |
Abatement Due Date |
1994-10-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
107237877
|
1032500
|
1994-04-13
|
NEAR 1ST STREET & FARNSWORTH, IDAHO FALLS, ID, 83401
|
|
Inspection Type |
Referral |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1994-04-13 |
Emphasis |
N: TRENCH |
Case Closed |
1995-09-01 |
Related Activity
Type |
Referral |
Activity Nr |
901723742 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260020 B01 |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-06-24 |
Current Penalty |
225.0 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-06-24 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260059 E01 |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-06-24 |
Current Penalty |
225.0 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260059 G08 |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-06-24 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19260059 H |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-06-24 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-05-13 |
Current Penalty |
525.0 |
Initial Penalty |
1050.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-06-02 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-05-13 |
Current Penalty |
800.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260652 C |
Issuance Date |
1994-05-09 |
Abatement Due Date |
1994-05-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|