Search icon

TRIMCO MILLWORK

Company Details

Name: TRIMCO MILLWORK
Jurisdiction: Idaho
Legal type: Assumed Business Name
Status: Active-Current
Date of registration: 08 May 2003 (22 years ago)
Entity Number: 206647
Place of Formation: IDAHO
File Number: 0000206647
ZIP code: 83642
County: Ada County
Mailing Address: 280 E CORPORATE DR #200 MERIDIAN, ID 83642

Filing

Filing Name Filing Number Filing date
Initial Filing 0000206647 2003-05-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334089232 1032500 2012-05-01 1835 COMMERCE AVE, BOISE, ID, 83715
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-05-01
Emphasis N: SSTARG11
Case Closed 2012-12-13

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100132 E
Issuance Date 2012-09-21
Abatement Due Date 2012-09-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-10-19
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(e): The employer did not ensure that employees were not using defective or damaged personal protective equipment in the workplace: a) Door Shop Area: On or about May 1, 2012 and at times prior thereto, employees were using a lanyard attached to a Hyster R30C oder picker with a carabiner that was damaged and did not latch properly. Note: Abatement certification is required for this item
Citation ID 01002
Citaton Type Other
Standard Cited 19100157 E03
Issuance Date 2012-09-21
Abatement Due Date 2012-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-10-19
Nr Instances 3
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) Throughout the facility: On or about May 1, 2012 and at time prior thereto, portable fire extinguishers had not been annually inspected since June of 2009. Note: Applies to any extinguishers provided in the workplace. Maintenance check includes an internal examination, except extinguishers with stored pressure.
Citation ID 01003
Citaton Type Other
Standard Cited 19100176 B
Issuance Date 2012-09-21
Abatement Due Date 2012-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-10-19
Nr Instances 2
Nr Exposed 15
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) Door shop & Millwork warehouse: On or about May 1, 2012 and at times prior thereto, racks used for storage that are accessed by fork lifts and order pickers were not securely bolted to the floor. Note: Abatement certification is required for this item
Citation ID 01004
Citaton Type Other
Standard Cited 19100178 L02 II
Issuance Date 2012-09-21
Abatement Due Date 2012-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-10-19
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) Door shop: On or about May 1, 2012 and at times prior thereto an employee whose job encompassed driving a powered industrial truck had not had pratctical training to ensure proper powered industrial truck operation. b) Millwork warehouse: On or about May 1, 2012 and at times prior thereto an employee whose job encompassed driving a powered industrial truck had not had formal instruction to ensure proper knowledge of powered industrial truck operation. Note: Abatement certification is required for this item.
Citation ID 01005
Citaton Type Other
Standard Cited 19100213 H04
Issuance Date 2012-09-21
Abatement Due Date 2012-10-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-10-19
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: a) Door shop: On or about May 1, 2012 and at times prior thereto: A Delta 10 inch Professional Radial Saw, No. 424-02-131-0014 being used to cut trim did not self retract when released by operator. Note: Abatement certification is required for this item.
Citation ID 01006
Citaton Type Other
Standard Cited 19100303 B02
Issuance Date 2012-09-21
Abatement Due Date 2012-09-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-10-19
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Door Shop: On or about May 1, 2012 and at times prior thereto, a relocatable power tab was permanently mounted to a wall and used for equipment such as a router and radial arm saw. Note: Abatement certification is required for this item.
Citation ID 01007
Citaton Type Other
Standard Cited 19100305 B01 II
Issuance Date 2012-09-21
Abatement Due Date 2012-09-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-10-19
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Millwork warehouse: On or about May 1, 2012 and at times prior thereto an electrical circuit breaker box was missing a knockout cover. Note: Abatement certification is required for this item.
Citation ID 01008
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2012-09-21
Abatement Due Date 2012-09-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-10-19
Nr Instances 2
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Door shop: On or about May 1, 2012 and at times prior thereto a 3-way extension cord was used to permanently power a chop saw and two routers. b) Millwork warehouse: On or about May 1, 2012 and at times prior thereto an extension cord was used to permanently power a Hitachi C12LSH chop saw. Note: Abatement certification is required for this item.