347593642
|
1032500
|
2024-07-02
|
4751 USTICK RD., NAMPA, ID, 83687
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-07-02
|
Emphasis |
N: CTARGET, N: HEATNEP, P: CTARGET
|
Case Closed |
2024-09-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1759355 |
Health |
Yes |
|
|
347126955
|
1032500
|
2023-11-24
|
650 MIDLAND BLVD, ID
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2023-11-24
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2023-11-24
|
|
346962442
|
1032500
|
2023-09-07
|
1653 STATE ST, EAGLE, ID, 83616
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-09-07
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2024-03-08
|
Related Activity
Type |
Inspection |
Activity Nr |
1696255 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1696268 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1696272 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1696264 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1696260 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-23 |
Current Penalty |
3000.0 |
Initial Penalty |
6026.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2):Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) On September 7th, 2023 and times prior to, the controlling employer did not ensure that its sub-contractor employees were protected from electrical shock, as extension cords used to provide power from a junction box to multiple parts of the property were connected in a series and spanned an approximate total distance of 700 feet. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 II I |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(I):Flexible cords and cables used for temporary wiring were not protected from damage: (a) On September 7th, 2023 and times prior to, the controlling employer did not ensure that its sub-contractor employees were protected from electrical shock, as an extension cord was run through a hole cut in an aluminum wall. The hole was not protected and had multiple sharp portions that could damage the cords insulation. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260416 E02 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(2):Extension cords were fastened with staples, hung from nails, or suspended by wire: (a) On September 7th, 2023 and times prior, he controlling employer did not ensure that its sub-contractor employees were protected as multiple extension cords were suspended by rope from the adjacent building in order to run power to different portions of the property. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-16 |
Current Penalty |
8000.0 |
Initial Penalty |
12055.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a): On September 7th, 2023 and times prior, the employer did not ensure that its sub-contractor protected its employees from falls while applying stucco from the second level of the scaffolding. Multiple scaffolding platforms only had two of the required 4 planks. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i):Guardrail systems were not installed along all open sides and ends of platforms. (a): On September 7th, 2023 and times prior, the controlling employer did not ensure that its sub-contractor employees were protected from falls while working on scaffolding that did not have guardrails on open sides, leading to potential falls of 13.5 feet. Abatement Note: Abatement certification and documentation is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-23 |
Current Penalty |
8000.0 |
Initial Penalty |
12055.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a): On September 7th, 2023 and times prior, the controlling employer did not ensure that its sub-contractor employees were protected from falls while accessing scaffolding platforms. Employees used cross braces for access and egress purposes. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260451 E09 IV |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(9)(iv):Cross braces on tubular welded frame scaffolds were used as a means of access or egress. (a) On September 7th, 2023 and times prior, the employer did not ensure that its subcontractor protected its employees from falls while accessing the lower and upper levels of scaffolding. Employees used the frames of the scaffold. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 H02 II |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
3000.0 |
Initial Penalty |
6026.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: (a) On September 7th, 2023 and times prior, the controlling employer did not ensure that its sub-contractor protected employees working below the scaffold from falling materials such as a bucket with stucco and application tools. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-16 |
Current Penalty |
8000.0 |
Initial Penalty |
12055.0 |
Final Order |
2024-02-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2):Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: (a) On September 7th, 2023 and times prior, the employer did not ensure that its sub-contractor protected its employees while applying stucco from the second and first level of a scaffold. Bracing was missing in several areas throughout the scaffold. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
|
345946230
|
1032500
|
2022-05-05
|
119 S HIGHWAY 24, RUPERT, ID, 83350
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-05-05
|
Emphasis |
L: FALL
|
Case Closed |
2022-09-01
|
Related Activity
Type |
Referral |
Activity Nr |
1891229 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260760 D01 |
Issuance Date |
2022-06-24 |
Abatement Due Date |
2022-07-21 |
Current Penalty |
6092.0 |
Initial Penalty |
8702.0 |
Final Order |
2022-08-04 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(d)(1): Guardrail systems, safety net systems, personal fall arrest systems, positioning device systems and their components did not conform to the criteria in �� 1926.502 (Appendix G to this subpart). (a) On or about May 5, 2022, and at times thereto, employees engaged in steel erection activities working to install metal roof decking were exposed to an approximate 17 foot fall hazard. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260761 B |
Issuance Date |
2022-06-24 |
Abatement Due Date |
2022-07-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-08-04 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.761(b):The employer did not train each employee exposed to a fall hazard in accordance with the requirements of this section. (a) On or about May 5, 2022, and at times thereto, employees engaged in steel erection activities working to install metal roof decking were exposed to an approximate 17 foot fall hazard. Employees were not provided with adequate knowledge to identify fall hazards in the work area and the procedures to be followed to prevent falls to lower levels while performing this work. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2022-06-24 |
Abatement Due Date |
2022-07-21 |
