Name: | KNOW-HOW CONSTRUCTION SERVICES LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 05 Apr 2007 (18 years ago) |
Financial Date End: | 30 Apr 2025 |
Entity Number: | 194804 |
Place of Formation: | IDAHO |
File Number: | 194804 |
ZIP code: | 83639 |
County: | Owyhee County |
Principal Address: | 5997 ROLLING HILLS PL MARSING, ID 83639 |
Mailing Address: | 5997 ROLLING HILLS PL MARSING, ID 83639-8195 |
Name | Role | Address |
---|---|---|
JEFFERY F KINNEY | Agent | 5997 ROLLING HILLS PL, MARSING, ID 83639 |
Name | Role | Address | Appointed On |
---|---|---|---|
Jeff Kinney | Manager | 5997 ROLLING HILLS PL, MARSING, ID 83639 | 2021-03-04 |
Sharie Kinney | Manager | 5997 ROLLING HILLS PL, MARSING, ID 83639 | 2024-03-19 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005653516 | 2024-03-19 |
Annual Report | 0005233984 | 2023-05-09 |
Annual Report | 0004693878 | 2022-04-11 |
Annual Report | 0004196713 | 2021-03-04 |
Annual Report | 0003845806 | 2020-04-15 |
Annual Report | 0003500427 | 2019-05-01 |
Annual Report | 0001696305 | 2018-04-15 |
Annual Report | 0001696304 | 2017-04-17 |
Annual Report | 0001696303 | 2016-03-16 |
Annual Report | 0001696302 | 2015-04-22 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
334348919 | 1032500 | 2012-05-17 | ALLEY NORTH OF STATE ST BETWEEN 13TH & 14TH ST, BOISE, ID, 83702 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 357013 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2012-07-30 |
Abatement Due Date | 2012-07-31 |
Current Penalty | 880.0 |
Initial Penalty | 1760.0 |
Final Order | 2012-08-17 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a) Alley way located off 14th St, between State St and Washington St: On or about May 17, 2012 and at times prior thereto, an employee was installing pipe fitting onto a sewer main in an excavation ranging up to approximately 6.7 feet in depth with nearly vertical walls and only one section of vertical shoring in place. Note: Abatement certification IS required. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260652 C02 I |
Issuance Date | 2012-07-30 |
Abatement Due Date | 2012-07-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-08-17 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer. a) Alley way located off 14th St, between State St and Washington St: On or about May 17, 2012 and at times prior thereto, the employer had installed only one section of hydraulic Speed Shore vertical shoring to protect an employee in an approximate 6.7 foot deep trench. The tabulated data from the company states that 3 consecutive shores in a row will constitute a proper shoring system. Note: Abatement Certification IS required. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260651 C02 |
Issuance Date | 2012-07-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-08-17 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Alley way located off 14th St, between State St and Washington St: On or about May 17, 2012 and at times prior thereto, an employee was working in an approximate 6.7 foot deep trench without a ladder or ramp to provide safe means of egress. Note: Abatement certification is NOT required. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19261053 B04 |
Issuance Date | 2012-07-30 |
Abatement Due Date | 2012-07-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-08-17 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) Alley way located off 14th St, between State St and Washington St: On or about May 17, 2012 and at times prior thereto, the employer used the ladder, being placed in the excavation for means of egress, as a prop to aid in jumping over the trench. Note: Abatement certification IS required. |
Inspection Type | Referral |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2009-03-12 |
Emphasis | N: TRENCH, S: COMMERCIAL CONSTR, S: POWERED IND VEHICLE, S: STRUCK-BY, S: TRENCHING |
Case Closed | 2010-03-12 |
Related Activity
Type | Referral |
Activity Nr | 200248011 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260652 A01 |
Issuance Date | 2009-03-17 |
Abatement Due Date | 2009-03-20 |
Current Penalty | 150.0 |
Initial Penalty | 1500.0 |
Contest Date | 2009-04-14 |
Final Order | 2010-03-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260020 B01 |
Issuance Date | 2009-03-17 |
Abatement Due Date | 2009-04-21 |
Contest Date | 2009-04-14 |
Final Order | 2010-03-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 01 |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5676937408 | 2020-05-12 | 1087 | PPP | 5997 ROLLING HILLS PL, MARSING, ID, 83639-8195 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|