Current Penalty |
17403.0 |
Initial Penalty |
17403.0 |
Final Order |
2022-08-04 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Each employee engaged in steel erection activity who is on a walking/ working surface with an unprotected side or edge was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems. (a) On or about May 5, 2022, and at times thereto, employees engaged in steel erection activities working to install metal roof decking were exposed to an approximate 17 foot fall hazard. Forge Building Company, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.760(a)(1), which was contained in OSHA inspection number 1566875, citation number 1, item number 1b and was affirmed as a final order on 2/15/2022, with respect to a workplace located at 7373 S. Federal Way, Boise, ID 83716. |
|
|
345921555
|
1032500
|
2022-04-21
|
2695 ADDISON AVE, TWIN FALLS, ID, 83301
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-04-21
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2022-04-21
|
Related Activity
Type |
Inspection |
Activity Nr |
1592167 |
Safety |
Yes |
|
|
345794838
|
1032500
|
2022-02-18
|
3000 S WISE WAY, BOISE, ID, 83716
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2022-02-18
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2022-02-18
|
|
345782387
|
1032500
|
2022-02-10
|
1291 LATITUDE CIR, TWIN FALLS, ID, 83301
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-02-10
|
Emphasis |
L: FALL, N: CTARGET, P: CTARGET
|
Case Closed |
2022-05-04
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2022-02-25 |
Current Penalty |
3915.8 |
Initial Penalty |
5594.0 |
Final Order |
2022-03-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn/attached by employee(s) when working from an aerial lift. (a) On or about February 10, 2022, and at times prior thereto, two employees had donned Personal Fall Arrest System (PFAS) but failed to attach their lanyards to the Genie aerial lift. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e). |
|
|
345668750
|
1032500
|
2021-12-02
|
7373 S FEDERAL WAY, BOISE, ID, 83716
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-12-02
|
Emphasis |
L: FALL
|
Case Closed |
2022-03-22
|
Related Activity
Type |
Referral |
Activity Nr |
1839539 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1566876 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2022-01-27 |
Abatement Due Date |
2022-02-08 |
Current Penalty |
0.0 |
Initial Penalty |
13052.0 |
Final Order |
2022-02-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): Frequent and regular inspections of the job sites, materials, and equipment were not made by a competent person(s) designated by the employer: (a) On or about December 2, 2021, and at times prior thereto, safety and health inspections were not conducted by an individual who was aware of the safety and health standards and/or an individual who had sufficient authority to control or eliminate the hazard(s). |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19260760 A01 |
Issuance Date |
2022-01-27 |
Abatement Due Date |
2022-02-08 |
Current Penalty |
13052.0 |
Initial Penalty |
0.0 |
Final Order |
2022-02-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Each employee engaged in steel erection activity who is on a walking/ working surface with an unprotected side or edge was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems. (a) On or about December 2, 2021, and at times thereto, the controlling contractor Forge Building Company LLC did not ensure that its sub-contractor CCS General Construction LLC protected its employees while they worked at elevated heights on a metal roof structure and exposed to an approximate 17 foot fall hazard. |
|
|
345234850
|
1032500
|
2021-03-23
|
58 N KINGS RD., NAMPA, ID, 83687
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2021-03-23
|
Emphasis |
P: CTARGET, N: CTARGET
|
Case Closed |
2021-03-23
|
|
340212364
|
1032500
|
2014-12-22
|
289 E 7TH NORTH, REXBURG, ID, 83440
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-12-22
|
Emphasis |
L: FALL
|
Case Closed |
2015-04-27
|
Related Activity
Type |
Referral |
Activity Nr |
928760 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1021219 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2015-02-25 |
Abatement Due Date |
2015-03-23 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-04-13 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who was on a walking/working surface with an unprotected side or edge more than 15 feet* (4.6m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems: (a) Commercial Tire - On or about December 22, 2014, and at times prior thereto, employees were not protected from exterior falls while laying roof decking, which exposed them to the hazard of falling approximately 18 feet ground to eave. Note: Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260761 B |
Issuance Date |
2015-02-25 |
Abatement Due Date |
2015-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-04-13 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761: (a) On or about December 22, 2014, and at times prior thereto, employees demonstrated the inability to recognize and identify fall hazards and mitigate them with correct procedures to implement for fall protection. Note: Abatement certification IS required. |
|
|
332823749
|
1032500
|
2012-03-16
|
336 DEINHART LN, MCCALL, ID, 83638
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2012-03-16 |
Emphasis |
L: FALL |
Case Closed |
2012-09-27 |
Related Activity
Type |
Referral |
Activity Nr |
218923 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2012-07-09 |
Abatement Due Date |
2012-07-23 |
Current Penalty |
900.0 |
Initial Penalty |
1800.0 |
Final Order |
2012-07-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) South end of hangar: on 03/16/2012 and at times prior thereto, a worker walked underneath workers connecting flashing 21.5 feet overhead without wearing a hard hat. Note: Abatement certification IS NOT required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2012-07-09 |
Abatement Due Date |
2012-07-23 |
Current Penalty |
1500.0 |
Initial Penalty |
3000.0 |
Final Order |
2012-07-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet or less in width, the use of a safety monitoring system alone: a) South end of hangar: on 03/16/2012 and at times prior thereto, a worker was installing flashing from the hangar roof without fall protection. Note: Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260503 A01 |
Issuance Date |
2012-07-09 |
Abatement Due Date |
2012-08-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-07-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) South end of hangar: on 03/16/2012 and at times prior thereto, a worker exposed to a 21.5 fall was not trained to recognize fall hazards, inspect fall protection gear, wear fall protection gear, and avoid exposures to unsafe conditions. Note: Abatement certification IS required for this item. |
|
|